Loading...
HomeMy WebLinkAboutInsulation Certificate¨Energy Saver FP™ Insulation System Designed for metal buildings, the Energy Saver FP insulation and fallprotectionsystemprovidesanef¿cientstate-of-the-artway toinsulateandcreateleadingedgefallprotectioncompliantwith OSHAstandardswheninstalledbycerti¿edinstallers.Thisproduct hasbeentestedandcomplieswith: •ASTMC665,TypeI•ASTMC167•FlameSpread<25 •ASTME84 •ASTMC991•SmokeDeveloped<50 •ASTMC553 Single Layer Roof System ¡R-309½”¡R-258”¡R-196” Double Layer Roof Systems (New construction) ¡R-43(R-30+R-13)13½”¡R-36(R-25+R-11)11½” ¡R-40(R-30+R-10)12½”¡R-35(R-25+R-10)11” ¡R-38(R-28+R-10)11”¡R-33(R-25+R-8)105/8” ¡R-38(R-25+R-13)11"¡R-32(R-19+R13)10” ¡R-38(R-30+R-8)11"¡R-30(R-19+R-11)9½" Triple Layer Roof Systems (New construction) ¡R-49(R-19+R-19+R-11)15½” ¡R-48(R-19+R-19+R-10)15½” ¡R-46(R-19+R-19+R-8)14½” Single Layer Wall Systems Double Layer Wall Systems ¡R-43(R-30+R-13)13½” ¡R-288”¡R-41(R-28+R-13)12” ¡R-30(R-19+R-11)9½” ¡R-309½”¡R-258” ¡R-196” Designed for metal buildings, the Purlin Glide FP insulation and fallpreventionsystemprovidesanef¿cientstate-of-the-artway toinsulateandcreateleadingedgefallpreventioncompliantwith OSHAstandardswheninstalledbycerti¿edinstallers.Thisproduct hasbeentestedandcomplieswith: •ASTMC665,TypeI•ASTMC991•FlameSpread<25 •ASTME84 •ASTMC553•SmokeDeveloped<50 •ASTMC167 Single Layer Systems ¡R-309½”¡R-206”¡R-134”¡R-103” ¡R-258”¡R-196”¡R-113½”¡R-82⅝" Double Layer Systems ¡R-32(R-19+R-13)10”¡R-26(R-13+R-13)8” ¡R-30(R-19+R-11)9½”¡R-23(R-13+R-10)7” ¡R-29(R-19+R-10)9”¡R-20(R-10+R-10)6” ¨Unfaced Metal Building Insulation Anunfaced¿berglassblanketdesignedtobeusedasaback¿ll materialinavarietyofinsulationsystems.Thisproducthasbeen testedandcomplieswith: •ASTMC665 •ASTMC991•FlameSpread<25 •ASTME84 •SmokeDeveloped<50 ¡R-309½"¡R-216¾"¡R-134"¡R-103" ¡R-288"¡R-206"¡R-123½"¡R-82⅝" ¡R-258"¡R-196"¡R-113½" ¨Faced Metal Building Insulation Afaced¿berglassblanketusedinmetalbuildings.Itisusually installedbetweenstructuralsteelandsheeting.Thisproductdelivers guaranteedrecoveredR-valuepriortoinstallation.Thisproducthas beentestedandcomplieswith: •ASTMC665 •ASTME84 •FlameSpread<25 •ASTMC991 •SmokeDeveloped<50 ¡R-309½"¡R-216¾"¡R-165"¡R-113½" ¡R-288"¡R-206"¡R-134"¡R-103" ¡R-258"¡R-196"¡R-123½"¡R-82⅝" ¡2”Condensation Blanket Fiberglass Insulation Facts Fiberglass insulation is made from mineral substances processed frommoltenstatetoanincombustible¿brousform. Facing Facts •Standardresidentialbuildinginsulationfacingswillburnand shouldnotbeleftexposed. •Residentialinsulationvaporretarderfacingsshouldalways beinstalledtowardthewarm-in-wintersideofthedwelling. •Vaporretardersmusthavearatingof1permorless. •Special consideration should be given to facing choices formetalbuildinginsulationproductsinareasthatwillbe exposed to excessive amounts of UV light such as buildings withopenwalls,largedoorsthatwillbeopenfrequentlyorto buildingsthatwillutilizeindirectlighting. Sound Facts •FiberglassinsulationincreasestheSoundTransmission Class(STC)ratingwhenproperlyinstalledinbuilding assemblies.Ithasbeendeterminedthatthicknesshas greatervalueinsoundcontrolthandensity. •NRC(NoiseReductionCoef¿cient)dataisavailableformost commonly-usedproducts. silvercote.com Metal Building Insulation Submittal Date Submitter Project Submitted to OTHER:___________________________________________ ¨PurlinGlideFP®InsulationSystem 10/21/2024 Scott Nathan THC/Jammaron/28210366CR Sentinel Bldg Systems ©2017Silvercote,LLCSIL165-0108/17 R-value R-valuemeanstheresistancetoheatÀow.ThehighertheR-value thegreatertheinsulatingpower. Flame Spread, Combustion and Federal Testing •SilvercoteLamination'sunfacedmetalbuildinginsulationand facedmetalbuildinginsulationhaveaclass“A”ratingofÀame spreadof25orlessandsmokedevelopedof50orlessin accordancewithASTME84testmethod. •SilvercoteLaminationmetalbuildinginsulationhasbeen testedandhaspassedtherequirementsofASTME136 combustioncharacteristicsandisconsiderednon-combustible bymajorbuildingcodes. Recycled Glass Content SilvercoteLamination¿berglassinsulationproductscontain43% postconsumerrecycledglassand6%postindustrialrecycledglass. Fiberglass and Mold Fiberglassinsulationwillnotsustainmoldgrowth.However, moldcangrowonalmostanymaterialwhenitbecomeswetand contaminated.Carefullyinspectanyinsulationthathasbeen exposedtowater.Ifitshowsanysignofmolditmustbediscarded.If thematerialiswetbutshowsnoevidenceofmold,itshouldbedried rapidlyandthroughly.Ifitshowssignsoffacingdegredationfrom wetting,itshouldbereplaced. ASTM C665 Requirements Include The Following Test Methods: •ASTMC518andC653-ThermalResistance(R-value) •ASTME84-SurfaceBurning •ASTME970-CriticalRadiantFlux •ASTME96-WaterVaporPermeance •ASTMC1304-OdorEmissionSECT13.8-Corrosiveness •ASTMC1338-FungiResistance •ASTMC1104-WaterVaporSorption Unfaced Insulation Markings: R-valueisprintedonthefaceoftheproduct. Underwriters Laboratories: Batts/BlanketsULListingBZJZ.R9602;BKNV.R9602Restive Design. AdditionalCerti¿cations: (maynotapplytoallproducts,checkindividualproductliteraturefor details) •CityofNewYork,DepartmentofBuildingsCodeCompliance forunfaced¿berglassthermalinsulationcodesections27-232 and27-348non-combustibility.NYCMEA417-91-Mforloose- ¿llinsulation,andMEA416-91-Mforbatts. •StateofCaliforniaBureauofElectronic&ApplianceRepair, HomeFurnishingsandThermalInsulationcerti¿edproduct listinglicense#TA1275. •ComplieswithCASection01350.(ULGreenguardGold productscomply) •CompliancewithCityofLosAngeles,Californiarequirements forthermalinsulations. •MinnesotaInsulationStandardsProgram. •NationalStandardofCanadaCAN/ULC-S702-09for preformedandloose-¿llinsulations. •NationalResearchCouncilCanadaCCMCEvaluationlistings forbattsandloose-¿ll. Not all Silvercote products areGREENGUARDCerti¿ed. See applicable product speci¿cationsfordetails,or visitUL.COM/GGtoviewour certi¿edproducts. Please contact your Silvercote Sales Representative for more information at (844) 232-3701 or info@silvercote.com