HomeMy WebLinkAboutOWTS Design - REVISED 09.18.2024129 Cains Lane Carbondale, CO 81623 970.309.5259 carla.ostberg@gmail.com September 26, 2024 Project No. C1882 Lindsay Gurley ljgurley@gmail.com Subsurface Investigation and Onsite Wastewater Treatment System Design 2-Bedroom Residence 1319 CR 127 Garfield County, Colorado Lindsay, CBO Inc. performed a subsurface investigation and completed an onsite wastewater treatment system (OWTS) design for the subject residence. The 35-acre property is located outside of Glenwood Springs, in an area where OWTSs are necessary. The previous location and configuration of the soil treatment area (STA) has been modified from our original design documents dated May 24, 2024 to meet setbacks to the existing and new portions of the water line. Previous design documents should be discarded and replaced with these design documents dated September 26, 2024. Legal Description: Section: 28 Township: 6 Range: 89 A TR IN NW1/4 AND NWNE 35 ACRES Parcel ID: 2185-282-00-024 SITE CONDITIONS The property is currently developed with a 3-bedroom residence. The residence has been removed and replaced with a 2-bedroom residence with a smaller footprint. The permit (enclosed) was provided by Garfield County Community Development Department. The subject OWTS consists of one 1000-gallon, two-compartment concrete septic tank followed by a STA comprised of 26 ‘Standard’ Infiltrator® chambers for a total of 487.5 square feet of infiltrative area. Individual Sewage Disposal System (ISDS) Permit 1717 documents the system installation. The system was sized to accommodate 3 bedrooms. The permit received final approval on October 25, 1989. While the septic tank is located on the site plan, it is difficult to determine the exact location of the existing STA. There does not appear to be sufficient space on the property to accommodate an STA of the size indicated on the original permit. We speculate there could be trenches on the hillside to the south based on the direction of the piping exiting the septic tank. However, the hillside is extremely steep with limited space and the water line also runs in that direction. The only other potential location for the STA is the driveway. Attempts to camera the existing sewer line when the OWTS was in use were unproductive. It is possible the existing STA encroached on setbacks to the water line and/or the foundation of the previous residence. The residence is served by a community water system. The water line was recently located and a tap created in the driveway. A new portion of water line was installed from the tap into the southwest side of the new residence. We have approximated the existing water line path down the hillside to the south. The water line must be at least 25-feet from the proposed soil treatment area (STA), 10-feet from the proposed septic tank, and 5-feet from the proposed sewer line. Page 2 The proposed STA location is relatively flat and parallels the house to the east. This is the only area that can accommodate the STA while meeting the setbacks to the water line. The house foundation is a shallow crawl space; however, the required 20-foot setback cannot be met without dropping over the steep hillside to the east 1. The STA will not come closer to the foundation than 10-feet. This reduction in setback will have no adverse impacts on the foundation or functioning of the STA. The depth of the foundation is relatively shallow, approximately 4-feet in depth (2-feet below current native grade). The STA will be placed downgradient of the foundation to the east. The STA will be pressure dosed, applying approximately 50 gallons of water per dose to each zone of the STA, sprayed evenly throughout the field which should allow the soils to accept the effluent without creating saturated conditions. Pressure distribution also allows soils resting time between doses. Additionally, roof drains and perimeter drains will be utilized to direct storm water away from the house and OWTS. View of foundation looking southwest View of foundation and house looking southwest While there will be an encroachment on the foundation setback, the site is constrained, and the new residence will have only 2-bedrooms where the previous residence had 3-bedrooms. Also, the setback to the water line will be maintained by the new OWTS where previously this setback was not met. There should be no traffic or staging of material over the future STA site to avoid compaction of soils prior to construction of the STA. 1 Garfield County On-Site Wastewater Treatment System Regulation 43. Table 7-1 Note: “For repair or upgrading of existing OWTS where the size of lot precludes adherence to these distances, a repaired OWTS must not be closer to setback features than the existing OWTS, as reviewed and approved by the local public health agency.” In this case, the encroachment on the water line is being remedied while the setback to foundation will be less. Page 3 SUBSURFACE The subsurface was investigated by Kumar and Associates, Project No. 21-7-112 and is documented in a report dated February 5, 2021 (enclosed). One soil boring was drilled in the driveway near the existing house foundation and was sampled for the evaluation. The boring consisted of 6-inches of base (aggregate), underlain by fill to 3-feet, underlain by gravel and sand to 6-feet, underlain by sandstone bedrock to a maximum depth explored of 16.5-feet. With the presence of bedrock at 6-feet and limited space available on the property for construction of the STA, we are proposing a pressure-dosed, over-excavated, unlined sand filter with 3-feet of sand filter material (Secondary Sand). A long term acceptance rate (LTAR) of 0.8 gallons per square foot will be used to design the OWTS. DESIGN SPECIFICATIONS The existing septic tank will be abandoned by pumping the tank and removing it. The existing STA will be abandoned in place (location unknown). Design Calculations: Average Design Flow = 75 GPD x 2 people/bedroom x 2 Bedrooms = 300 GPD LTAR = 0.8 GPD/SF 300 GPD / 0.8 GPD/SF = 375 SF The OWTS design is based on 2-bedrooms. An average daily wastewater flow of 300 GPD will be used. For the purposes of this OWTS design, Benchmark Elevation has