Loading...
HomeMy WebLinkAboutPlansMooel:21M1052-V1 Customen OFFICE Builder: KOPPER CREEK BUILDING, LLC. Manufacturer: Commodore Homes of lndiana Commodore Homes, LLC 1902 Ceniury Drive Goshen, lN 46528 Adopted Codes: State of Colorado The lniernational Residential Code, 2018 Edilion The lnternational Mechanical Code. 2018 Edition The lniernational Plumbng frde,2018 Edition The lnternational Fuel Gas Code,2018 Edition The Naiional Elecirical Code,2020 Edition lniernational Energy Cursenation Code, 2018 Edition I CCR 1302-14 Administrative Rutes - CDOH Project Location: 18786 HWY 50 MONTROSE, CO 81403 MONTROSE County Occupancy: Occupancy: ..................lRC - Single Family Dwelling Conshuction Type: .......58 (lAiood Frame - Unprotected) Number of Stories:.......0ne Story Cape Design Load: Floor Area: ....,......................1 980 Sq.Ft. Ground Snow Load: .............52 psf Roof Live Load: ................."..40.0 psf Top Chord Dead Load: ........10 psf Wind Speeds: VuLr = 130 mph Maximum Elevation above Sea Level: ....N/A ft lnsulation Reference RESCheck lor Requiremenb. Floor Live Load: .......................40 psf Floor Dead Load; ..........._.........10 psf Bottom Chord Live Load:..........30 osf Wind Exposure Category: ........C Seismic Design Category: .......C IECC Geographical Code: .......N/A THEATTIC CAN BE USED AS HABITABLE SPACE. ALL SITE WORK MUST MEET EGRFSS REOUIREMENTS. ALL SITE WORK WILL BE DONE ONSITE BY OTHERS. IF THE ATIIC IS USED AS HABITABLE SPACE IT MUST BE REVIEWED, INSPECTED, AND APPROVED BY THE LOCALAHJ. State of Coloracio Dlvision of Housing Aprl22022 PLANS Subject to field inspection Attention Local lnspection Departments: 1 . Set-up instruclions for the modular unit are included in the home. 2. Ile following items are not completed by the home manufacturer, are not inspected by in-factory thirdparty inspectors, and are not certified by he modular compliance label: (A) compon*e o, .onnJui*, for heating or air conditioning systems which arc NOT part of the factory installation. 1ay aeiow noor duc{s. (C) Electrical service disoonnecl {D) Foundation designs and attachrnents. ln orOerio ueriry matall required systerns mnnections are complete, refer to ttre "lnspection check sheef in tnemanufucture/s moduiar home instailation manual. Regardless of factory or site installation, the fumace, water heater. and all elernents of heating system must be per applicaLb codes, (refer to ResCheck if applicable). 3. site installed fumace must meet |ECC Energy Efficienry certificate if applicable. 