HomeMy WebLinkAboutRescheck Energy ReportGenerated by RE5check-Web Software
Com pl ia nce Certificate
Project NS5103 Wagstrom
Designer/Contractor;
Northstar Systembuilt
?l,VlNtS6 CSNSiJLTIl'|fi .
db*$AtlC$ fi
Thitd Party Flan RtrBivw X
AsprtvalF*r S
trl ,tx6.d-r*aaict f?13/3*e4 I
g.4.il-JESJd
12
80
80 87
\.'
(tEnergy Code:
Location:
Construction Type:
Project Type:
Conditioned Floor Area
Glazing Area
Climate Zone:
Permit Date:
Permlt Number:
All Electric
ls Renewable
Has Charger
Has Battery:
Has Heat Pump:
2018 IECC
Silt, Colorado
Single-family
New Construction
L,972 tt2
L7o/o
5 (6881 HDD)
false
false
false
false
false
Construction Site
Ceiling: Flat Ceiling or Scissor Truss
Ceiling L: Cathedral Ceiling
Wall: Wood Frame, 16" o.c,
Door: Solid Door {under 50olo glazing}
Door 3.: Glass Door (over 50olo glazing)
Window: Vinyl Frame
Basement Wall: lnsulated Concrete Forms
Wall height: 9.0'
1,71r
26t
L,746
37
4A
257
0.026
0.026
0.060
0.300
0.300
o.300
44
7
85
1L
12
77
Owner/Agent:
Kopper Creek
Compliance: 4.30/6 Better Than Code Maximum UA: 323 Your UA: 3og
The % getter or Worse Than Code lndex reflects how close to compliance the house is based on code trade-off rules,
It DOES NOT provlde an estimate of energy use or cost relative to a minimum-code home.
Slab-on-grade tradeofls are no longer considered in the UA or perfcrmance compliance path in REScheck. Each slab-on-grade
assembly in the specified climate zone must meet th€ minimum energy code insulation R-value a*d depth requirements.
Envelope Assemblies
{
l_\
s\
-\
\s
50.0
49.0
2L.0
0.0
0.0
0.0
o.026
o.o22
0.057
0.L95
0.300
o.3l-o
44
6
80
7
15.0 0.046 0.050
Cornplia*ce: Passes usi*g UA trade-cff
Cavity
R-Value
Cont.
R-Value
Prop, Req,
U-Factor U-Factsr
Req
UA
Gross Area
Perimeter
Prop,orAssembly UA
L,746
lnsulation depth: 9.0'
Project Title: N55L03 Wagstrom
Data filename:
Report date: 06105l24
Page 1 of 2
Compllance Statement: The proposed building design described here is consistent with the building plans, specifications,_and other
calculations submitted with the permit application. The proposed buildlng has been designed to meet the 2018 IECC requirements in
REscheck Version : REScheck-Web and to comply with the mandatory requirements listed in the REScheck lnspection Checklist.
Amanda Johanneck, QC Administrator Q*Z"rrrrr*06t1812024
Name - Title Signature /NAfA
TWti$1$6 f Slj$lJtTl Nfi
"
dbs t4Al3CO
l}krJ Party Flar Reui*w
AfF{{rval F&t
bv 'tf****!i)**;t9.
ry3#024
&An1#526
o
{t
c
#
A.
{
Project Title: NS5103 Wagstrom
Data filename:
Report date: 06105124
Page2of 2
2&18 IECC Energy
Efficic n6y Ge rtifi cate
d
d
TW'l'{!196 CSI$$lJtTit':S.
ribsSABCO il
Thkr:l Prrty Flan Reviw I
Ay*rsvalFar *
bv ,$aS*ti!)*uiet f
ryV?s?i$ *
xAD-18626
Above-Grade Wall
Below-€rade Wall
Floor
Ceiling / Roof
Ductwork (u nconditioned spaces) :
Window
Door
21.OO
15.OO
o.oo
50.oo
o.31
o.30
95 AFUE
12.2 EER, 14 SEER
Heating System: Gas Furnace
Cooling Syste m: SEER 14.0
Water Heater: AT|240H Gas Tankless Water Heater.g5 gp
Name: Amanda Johanneck Date: A6nBl2O24
Comments
R-\ral$elnsulation Rating
€,lees & Dosr Rating U-f actor SHGC
lleating & Ccoling Eguipme*t Effic,iency
CALC LATI
. NEC N{}RTH$TA3
Building Type 2 Box-Custom Home - NS5103
Air Conditioning (100%) "Area Watts or Volt-Amps
Central Electric Space Heating 0 x 0.G5*0
Less than 4 separately controlled
electric space heating units 0 x 0.65 0
Four or more separately controlled
electric space heatinq units 0 x 0.40 0
* Use the larger of the air'conditioning load or
the diversified demand of the heatinq load.
Other loads:Area Watts Circuit Wire size
General lightins (1st floorl 1980 x3 5940 204 12-2WtG
General lighting (2nd floor)0 x3 0 204 12-2WtG
General lightinq (Bsmt)0 x3 0 204 12-2WtG
Smallappliances 7 x 1500 10500 2gA 12-2WlG
Dryer 5000 304 10-3 WIG
Water Heater-Gas ati-240H 2404 204 12-2WlG
Cooktop-Gas 1800 204 12-2WtG
WallOven 10400 40A 8.3 w/G
Dishwasher 1200 204 12-2WtG
Garbaqe disposal 700 204 12-2WtG
FanlLiqht {2@150)300 204 12-2WtG
Furnace - Gas 1000 20A 12-2WlG
Washer 1500 204 12-2WIG
0
SUB.TOTAL 4A740
First 10 KW of other loads @ 100o/o 10000
Remainder of other loads @ .40%30740 x .40 12296
Heat {Above}0
TOTAL CALCULATED LOAD 22296
Required Service size 22296 240 =92.90 amps
lnstalled Panel size 200 Amp Panel
{
G
T\.!:l N tNS tC'ilsutr1 l{fi ,
dba BA{::(:{} nu
Thir* Plny Flrrr R*vieH >
aplrrrval F*r S
bv .d.s$cf3J*rr*4 f7/B/z*ze t
xAD-t8626