been established as 100’ (Finished Floor). CBO Inc. should be notified of any discrepancies or problems with grade elevations of proposed components during installation of the OWTS. OWTS Component Minimum Elevation Primary Tank Inlet Invert Approximate horizontal distance 31’ / min. 2% fall / min. 7.75” fall Automatic Distributing Valve Approximate horizontal distance 50’ / min. 1% rise / min. 6.25” rise Infiltrative Surface Approximate horizontal distance 5’ / min. 1% fall to STA / min. 0.625” fall *Elevations are based upon standard OWTS installation practices. Component elevations may change during installation due to site conditions. Minimum grade refers to piping between components. The 4-inch SDR-35 sewer line exiting the residence must have a double-sweep clean out and a minimum 2% grade to the septic tank. Any area subject to traffic must be minimum Schedule 40 sewer line. The system installation will include a 1000-gallon, two-compartment Valley Precast concrete septic with an Orenco® Biotube Pump Vault and an Orenco® PF3005 pump in the second compartment. The floats should be set to dose approximately 54 gallons each pump cycle, allowing approximately 5 gallons of drain back. The control panel for the pump must be located within line of sight of the septic tank. An electrician will be responsible for wiring the pumping system and the contractor will be responsible for connecting the plumbing. This office should be contacted for start up of the system to verify its functioning and to perform a squirt test prior to use of the system. Page 4 Pump Table Dose Range Max = 80 gal. (300 GPD x 25% + 5 gal drain back) Min. 29 gal. (6 gal x 4) + 5 gal drain back Dose Setting 54 gallons/dose 5 gallons drain back (50’ / 1.5” diameter pump line) Float Separation 1000 gallon two-compartment Valley Precast concrete septic tank 8” on/off float separation Pump Criteria 17.6 gallons per minute (GPM) 15.3 feet total dynamic head (TDH) Effluent will be pumped through a 1.5-inch diameter pump line from the pump chamber to an Orenco® automatic distributing valve (ADV), model 6402. This pump line must have a minimum 1% grade for proper drain back into the tank after each pump cycle. The ADV must be placed at a high point in the system in an insulated riser with access from grade. Screened rock must be placed below the ADV to support the ADV and to assure the clear pipes exiting the ADV remain visible for future inspection and maintenance. Effluent will be pressure dosed to through 1.5-inch diameter distribution lines to two 7’ x 26’ 10” beds. A minimum of 3-feet of sand filter material will be installed in the over-excavated footprint. Sand filter material must be clean, coarse sand, all passing a screen having four meshes to the inch. The sand must have an effective size between 0.15 and 0.60 mm. The uniformity coefficient must be 7.0 or less. Material meeting ASTM 33, for concrete sand, with three percent or less fines passing 200 mesh sieve may be used. A gradation of the sand media must be submitted to this office prior to obtaining the sand. The ends and downhill sides of the sand filters (inside the excavation and outside of the sand filters) must be lined with a 30 mil PVC liner to prevent lateral migration of effluent toward the steep hillside. Laterals must be 1.5-inches in diameter with 5/32-inch diameter orifices facing down, spaced 2-feet on center, installed on the GeoMat™ with the filter fabric over the laterals. Laterals should be placed 2-feet from the edges of the bed with 3.0-feet between the laterals. Laterals will be connected with 1.5-inch diameter level manifolds. Two 39” wide GeoMats™ must be placed on the 7-foot wide beds. All material associated with the GeoMat™ installation must be proprietary products associated with the GeoMat™, including orifice shields and geotextile fabric. Manufacturer instructions must be followed regarding installation of the GeoMat™. Each 1.5-inch diameter lateral must end in a sweeping ell facing up with a ball valve for flushing. Valves should be placed in a 10-inch sprinkler box for access. Laterals must be covered by a soil separation fabric and at least 1-foot of topsoil or other suitable soil able to support vegetative growth. There shall be no cobble-sized (>2.5”) or greater rock in final cover over the GeoMat™. Inspection ports must be placed at each corner of each bed. Ports may be cut to grade and covered with a valve box for access. COMPONENT SPECIFICATIONS The component manufacturers are typical of applications used by contractors and engineers in this area. CBO Inc. must approve alternative components prior to installation of the OWTS. Requests must be submitted, in writing, to our office for approval prior to installation. Component technical data sheets are available upon request. Page 5 COMPONENT MANUFACTURER MODEL NO. COMMENTS Septic Tank Valley Precast Item # 1000T-2CP-HH 1000-gallon, two- compartment concrete septic tank with high head pump Pump Orenco® PF300511 ½ HP 120 Volt Biotube ProPak Pump Package Orenco® BPP30DD Vault, Filter, Control Panel (demand dose) Tank Risers and Lids Orenco® Double-walled PVC Risers and Lids (24” diameter) ADV Orenco® V6402A 1.5” Inlet and Outlets ADV Riser and Lid Orenco® Double-walled PVC Risers and Lids (30” diameter) Flushing Assembly Orenco® 1.5” diameter (2) 45° or 90° long sweep only (4 total) GeoMat™ GeoMatrix Systems, LLC 108 linear feet 39” wide GeoMat™ and 48 orifice shields PVC Pond Liner 30 MIL 68’ long, 3’ deep Construction must be according to the jurisdiction’s adopted On-Site Wastewater Treatment System Regulations, the OWTS Permit, and this design. PERMIT APPLICATION INSTRUCTIONS An OWTS Permit Application must be submitted to Garfield County Environmental Health Department. https://www.garfield-county.com/environmental-health/filesgcco/sites/16/OWTS-Application-Complete- Packet-Dec.