HomeMy WebLinkAboutWelding Final Inspection ReportMONUMENT STEEL INSPECTION, LLC
Conklin Welding Fabrication, Inc.
Glenwood Springs, CO 81601
ATTN: Mr. Eric Conklin
RE: Hutten Residence
1003 Cattle Creek Ridge Rd.
Carbondale, CO
*Field Inspection
Dear Mr. Conklin,
5-15-2024
As requested, bolting special inspection was conducted per the IBC 2018
Edition -Chapter 17: Structural Tests and Special Inspection and Garfield County
requirements. I arrived on-site at 10:45 AM. I met with you to review the material to be
inspected and project requirements.
High strength bolt inspection was conducted at this new residence according to
the on-site plans supplied by TK Engineering Consultants, LLC. I observed all bolts on
the ground, pt , and 2nd floors. I observed all bolts to be¾" ASTM A325 Plain Body
bolts fitted with hardened flat washer properly positioned under the turning surface of a
heavy hex bolt. Those bolts that were not sheared off due to issues such as clearance
were checked for tightness with a wrench. Upon completion, I observed all bolts to be in
compliance with project specifications and the inspection criteria of the American
Institute of Steel Construction (AISC) and the Research Council on Structural
Connections (RCSC).
Monument Steel Inspection, LLC
PO Box 23388
Glade Park, CO 81523
318.469.2279
monumentsteelinspectionllc22@gmail.com
Respectfully submitted,
Dan Bricker, CWI
AWS CWI #09052051W
Monument Steel Inspection
Monument Steel Inspection, LLC
PO Box 23388
Glade Park, CO 81523
318.469.2279
monumentsteelinspectionllc22@gmail.com