4- !3_{i?l plumbing installalion (sttlbbed in) requires full Dwv testing in fietd. Testing of factory portion of _ ?WV i. noi required unless parlial testing is mandated by mde. 5' Smoke deiectors required by code that are not shown o; the plan will be site installed by others and are subject to inspection by he authority having jurisdiclion. g JJ Drawing lndex Tifle Page Cover lcu Floor Plan FP Proposed Cape Floor Plan PCFP Electrical Plan EP Schedules and General Notes NG Elevations EL Cross Section lxs Hot Water Lines l*n Cold Water Lines WC DW System DL DWV Notes lo* Supply Air Ducts - Perimeter Registers SP Ceiling Return Air System HR Braced Walls-Prescriptive lnwe Foundation 2x10 Maniage Line without Stair FD4O# Floor Framing FF Floor Framing Details A-10-10 Roof Framing RF Siair Details lso Dormer Details ATTACHED 8rr//,Q fr/e zLM1h Note: Window fall proteciion must be provided on-sile where required in accordance wiih applicable code. 68 -0. 43-5'54'-51? | 2t^9 1tr Jt--:- JL*k -.11-- (3)2x6 Edse (B1G1f-1j ,, 41i7-.11--- (3)2x10 E@ (Bt0is1) ,, 1112' -l----i H- (3)2x6 Edss {8101007280 LIGHT: 12.6 SF8% VENT: 6.3 SF4o/" THEATTIC CAN BE USED AS HABITABLE SPACF. ALL SITE WORK MUST MEET EGRESS RFAUIREMENTS. ALL SITE WORK WLL BE DONE ONSITE BY OTHERS. IF THE ATTIC IS USED AS HABITABLE SPACE IT MUST BE REVIEWED. INSPECTED, AND AFPROVED BY THE LOCALAHJ. lOieai State of Colorado Division cf l-lousing Aprl22AE L/R AREA: 281.0SF LIGHI 22.5 SF 8% VENI: 11.2SF4% 3882 3050 (3)2xO Edse($1[1]ll 3050 3050 {3)}6 Edse (3)2x6 Edoe{}101Fit (B-1c-iGtt 7240 (3)2x10 Edse 1grts1or) q. dt(3)}10 Edoa {81&1&l)- 13'{' ,3'{', to-0" -l Bhmd I- (3)2xo Edqe (FlF1C1,{3)46 Ede'iil1o1}ii TffiryJER |_4 1#6l1f I , ,, 4'r--t- -i 1'.7112 4'-81t ,r-i l-l r 41t2',, 4112"-'1'-PLANS15'{" Subject to field iuspection8S 15',S [6{" r -l Notes: 1. Exterior opening headers and jack studs are SpF #2 unless olherwise noted. i. liflewall headers may use alternate construction per section B-10 ofsystems Manual. 3. LVL's where specified to be minimum oi 1 i/2,,wide, M.O-E. = 2.0 and-lb= 2900 pSl. n _'il!- B/R-3 AREA;120.4SF LIGHT: 9.6 SF 870 VENI 4,8 SF4% Office AREA:144.9SF LIGHT: 11.6 SF8% VEN': 5.8 SF4% 12 cm Nook AREA: UGHI:11.3 SF8% VENT: 5-6 SF4% i-Btlt 30 Am:ss 30 M-B/R AREA; 205.1 SF UGHT:16.4SF8yo VENI: 8,2SF4% Floor Plan 21M1052-V1 PCFP&i tlc liniled hl leidsliiq @nnediof,s tofo$n&don. sitercfis. Sibsoi(Fustbededg*dSYO1}jERSktrsite@rdilbns, undeitc€l j!ilsdiclioi. COMPLIAI|CE tllTHAfLAPPLICABTE CoDES pER LOC,{AuIt{ORuy HAVING JURISDICTION, \I,IIETHER DETAILED IN THls SEIOR I.IOI MUST frclbrt6,$dl podiors ol the podj.ns bliit @ sitect L insbilgd elecrlssib Note: Window fall protection must be provided onsite where required in accordance with applicable code. SECOND fLM IAYOUI,ITLUDNG MECHANIC.4L AND :LECGTJL TO SE OESIGNEDAND CO\S'MUMD Sffi BY OIH:RS, AlI SM WOAK HCY BE SUBJ:C'TO FFIX NSPECiIS\S AilD ilUsI MNFORM IO Atr STATE trD LOCAL C00ES. State of Colorado Division of Housing Aprl22/2(t22 AU SIIOG DEITCTORS TO UVE BATIERY BACK.UPst To 8E INRCON|{ECIEC y,tfi A 14 g Mtr INTERC'ilNECISI WNE CR F&TJALENT ER IIFG RECOIME\DANq\S ft Subject to 6e1d insirection CHA$ DORMER I!] WINDOW X L-__- Pepopd Sesnd F@r All d68n mlerials a1c rc* to be the