-2019.pdf. If the OWTS Permit Application will be submitted with a Building Permit Application, it should be submitted directly to Garfield County Building Department. All questions regarding permit submission can be directed to Garfield County Environmental Health Department, 970-945-6614 x8150. INSTALLATION CONTRACTOR CBO Inc. expects that the installer be experienced and qualified to perform the scope of work outlined in this design. The installer must review this design thoroughly and coordinate with our office in advance of installation. Any additional conditions in this design or county permit must be completed and documented prior to final approval of the OWTS installation. Communication between the installer and this office is expected throughout the installation. INSTALLATION OBSERVATIONS CBO Inc. must view the OWTS during construction. The OWTS observation should be performed before backfill, after placement of OWTS components. Septic tanks, distribution devices, pumps, dosing siphons, and other plumbing, as applicable, must also be observed. CBO Inc. should be notified 48 hours in advance to observe the installation. In an effort to improve the accuracy of the record drawing, we request that the installer provide a sketch of the installation, including path of the sewer lines, water line installation (if applicable), septic tank location, STA location, and measurements from building corners or another fixed Page 6 objects on the property. This sketch is most easily provided on Sheet W2.0 of the OWTS Design Packet. Photographs of the installation and final cover are also requested to supplement our installation documentation. REVEGETATION REQUIREMENTS An adequate layer of good quality topsoil capable of supporting revegetation shall be placed over the entire disturbed area of the OWTS installation. A mixture of native grass seed that has good soil stabilizing characteristics (but without taproots), provides a maximum transpiration rate, and competes well with successional species. No trees or shrubs, or any vegetation requiring regular irrigation shall be placed over the STA. Until vegetation is reestablished, erosion and sediment control measures shall be implemented and maintained on site. The owner of the OWTS shall be responsible for maintaining proper vegetation cover. OPERATION INFORMATION AND MAINTENANCE The property owner shall be responsible for the operation and maintenance of each OWTS servicing the property. The property owner is responsible for maintaining service contracts for manufactured units, alternating STAs, and any other components needing maintenance. Geo-fabrics or plastics should not be used over the STA. No heavy equipment, machinery, or materials should be placed on the backfilled STA. Machines with tracks (not wheels) should be used during construction of the STA for better weight distribution. Livestock should not graze on the STA. Plumbing fixtures should be checked to ensure that no additional water is being discharged to OWTS. For example, a running toilet or leaky faucet can discharge hundreds of gallons of water a day and harm a STA. If an effluent filter or screen has been installed in the OWTS, we recommend this filter or screen be cleaned annually, or as needed. If the OWTS consists of a pressurized pump system, we recommend the laterals be flushed annually, or as needed. The homeowner should pump the septic tank every two years, or as needed gauged by measurement of solids in the tank. Garbage disposal use should be minimized, and non-biodegradable materials should not be placed into the OWTS. Grease should not be placed in household drains. Loading from a water softener should not be discharged into the OWTS. No hazardous wastes should be directed into the OWTS. Mechanical room drains should not discharge into the OWTS. The OWTS is engineered for domestic waste only. ADDITIONAL CONSTRUCTION NOTES If design includes a pump, weep holes must be installed to allow pump lines to drain to minimize risk of freezing. The pump shall have an audible and visual alarm notification in the event of excessively high- water conditions and shall be connected to a control breaker separate from the high-water alarm breaker and from any other control system circuits. The pump system shall have a switch so the pump can be manually operated. Excavation equipment must not drive in the excavation of the STA due to the potential to compact soil. Extensions should be placed on all septic tank components to allow access to them from existing grade. Backfill over the STA must be uniform and granular with no material greater than minus 3-inch. LIMITS: The design is based on information submitted. If soil conditions encountered are different from conditions described in report, CBO Inc. should be notified. All OWTS construction must be according to the county regulations. Requirements not specified in this report must follow applicable county regulations. The contractor should have documented and demonstrated knowledge of the requirements and regulations of the county in which they are working. Licensing of Systems Contractors may be required by county regulation. Page 7 Please call with questions. Sincerely, CBO Inc. Carla Ostberg, MPH, REHS Pump Selection for a Pressurized System - Single Family Residence Project 1319 CR 127 Parameters Discharge Assembly Size Transport Length Before Valve Transport Pipe Class Transport Line Size Distributing Valve Model Transport Length After Valve Transport Pipe Class Transport Pipe Size Max Elevation Lift Manifold Length Manifold Pipe Class Manifold Pipe Size Number of Laterals per Cell Lateral Length Lateral Pipe Class Lateral Pipe Size Orifice Size Orifice Spacing Residual Head Flow Meter 'Add-on' Friction Losses 1.25 50 40 1.50 6402 5 40 1.50 3 20 40 1.25 4 25 40 1.25 5/32 2 5 None 0 inches feet inches feet inches feet feet inches feet inches inches feet feet inches feet Calculations Minimum Flow Rate per Orifice Number of Orifices per Zone Total Flow Rate per Zone Number of Laterals per Zone % Flow Differential 1st/Last Orifice Transport Velocity Before Valve Transport Velocity After Valve 0.68 26 17.6 2 0.9 2.8 2.8 gpm gpm % fps fps Frictional Head Losses Loss through Discharge Loss in Transport Before Valve Loss through Valve Loss in Transport after Valve Loss in Manifold Loss in Laterals Loss through Flowmeter 'Add-on' Friction Losses 2.2 0.9 3.7 0.1 0.2 0.1 0.0 0.0 feet feet feet feet feet feet feet feet Pipe Volumes Vol of Transport Line Before Valve Vol of Transport Line After Valve Vol of