Loading...
HomeMy WebLinkAboutConditions of Permitco NDITIONS OF PERMIT BLRE-09-24-8892 BEN & THERESA WAGENMAN 1,723 SO FT Secondary Dwelling Unit (SDU) over an 2,904 SO FT Conditioned Garage TBD CR 214, New Castle Maves Sub Exemption, Lot2 - 218106200283 1) ALL WORK SHALL COMPLY WITH THE 2015 INTERNATIONAL RESIDENTIAL CODE (I.R.C.)AND 2018 I NTERNATIONAL ENERGY CONSERVATION CODE (I.E.C.C.) 2) PROPOSED IMPROVEMENTS ARE SUBJECT TO ALL APPLICABLE ITEMS CONTAINED IN THE ATTACHED "GARFIELD COUNTY BUILDING REOUIREMENTS". NUMBER REFERENCES NOTED ON PLANS REFER TO SPECIFIC ITEMS ON THIS LIST. 3) ELECTRTCAL pERMtTTtNG AND tNSpECT|ONS BY COLORADO STATE ELECTRIC BOARD. ELECTRICAL ROUGH-IN APPROVAL IS REOUIRED AT FRAME INSPECTION. ELECTRICAL FINAL APPROVAL IS REOUIRED FOR FINAL INSPECTION & CERTIFICATE OF OCCUPANCY. 4) ALL EXTERIOR LIGHTING TO BE DOWNCAST AND SHIELDED. 5) WILDFIRE MITIGATION RECOMMENDATIONS: SHALL COMPLY WITH WILDFIRE MITIGATION AND DEFENSIBLE SPACE RECOMMENDATIONS PER COLORADO STATE FOREST SERVICE AND LOCAL FIRE DISTRICT. PLEASE REFER TO THE GARFIELD COUNry COMMUNIry DEVELOPMENT WEBSITE FOR ADDITIONAL I N FORMATION. 6) OPEN HOLE SOTLS REPORT tS REOUTRED AT FOOTING INSPECTION AND PRIOR TO ANY CONCRETE POUR. PROVIDE COPY OF GEOTECHNICAL ENGINEERS REPORT TO THE BUILDING INSPECTOR. 2,000 PSF soil bearing. 7) SEPTIC SYSTEM REVIEW / APPROVALS: PRIOR TO FINAL BUILDING INSPECTION & CERTIFICATE OF OCCUPANCY PROVIDE FINAL APPROV /SIGN-OFF FROM GARFIELD COUNry'S PUBLIC HEALTH DEPT. 8) AN ELEVATION SURVEY, SEALED BY A COLORADO PROFESSIONAL LICENSED SURVEYOR, IS REOUIRED AT FRAME INSPECTION TO VERIFY THAT AS-BUILT ROOFS COMPLY WITH GARFIELD COUNTY'S 25-FT BUILDING HEIGHT LIMIT AS DEFINED IN THE LAND USE DEVELOPMENT CODE. 9) SECONDARY DWELLTNG UNtT (SDU) rS GRANTED LAND USE APPROVAL THROUGH GAPA-1 -24-8994. OWNER BUILDER MUST ADHERE TO ALL CONDITIONS OF PERMIT STAPLED TO THIS FIELD COPY, INCLUDING DIRECTOR'S DECISION LETTER DATED JUNE 24, 2024,XCEL ENERGY WILL SERVE LETTER DATED JULY 1 0,2024; AND KUMAR & ASSOCIATES ROCKFALL HAZARD REVIEW LETTER DATED AUGUST 27 ,2024, 1O) SUBJECT PROPERry OFF OF SLAUGHTER GULCH RD SHALL RECEIVE FINAL APPROVAL OF THE DRIVEWAY ACCESS BY THE FIRE MARSHAL PRIOR TO SCHEDULED GARFIELD COUNry BUILDING FINAL i C.O. FINAL INSPECTIONS. SEE ORRIN MOON LETTER DATED OCTOBER 1 ,2024. 1 1 ) BLOWER DOOR TEST tS REOU|RED. MUST SUBMTT BLOWER DOOR TEST REPORT TO GARFIELD COUNTY COMMUNITY DEVELOPMENT DEPT. OFFICE PRIOR TO SCHEDULING FINAL BUILDING INSPECTION / C.O. FINAL. 12) PRESCR|pTtVE PATH W|TH 2018 tECC TABLE R402.1.2 lS CHOSEN FOR ENERGY COMPLIANCE OF THE HOME. ALL NEW HOMES TO HAVE WHOLE.HOUSE MECHANICALVENTILATION SYSTEM INSTALLED (2015 IRC TABLE m1507.3.3(1)AND (2)AS STAMPED ON SHEET A-101) \e \) qJ ri s\ cj).\ \ ss