respoisblrycl the brildeis on sih lo leal cod$. Ught. venl egre6s. he?lirg aid plumtng are the Espdsitilty ofle bdj.s. Area: 853sq. ft. THE ATTIC CAN BE USED AS HABITABLE SPACE. ALL SITEWORK MUST MEET EGRESS REQUIREMENTS. ALL SITE WORK WLL BE DONE ONSITE BY OTHERS. IF THE ATTIC IS USED AS HABITABLE SPACE IT MUST BE REVIFWED, INSPECTED, AND APPROVED BY THE LOCAL AHJ. Notes: 1. Exterior opening headers and jack siuds are SpF #2 unless olherwise noted. 2. Sidewall headers may use alternate construction per section 8.10 ofsystems Manual. 3. LVL's where specified to be minimum of 1 1/2" wide, M.O.E. = 2.0 andfr= 2900 pSl. € 5o 2LM1 flrcNS 8OX CCTN:C IEO TO A 3AF ffiUIV$B 1ffi NAELS FOR FIILO NSfr LIED &NEAli!ffi SEE G GFI/WPR 38 State of Colorado Division of Housing Aprl22l2O22 q--r *J FCR S GFIA/VPR Subject to field inspection JUNCTION BOX FOR PREWIRE FOR SMOKE DETECTOR WILL BE PROVIDED F '9 Ii( -w 8 I Nook 5 PE@ , g,l 6 Electrical Pian ;=1---il- sM l,sd{ 21M1052-V1 .s 1.44 1,44 'l,92 10_56 1-44 't.92 't.92 1.5i1 NM'](}ZWG NM12-2TWG NMl42fWG NMl{-?i1'G NM14.2/wG NM12-'MG NM1+2MG NM142rwc NM1,{-2,I\/l/G NM14-2 VG NM142MG NMt&2 fiG NM12.2MG NM142MG 1 1 1 1 1 2 1 4 4 2 2 t5 15 20 ii0 40n 20 15 20 20 ([cnedNooKlsull 6an tAtuyuFuil 8ab 1r Pantry{AFcll Heciric BB Heal Ltsposat(fru) Taokl€ss WH Beciric vliitl Eec,lric Fum€ uunory TffiRomrmil- Mffir sedmm lAFcu Chdc^.m.ltur lAFaI rdc uvnq K@F lryll) ffiof Re€pts lAFct/GFl Strlal Amfre {AFCUGF( Hesnc urys{uFcf Elecrtric Ranffi IGFCI) El€ctic Codftp Etecfic Wall OYef, Gas t umae {AFCI) Becbic Fume !.EffifAFCI] usnwasnef tAfLl,GF Ltcrcwave Uwn {AFCI) Garage (AfguGFCt) I 1n t3 t h1a 1 ? 3 4 5 7 I 20 25 40 4! 43 4 SHGC wlo Grids (f +;uc+rtue*trt Design Load 45 45 45 o Yes a a Egress False o 0.30 0.30 .X10lCiTF€ifi U Value 0.30 @=nrcesnueu; @ @ ?=iroollftr lll]ldratEs4Tr"\g,rlt';E\fi 6il8#f o;lb6H'*'." 6*t%H' @F'.Sf;iec* d ff=tNnfi$sl,ETu3$1yr.{il.l&f Endyj$ctDNTsjEt;o l-l +ilsttiors:U WTl,ilIH FI{ E:PIIELSX =AViA{i(l{f:IIET ttlcAllCll $vtfiii"rB,.:REEXiil6{.S!f,R=T]{nilSTAl I rs,10lGt0s,i1[ @r:=ncrcucinCsrclec0AtAM O =coAjiv SF Room 56.25 141.25 w 4SO0 sm Vent z-5L 5.77 I 2 as 2(x,&nps lnstalled Light 4.50 1 1.30 22.ffi 7 R/O SF 7.11 30_33 15.38 R/O Height 36.25 60.25 nea!n9 orAr&odrrodng 5,sleh !ro.&{c), Uk th. Nn. ddc d qt ta fi-tuFlcs l* sdFpl€me n6l el edn. h e.ir hE Gqur pscnt ror hear-p{np sFtehs _ rn.rude 6. hea!F!np 6mp€s5or3) at l@, t ahe ta.tNnp @Fessu i3 Ntwtcd fim rydiw wt&k *Flcm.ttaltcL turenddronrog rDd cootriEs'5r.d3,,nd Jd.ng ftcrt widrh R/O 28.25 36.75 72.5 50 Label ?430 Optional Method Load calculation for One-Family Dwellings Model f 1 cc.c6r L,gh:.ng fid Recco6d. brdr ZOelBl({3x 1980 {fi' !srrE ourstdo dln.nrlons) 1Sx 3I hli-&Frr.n@ 6iiqh cdrs r?O!l6t(21 iddded- 270.711c)ltl $mx 1i bundryEEich cRU,cGj 22qs?toli2l At t.ost a. I*ndry&aft, dt &, m$t & ntded u4 th2 tdned@ tug rf dt A/acqLi@entb$, se4i@. qplio.a