Manifold Vol of Laterals per Zone Total Vol Before Valve Total Vol After Valve 5.3 0.5 1.6 3.9 5.3 5.9 gals gals gals gals gals gals Minimum Pump Requirements Design Flow Rate Total Dynamic Head 17.6 15.3 gpm feet 0 5 10 15 20 25 30 35 400 50 100 150 200 250 300 Net Discharge (gpm) PumpData PF3005 High Head Effluent Pump 30 GPM, 1/2HP 115/230V 1Ø 60Hz, 200V 3Ø 60Hz PF3007 High Head Effluent Pump 30 GPM, 3/4HP 230V 1Ø 60Hz, 200/460V 3Ø 60Hz PF3010 High Head Effluent Pump 30 GPM, 1HP 230V 1Ø 60Hz, 200/460V 3Ø 60Hz PF3015 High Head Effluent Pump 30 GPM, 1-1/2HP 230V 1Ø 60Hz, 200/230/460V 3Ø 60Hz Legend System Curve: Pump Curve: Pump Optimal Range: Operating Point: Design Point: 5020 County Road 154 Glenwood Springs, CO 81601 phone: (970) 945-7988 fax: (970) 945-8454 email: kaglenwood@kumarusa.com www.kumarusa.com Office Locations: Denver (HQ), Parker, Colorado Springs, Fort Collins, Glenwood Springs, and Summit County, Colorado SUBSOIL STUDY FOR FOUNDATION DESIGN PROPOSED RESIDENCE 1319 COUNTY ROAD 127 (MOUNTAIN SPRINGS ROAD) GARFIELD COUNTY, COLORADO PROJECT NO. 21-7-112 FEBRUARY 5, 2021 PREPARED FOR: LINDSAY GURLEY 1319 COUNTY ROAD 127 GLENWOOD SPRINGS, COLORADO 81601 lindsay@lindsaygurley.com Kumar & Associates, Inc. ® Project No. 21-7-112 TABLE OF CONTENTS PURPOSE AND SCOPE OF STUDY ....................................................................................... - 1 - PROPOSED CONSTRUCTION ................................................................................................ - 1 - SITE CONDITIONS ................................................................................................................... - 1 - PROJECT SITE GEOLOGY ...................................................................................................... - 2 - FIELD EXPLORATION ............................................................................................................ - 2 - SUBSURFACE CONDITIONS ................................................................................................. - 2 - FOUNDATION BEARING CONDITIONS .............................................................................. - 3 - DESIGN RECOMMENDATIONS ............................................................................................ - 3 - FOUNDATIONS .................................................................................................................... - 3 - FOUNDATION AND RETAINING WALLS ....................................................................... - 4 - FLOOR SLABS ...................................................................................................................... - 5 - UNDERDRAIN SYSTEM ..................................................................................................... - 6 - SITE GRADING ..................................................................................................................... - 6 - SURFACE DRAINAGE ......................................................................................................... - 7 - LIMITATIONS ........................................................................................................................... - 7 - FIGURE 1 - LOCATION OF EXPLORATORY BORING FIGURE 2 – LOG OF EXPLORATORY BORING FIGURE 3 - SWELL-CONSOLIDATION TEST RESULTS FIGURE 4 - GRADATION TEST RESULTS TABLE 1- SUMMARY OF LABORATORY TEST RESULTS Kumar & Associates, Inc. ® Project No. 21-7-112 PURPOSE AND SCOPE OF STUDY This report presents the results of a subsoil study for a proposed residence to be located at 1319 County Road 127 (Mountain Springs Road), Garfield County, Colorado. The project site is shown on Figure 1. The purpose of the study was to develop recommendations for the foundation design. The study was conducted in accordance with our agreement for geotechnical engineering services to Lindsay Gurley dated January 7, 2021. A field exploration program consisting of an exploratory boring was conducted to obtain information on the subsurface conditions. Samples of the subsoils and bedrock obtained during the field exploration were tested in the laboratory to determine their classification, compressibility or swell and other engineering characteristics. The results of the field exploration and laboratory testing were analyzed to develop recommendations for foundation types, depths and allowable pressures for the proposed building foundation. This report summarizes the data obtained during this study and presents our conclusions, design recommendations and other geotechnical engineering considerations based on the proposed construction and the subsurface conditions encountered. PROPOSED CONSTRUCTION The existing residence will be removed and the new residence built in its place. The proposed residence will be a one or two story structure with an attached garage. Ground floor will be slab- on-grade or structural over crawlspace. Grading for the structure is assumed to be relatively minor with cut depths between about 3 to 6 feet. We assume relatively light foundation loadings, typical of the proposed type of construction. When building location, grading and loading information have been developed, we should be notified to re-evaluate the recommendations presented in this report. SITE CONDITIONS There is an existing one-story modular residence on the subject site. The site is accessed by an existing gravel driveway from the southwest. Topography at the site consists of valley side with moderate to steep slopes down to the southeast. There is about 6 feet of elevation difference across the proposed building area. The site has undergone cut and fill grading for the existing - 2 - Kumar & Associates, Inc. ® Project No. 21-7-112 development including possible fill in the lower part of the building site. Vegetation at the site consists of native grass and weeds, mature scrub oak, and scattered conifers. PROJECT SITE GEOLOGY The project site is underlain by the Permian and Pennsylvanian-age Maroon Formation. The Maroon Formation is a fine to coarse grained sandstone with interbedded claystone and conglomerate. The bedding dip of the Maroon Formation in the area of the subject site is about 50 degrees down to the southwest. A thin layer of colluvial soil overlies the Maroon Formation at the subject site in some areas. FIELD EXPLORATION The field exploration for the project was conducted on January 27, 2021. One exploratory boring was drilled at the location shown on Figure 1 to evaluate the subsurface conditions. The boring was advanced with 4 inch diameter continuous flight augers powered by a truck-mounted CME-45B drill rig. The boring was logged by a representative of Kumar & Associates, Inc. Samples of the subsoils were taken with 1⅜ inch and 2 inch I.D. spoon samplers. The samplers were driven into the subsurface materials at various depths with blows from a 140 pound hammer falling 30 inches. This test is similar to the standard penetration test described by ASTM Method D-1586. The penetration resistance values are an indication of the relative density or consistency of the subsoils and hardness of the bedrock. Depths at which the samples were taken and the penetration resistance values are shown on the Log of Exploratory Boring, Figure 2. The samples were returned to our laboratory for review by the project engineer and testing. SUBSURFACE CONDITIONS A graphic log of the subsurface conditions encountered at the site is shown on Figure 2. The subsoils consist of about ½ foot of road base overlying about 2½ feet of previously placed fill material consisting of sandy clay with scattered gravel underlain by about 3 feet of dense, silty clayey gravel and sand. Very hard sandstone bedrock of the Maroon Formation was encountered at a depth of 6 feet down to the maximum depth explored of 16½ feet. Drilling in the bedrock with auger equipment was difficult due to the hardness and drilling refusal was encountered in the deposit at a depth of 16½ feet. - 3 - Kumar & Associates, Inc. ® Project No. 21-7-112 Laboratory testing performed on samples obtained from the boring included natural moisture content and density and gradation analyses. Results of swell-consolidation testing performed on a relatively undisturbed drive sample of the colluvial soils, presented on Figure 3, indicate low compressibility under conditions of loading and wetting and a minor expansion potential when wetted under a 1,000 psf surcharge. Results of gradation analyses performed on a small diameter drive sample (minus ¾-inch fraction) of the granular fill soils are shown on Figure 4. The laboratory testing is summarized in Table 1. No free water was encountered in the boring at the time of drilling and the subsoils were slightly moist. FOUNDATION BEARING CONDITIONS At assumed excavation depths, we expect the subgrade will vary from the silty clayey gravel and sand soils to bedrock of the Maroon Formation. The silty clayey gravel and sand soils possess moderate bearing capacity and low settlement potential. The expansion potential shown in the swell-consolidation test performed on a sample of the gravel and sand is likely an anomaly and does not warrant mitigation. The bedrock of the Maroon Formation possesses moderate to high bearing capacity and low settlement potential. Spread footings appear feasible for foundation support of the residence with a minor risk of differential settlement. The risk of settlement is due to the variable bearing conditions from assumed soil to rock. A lower risk alternative would be to bear the footings entirely on the bedrock of the Maroon Formation or on compacted structural fill extended down to the bedrock. The compacted structural fill can consist of the on-site natural soils devoid of vegetation, topsoil, and oversized rock (plus 6-inch size). Existing fill and disturbed soils from previous development should be removed from below the building area. DESIGN RECOMMENDATIONS FOUNDATIONS Considering the subsurface conditions encountered in the exploratory boring and the nature of the proposed construction, we recommend the building be founded with spread footings bearing on the natural granular soils or bedrock. - 4 - Kumar & Associates, Inc. ® Project No. 21-7-112 The design and construction criteria presented below should be observed for a spread footing foundation system. 1) Footings placed on the undisturbed natural granular soils or bedrock should be designed for an allowable bearing pressure of 2,500 psf. Based on experience, we expect settlement of footings designed and constructed as discussed in this section will be about 1 inch or less. 2) The footings should have a minimum width of 16 inches for continuous walls and 2 feet for isolated pads. 3) Exterior footings and footings beneath unheated areas should be provided with adequate soil cover above their bearing elevation for frost protection. Placement of foundations at least 36 inches below exterior grade is typically used in this area. 4) Continuous foundation walls should be reinforced top and bottom to span local anomalies such as by assuming an unsupported length of at least 12 feet. Foundation walls acting as retaining structures should also be designed to resist lateral earth pressures as discussed in the "Foundation and Retaining Walls" section of this report. 5) All existing fill, debris, topsoil and any loose or disturbed soils should be removed and the footing bearing level extended down to the relatively dense natural granular soils or hard bedrock. The exposed soils in footing area should then be moistened and compacted. 6) A representative of the geotechnical engineer should observe all footing excavations prior to concrete placement to evaluate bearing conditions. FOUNDATION AND RETAINING WALLS Foundation walls and retaining structures which are laterally supported and can be expected to undergo only a slight amount of deflection should be designed for a lateral earth pressure computed on the basis of an equivalent fluid unit weight of at least 50 pcf for backfill consisting of the on-site soils and well broken bedrock and at least 45 pcf for backfill consisting of imported granular materials. Cantilevered retaining structures which are separate from the residence and can be expected to deflect sufficiently to mobilize the full active earth pressure condition should be designed for a lateral earth pressure computed on the basis of an equivalent fluid unit weight of at least 45 pcf for backfill consisting of the on-site soils and well broken bedrock and at least 40 pcf for backfill consisting of imported granular materials. - 5 - Kumar & Associates, Inc. ® Project No. 21-7-112 All foundation and retaining structures should be designed for appropriate hydrostatic and surcharge pressures such as adjacent footings, traffic, construction materials and equipment. The pressures recommended above assume drained conditions behind the walls and a horizontal backfill surface. The buildup of water behind a wall or an upward sloping backfill surface will increase the lateral pressure imposed on a foundation wall or retaining structure. An underdrain should be provided to prevent hydrostatic pressure buildup behind walls. Backfill should be placed in uniform lifts and compacted to at least 90% of the maximum standard Proctor density at a moisture content near optimum. Backfill placed in pavement and walkway areas should be compacted to at least 95% of the maximum standard Proctor density. Care should be taken not to overcompact the backfill or use large equipment near the wall, since this could cause excessive lateral pressure on the wall. Some settlement of deep foundation wall backfill should be expected, even if the material is placed correctly, and could result in distress to facilities constructed on the backfill. The lateral resistance of foundation or retaining wall footings will be a combination of the sliding resistance of the footing on the foundation materials and passive earth pressure against the side of the footing. Resistance to sliding at the bottoms of the footings can be calculated based on a coefficient of friction of 0.45. Passive pressure of compacted backfill against the sides of the footings can be calculated using an equivalent fluid unit weight of 375 pcf. The coefficient of friction and passive pressure values recommended above assume ultimate soil strength. Suitable factors of safety should be included in the design to limit the strain which will occur at the ultimate strength, particularly in the case of passive resistance. Fill placed against the sides of the footings to resist lateral loads should be compacted to at least 95% of the maximum standard Proctor density at a moisture content near optimum. FLOOR SLABS The natural on-site soils, exclusive of topsoil, are suitable to support lightly loaded slab-on-grade construction. To reduce the effects of some differential movement, floor slabs should be separated from all bearing walls and columns with expansion joints which allow unrestrained vertical movement. Floor slab control joints should be used to reduce damage due to shrinkage cracking. The requirements for joint spacing and slab reinforcement should be established by the designer based on experience and the intended slab use. A minimum 4 inch layer of free- draining gravel should be placed beneath basement level slabs to facilitate drainage. This - 6 - Kumar & Associates, Inc. ® Project No. 21-7-112 material should consist of minus 2-inch aggregate with at least 50% retained on the No. 4 sieve and less than 2% passing the No. 200 sieve. All fill materials for support of floor slabs should be compacted to at least 95% of maximum standard Proctor density at a moisture content near optimum. Required fill can consist of the on- site natural granular soils devoid of vegetation, topsoil and oversized rock. UNDERDRAIN SYSTEM Although free water was not encountered during our exploration, it has been our experience in the area and where bedrock is shallow that local perched groundwater can develop during times of heavy precipitation or seasonal runoff. Frozen ground during spring runoff can create a perched condition. We recommend below-grade construction, such as retaining walls, crawlspace and basement areas, be protected from wetting and hydrostatic pressure buildup by an underdrain system. The drains should consist of rigid perforated PVC drainpipe placed in the bottom of the wall backfill surrounded above the invert level with free-draining granular material. The drain should be placed at each level of excavation and at least 1 foot below lowest adjacent finish grade and sloped at a minimum ½% to a suitable gravity outlet. Free-draining granular material used in the underdrain system should contain less than 2% passing the No. 200 sieve, less than 50% passing the No. 4 sieve and have a maximum size of 2 inches. The drain gravel backfill should be at least 1½ feet deep and covered with filter fabric such as Mirafi 140N or 160N. SITE GRADING The risk of construction-induced slope instability at the site appears low provided the building is located in the existing graded pad area as planned and cut and fill depths are limited. We assume the cut depths for the lower foundation level will not exceed about 2 feet. Fills should be limited to about 8 feet deep, especially at the downhill side of the residence where the slope steepens. Embankment fills should be compacted to at least 95% of the maximum standard Proctor density near optimum moisture content. Prior to fill placement, the subgrade should be carefully prepared by removing all vegetation and topsoil and compacting to at least 95% of the maximum standard Proctor density. The fill should be benched into the portions of the hillside exceeding 20% grade. - 7 - Kumar & Associates, Inc. ® Project No. 21-7-112 Permanent unretained cut and fill slopes should be graded at 2 horizontal to 1 vertical or flatter and protected against erosion by revegetation or other means. This office should review site grading plans for the project prior to construction. SURFACE DRAINAGE The following drainage precautions should be observed during construction and maintained at all times after the residence has been completed: 1) Inundation of the foundation excavations and underslab areas should be avoided during construction. 2) Exterior backfill should be adjusted to near optimum moisture and compacted to at least 95% of the maximum standard Proctor density in pavement and slab areas and to at least 90% of the maximum standard Proctor density in landscape areas. 3) The ground surface surrounding the exterior of the building should be sloped to drain away from the foundation in all directions. We recommend a minimum slope of 12 inches in the first 10 feet in unpaved areas and a minimum slope of 3 inches in the first 10 feet in paved areas. Free-draining wall backfill should be covered with filter fabric and capped with about 2 feet of the on-site finer graded soils to reduce surface water infiltration. 4) Roof downspouts and drains should discharge well beyond the limits of all backfill. 5) Landscaping which requires regular heavy irrigation should be located at least 5 feet from foundation walls. LIMITATIONS This study has been conducted in accordance with generally accepted geotechnical engineering principles and practices in this area at this time. We make no warranty either express or implied. The conclusions and recommendations submitted in this report are based upon the data obtained from the exploratory boring drilled at the location indicated on Figure 1, the proposed type of construction and our experience in the area. Our services do not include determining the presence, prevention or possibility of mold or other biological contaminants (MOBC) developing in the future. If the client is concerned about MOBC, then a professional in this special field of practice should be consulted. Our findings include interpolation and extrapolation of the subsurface conditions identified at the exploratory boring and variations in the subsurface Kumar & Associates Kumar & Associates Kumar & Associates Kumar & Associates TABLE 1 SUMMARY OF LABORATORY TEST RESULTS Project No. 21-7-112 SAMPLE LOCATION NATURAL MOISTURE CONTENT NATURAL DRY DENSITY GRADATION PERCENT PASSING NO. 200 SIEVE ATTERBERG LIMITS UNCONFINED COMPRESSIVE STRENGTH SOIL TYPE BORING DEPTH GRAVEL SAND LIQUID LIMIT PLASTIC INDEX (%) (%) (ft) (%) (pcf) (%) (%) (psf) 1 1 7.1 3 45 52 32 16 Very Sandy Clay with Scattered Gravel (Fill) 4 4.8 119 35 Silty Clayey Gravel and Sand y GARFIELD COUNTY BUILDING AND SANITATION DEPARTMENT 109 8th Street Suite 303 Glenwood Springs, Colorado 81801 Phone (303) 945 -8212 This does not constitute INDIVIDUAL SEWAGE DISPOSAL PERMIT NQ a building or use permit. 11 Owner Fb} xt Jones System Location A parcel of land situated in the NW 1/4 and tJ )J2 T9I'. 1/4 Sec, 2R, T6S, RR941 Licensed Installer Ib11 HAIlat1 Conditional Construction approval is hereby g for a 000 gallon US E 2.6 ear 3 X 4,c ei. r ln y /f r ct P" z4 1i (s =Septic Tank or _Aerated treatment unit. C ¢ btired)teAbsorptionarea (or dispersal area) computed as follows: Perc rate of one inch in J0 minutes requires a minimum of 9j,Gsq. ft. of absorption area per bedroom. 3 ` /SThereforetheno. of bedrooms _x sq.ft . minimum requirement = a total of 4/..Lq. ft. of absorption area. May we suggest 7 , .o .r r, . i F DDU le ii ie ?'b lea Home / 3 !/ % ` ; E!l C fec 2.0 f /Uc < % if7 l c r /k /Nb cF/ r4 Date x 3k79 C e e c) (- 7 Inspector '? 3 v r-/ c ` 9 79. FINAL APPROVAVOF SYSTEM:1. % 1 + ! No system shall be deemed to be in compliance with the Sewage Disposal Laws until the assembled system is approved prior to cover• ing any party' Septic Tank access for inspection and cleaning within 12" of ground surface or aerated access ports above groundsurface. IPropermaterialsandassembly. .Th /GR.r- f 7 c 1i Co0?a2,r1 Trade name of septic tank or aerated treatment unit. /tin / 0 q,1 • airAdequateabsorption (or dispersal) area. 2 (o 2N9 4 6.1 o - 4rr gad = 4D( Adequate compliance with permit requirements. y f•4 Adequate compliance with County and State regulations /requirements. Other Date_ ., /C — 5'^ O ` f _Inspector SLu. -2MD RETAIN WITH RECEIPT RECORDS AT CONSTRUCTION SITE CONDITIONS: 1. All Installation must comply with all requirements of the Colorado State Board of Health Individual Sewage Disposal SystemsChapter25, Article 10 C.R.S. 1973, Revised 1984. 2. This permit is valid only for connection to structures which have fully complied with County zoning and building requirements. Connection to or use with any dwelling or structures not approved by the Building and Zoning office shall automatically be a violation of a requirement of the permit and cause for both legal action and revocation of the permit. 3. Any person who constructs, alters, or installs an Individual sewage disposal system in a manner which involves a knowing and material variation from the terms or specifications contained in the application of permit commits a Class I, Petty Offense500.00 fine — 6 months in Jail or both.). Applicant: Green Copy Department: Pink Copy Application INDIVIDUAL SEWAGE DISPOS:L SYSTEM APPLICATION Approval by OWNER 46;g76 orc%S County Official: ADDRESS Sa Ao l0 6405 do/ PHONE 9 7nec CONTRACTOR MO/ ADDRESS OC 4 2 c ,<± C&.s 6WcVPHoNE 9W/S- 6e 3( /PERMIT REQUEST FOR: b} New Installation Alteration RepairAttachseparatesheetsorreportshowingentireareawithrespecttosurrounding areas,topography of area, habitable building, location of potable water wells, soil percolationtestholes, soil profiles in test holes. See page 4.) LOCATION OF PROPOSED FACILITY: County 6 c66'ZD Near what City of Town C5keduideu9 S //t /,t/65 Lot Size 3S.00 /96W Legal Description /9 %ice. F /ay.d TIare:4 iv Tie l/Gt/J Ae/D 4/t4a <Sec. t, 00.s, 2.19 Wofrme eve WASTES TYPE:54 Dwelling Transient Use Commercial or Institutional Non- domestic Wastes Other - Describe BUILDING OR SERVICE TYPE: A.Ade& G. / /de /1/00 /L4 Number of bedrooms 3 Number of persons 2 Garbage grinder NO Automatic washer Dishwasher SOURCE AND TYPE OF WATER SUPPLY: well spring stream or creek Give depth of all wells within 180 feet of system:49 If supplied by community water, give name or supplier: 806 Scq.e,e00J 4'r e / ,NL - * - GROUND CONDITIONS: Depth to bedrock: Depth to first Ground Water Table: Percent ground slope: DISTANCE TO NEAREST COMMUNITY SEWER SYSTEM: Was an effort made to connect to community system? TYPE OF INDIVIDUAL SEWAGE DISPOSAL SYSTEM PROPOSED: C) Septic Tank Aeration Plant Vault Vault Privy Composting Toilet Recycling, potable use Pit Privy Incineration Toilet Recycling, other use Chemical Toilet Other - Describe: FINAL DISPOSAL BY: t .,) Absorption Trench, Bed or Pit Evapotranspiration Underground Dispersal Sand Filter Above Ground Dispersal Wastewater Pond Other - Describe: WILL EFFLUENT BE DISCHARGED DIRECTLY INTO WATERS OF THE STATE? 10 J Page 2 SOIL PERCOLATION TEST RESULTS: To be completed by Registered Professional Engineer.) Minutes per inch in hole No. 1 MinutesAr per inch in hole No. 3 Minutes per inch in hole No. 2 Minutes per inch in hole No. Name, address and telephone of RPE who made soil absorption tests: Name, address and telephone of RPE responsible for design of the system: Applicant acknowledges that the completeness of the application is conditional upon suchfurthermandatoryandadditionaltestsandreportsasmayberequiredbythelocalhealthdepartmenttobemadeandfurnishedbytheapplicantorbythelocalhealthdepartmentfor purposes of the evaluation of the application; and the issuance of the permit iS subject tosuchtermsandconditionsasdeemednecessarytoinsurecompliancewithrulesandregulationsadoptedunderArticle10, Title 25, C.R.S. 1973, as amended. The undersigned hereby certifiesthatallstatementsmade, information and reports submitted herewith and required to besubmittedbytheapplicantareorwillberepresentedtobetrueandcorrecttothebest of my knowledge and belief and are designed to be relied on by the local department of healthinevaluatingthesameforpurposesofissuingthepermitappliedforherein. I further under- stand that any falsification or misrepresentation may result in the denial of the application or revocation of any permit granted based upon said application and in legal action for per-jury as provided by law. Date Signed 0010 PLEASE DRAW AND ACCURATE MAPTO YOUR PROPERTY 5-c 977 Page 3 PLOT PLAN AND DESIGN FEATURES: Include by measured distance location of wells, springs, potable water supplylines, cisterns, buildings, property lines, subsoil drains, lake, water course,stream, dry gulch and show location of proposed system by direction and distancefromdwellingorotherfixedreferenceobject, and additional submissions in support of this application such as data, plans, specifications, statements andcommitments. JET 17T4C//4 5 - 44 /54.77 - Page 4 1319 CR 127 Legend 1319 Co Rd 127 100 ft N ➤➤ N NORTH 1/4 CORNER SECTION 28 SITE BENCH MARK FOUND REBAR & 1-1/4" YELLOW PLASTIC CAP LS19598 ELEVATION:6200.22 OWNER SAMUEL R. FEUERBORN & LINDSAY JO. GURLEY PARCEL NO. 218578200024 RECEPTION NO. 909988 1319 COUNTY ROAD 127 GLENWOOD SPRINGS 10"/28' 7"/12' 6"/12' 6"/12' 6"/12' 8"/32' 7"/20' 7"/20'8"/16'6"/12' 12"/24' 7"/16' 6"/12' 6"/20' 7"/16' 7"/12' 7"/16' 6"/12' 6"/12' 8"/28' E INV6266.64 INV 6268.04 INV6270.02 INV6262.25 27.0' 8.0'8.0 ' 52. 3 ' 52. 3 ' FFE : 6 2 8 6 . 5 0 27.0' PA V E R S DECK STE P S RE T A I N I N G WAL L SHED ONE - ST O R Y FRAME H O U S E 1319 CO U N T Y ROAD 12 7 GRAVEL PARKIN G AREA GRAVEL DRIVEW A Y GRAVELROADWAY MO U N T A I N S P R I N G S ROA D 24 " C M P 2 4 " C M P MOUNTAIN SPRINGS ROAD 50' WIDE EASEMENT RECEPTION NO. 264393 PRO P E R T Y L I N E 50' WIDE RIGHT-OF-WAY EASEMENTRECEPTION NO. 264393 25' F R O N T SET B A C K THREE MILE ROAD 10"/28' 7"/12' 6"/12' 6"/12' 6"/12' 8"/32' 7"/20' 7"/20' 8"/16'6"/12' 12"/24' 7"/16' 6"/12' 6"/20' 7"/16' 7"/12' 7"/16' 6"/12' 6"/12' 8"/28' E INV 6266.64 INV 6268.04 INV 6270.02 INV 6262.25 27.0' 8.0' 8. 0 ' 52 . 3 ' 52 . 3 ' FF E : 6 2 8 6 . 5 0 27.0' PA V E R S DECK ST E P S RE T A I N I N G WA L L SHED ONE - S T O R Y FRAM E H O U S E 1319 C O U N T Y ROAD 1 2 7 GRAVE L PARKI N G AREA GRAVE L DRIVE W A Y GRAVEL ROADWAY MO U N T A I N S P R I N G S RO A D 24 " C M P 2 4 " C M P 6305 630 0 6295 629 0 6285 62 8 0 62 7 5 62 7 0 62 6 5 62 6 0 6 2 5 5 6270 627 5 627 5 627 1 6 2 8 0 6 2 8 5 6 2 9 0 62 8 0 62 8 5 62 8 8 6253 62 8 3 628 4 PR O P E R T Y L I N E 50' WIDE RIGHT-OF-WAY EASEMENT RECEPTION NO. 264393 2 5 ' F R O N T SE T B A C K SURVEYOR 'S STATEMENT I, RODNEY P. KISER, DO HEREBY STATE THAT THIS EXISTING CONDITIONS & TOPOGRAPHIC SURVEY WAS PREPARED BY TRUE NORTH COLORADO, LLC. FOR SAMUEL FEUERBORN & LINDSAY JO GURLEY, THAT SAID SURVEY WAS PREPARED BY ME OR UNDER MY SUPERVISION AND RESPONSIBLE CHARGE AND THAT IT IS TRUE AND CORRECT TO THE BEST OF MY BELIEF AND KNOWLEDGE. POWER POLE DECIDUOUS TREE GAS SERVICE OVERHEAD ELECTRIC LINE SEPTIC LID LEGEND NOTES: 4.THIS PROPERTY IS SUBJECT TO RESERVATIONS, RESTRICTIONS, COVENANTS AND EASEMENTS OF RECORD OR IN PLACE. 5.THIS SURVEY WAS PREPARED WITHOUT THE BENEFIT OF A TITLE COMMITMENT, THEREFORE, ANY EXCEPTIONS TO TITLE THAT MAY AFFECT THE SUBJECT PROPERTY HAVE NOT BEEN REVIEWED BY TRUE NORTH COLORADO, LLC. 6.ELEVATIONS SHOWN HEREON ARE BASED ON GPS OBSERVATIONS UTILIZING THE CONTINUOUS OPERATING REFERENCE STATIONS (CORS) THROUGH THE MESA COUNTY RTVRN NETWORK BROAD CASTING NORTH AMERICAN VERTICAL DATUM (NAVD88) YIELDING AN ON-SITE BENCHMARK ELEVATION OF 6200.22. 7.CONTOUR INTERVAL EQUALS ONE FOOT. A PARCEL OF LAND SITUATED IN THE NW1/4 AND W1/2NE1/4 SECTION 28 TOWNSHIP 6 SOUTH, RANGE 89 WEST OF THE 6TH PM COUNTY OF GARFIELD, STATE OF COLORADO EXISTING CONDITIONS & TOPOGRAPHIC SURVEY TRUE NORTH COLORADO LLC. A LAND SURVEYING AND MAPPING COMPANY P.O. BOX 614 - 386 MAIN STREET UNIT 3 NEW CASTLE, COLORADO 81647 (970) 984-0474 www.truenorthcolorado.com PROJECT NO: 2020-436 DATE:December 21, 2020 DRAWN RPK SURVEYED GBL SHEET 1 OF 1 TRUENORTH A LAND SURVEYING AND MAPPING COMPANY 15'7.5'30' SCALE: 1" = 15' N 0 NOTICE: ACCORDING TO COLORADO LAW YOU MUST COMMENCE ANY LEGAL ACTION BASED UPON ANY DEFECT IN THIS SURVEY WITHIN THREE YEARS AFTER YOU FIRST DISCOVER SUCH DEFECT. IN NO EVENT MAY ANY ACTION BASED UPON ANY DEFECT IN THIS SURVEY BE COMMENCED MORE THAN TEN YEARS FROM THE DATE OF CERTIFICATION SHOWN HEREON. PROPANE TANK 150'75'300' SCALE: 1" = 150' N 0 SE E D E T A I L CONIFEROUS TREE 6"/12'TREE DIAMETER & DRIP LINE SIZE ZONING Gareld County, CO Developed by Account Number   R080771 Parcel Number   218528200024 Acres 35 Land SqFt 0 Tax Area 008 2019 Mill Levy 73.2960 Physical Address   1319 127 COUNTY RD   GLENWOOD SPRINGS 81601 Owner Address   FEUERBORN, SAMUEL R & GURLEY, LINDSAY JO 1319 COUNTY ROAD 127 GLENWOOD SPRINGS CO 81601 2019 Total Actual Value   $455,190 Last 2 Sales Date  Price   7/31/2018  $255,200   9/19/2014  $117,500   Date created: 6/5/2024 Last Data Uploaded: 6/5/2024 2:09:53 PM 921 ft Overview Legend Parcels Roads Parcel/Account Numbers Owner Name Lakes & Rivers County Boundary Line