llstea.d in Ft@ xlhMrtly4.edd {r) Ek.rnc H:O He:rer S wA N€dzdbasxr;F..'w;tl, tr)Etctu.D+r _-_-___llwatuw ote6, @kcq, ftot*, 11) €tcon. Ra4s ______lli rya adadhesdtFt' @nAtil? lo)ge.h. qa'&n6 o kva @h.dot.wti.gEtvotuFes lo) ttcdr. rBttun(D) o wA to$haFercsbyhdtiptrry {1) hhER} 1,5 KJA {2, ventF..5 os eA {rl Mirmsrk S wA hl Dr5hqarhc s wa I1l R!togedro s NA _--wA WA 3m4 Splran.e5 ?2032{s)11 and {r) lll rpp. USED t Apply:20.Si(S) denridt do.Ethc r.nt oa Inq !Seleb 4. €fio -1O,@= t2640 _ x,$%= 1156 +0,mo: ffi El.dcrpne.hcring.q!rFn.n! ii ioqrormorc sapcft lclyranioll(d uorrt: t .dncrpr.c-hertnZ.q!rFd..!'r tcsarrin torr tra nrf pl.1e h,q(. sFr.ss qdLl/iry tut ttb ,Et*tial Ecdi.1heft nt stoEge &oti.rhcatina!t:tads o t roi:lvollhpEe __ 600 + 23056 qcm.nd r..dj iLalnt+4raiiii6a-&t -- *;- 24Add. tu tdat dr zgofi REFER TO RESCHECK FOR DOOR AND WNDOW U.VALUES WINDOW SCHEDULE - MOD SINGLE HUNGARGON OR 2/0 CopF<r DENOTES EGRESSS SUFFIX DENOTES SAFETY GLAZING I E SUFFIX w to&odEE. 86[ShaRs oJe4?Frcrsh.tt@dyv/ tdbk lIO.t6. sizc ih. scM<a dr Fcedn. co.d!do6.,se jlorsits//r:l t ttu ke s.tue Mfg MI MI ID NO.LOAD AlvlPS POTES REO'D WRE SIZE roAD(ff) STAIRWAYS RISER HEIGHT 7 3/4 MAX TREAD DEPTH. 10" MIN. HEAD ROOII 8O"MIN. Sble of toloGdo Divisira oi tloBing AslnJm22 _h ELSCIRTS! PdlN?TS 8Smfl ffi 2I&1 ALLffiCtsSAIEilffiW' C@MRRECSIS ALLCLOgUGHXTOBEETIOSSSUR}CEIWXTNXTURES, Ir!iN.FMUSJMGSFACE ALL RSEPTS i l 8i Gmutflf6 np€ piR 2tGnEc sEcs, sltrNG. tilsTALL{tNS. FC. TO C$rfl"y tqft xgc RffimTs. SERVC€ PN;L hY 8E MfrED IildilG S!&j.d b ncld ;$rijon ALL SrcG AtrilS TO MVE SNRY MCK{P ND TO 6E INGRCSECT:D \'{TH A 1{ d T.1tr I$ItrCdNECiE{WS 1* SSLE S EtrU{ENI P:R MiGS RECMSMIUIS,trERIOR Ugl AT ESGE SDE NY 3; REPUCED, SSAVF PAilA 8OX lffiiilED {r. ALLExruRGECEFTctrsAREcireFERREsrgrmmusrenmwniouri6.li*n-iirlruuorlnar&Anc$srHloutFTffirBoxswlnErmnED^sqmofl. 12 cfi8|crfrTYPEAFoBRsKEnsiREtrourREDFeruravcrtcurispxcepii#iiliilrirCiirmmls.smcru'$rNrsH:DM-srfrrtrsAmcrfiffis 1r. ouETBgxEsmTmrxTHEcgurenusrsrmfrFleomnu:tNnceuNGrruiffi nnritsurm*.rd wHRLF&REcsrAcEsuusrFEGFo,TA$pERR€ssTiluma;mrrvrmEsisapnxeCiiiii ic AFsFrAcGoslETrsRruREDffiptrHs,B*corsmoecrswacrrngncigiseiFi-ffiinsnsaegrcsuaunerryfR:gRDEsssrH:sEGffipmcH,&LcwffiD:tr. BY ruCol$sgma. WHERERilui;oilL&ALc@€,AsaspRoEcTvEHtrsH[EEmtrDEDAmtsnLLEooNlEEyorERstNtcc*o$gyift?thEcsEcnflaa, lf an altach€d garage is to be added to ihis home, lhe enkance dmr to the hme fm lhe garage must be a sellclosing ire Eled door p€r app{icable coda Clolls dryer vents may n€d lo be compleled to lhe exledor of lhe hore oo site, Refer lo smliom of applimble lmal codes ard to Seclion I of lhe horde inslallalion manual ftr required mpletr'm of &yer venllalion as rpc€ssary. Schedules and Generd Notes 2LM1 I NOIi HOMES WTH ATTIC SPACE OUALIF/ING AS MATTSLE, MUST BE EOUPPED WTH EMERGENCY ESCAPE AND RESCUE OPENINGS REGARDLESS OF WHETHERAMC REA IS FINISHED M UNFINISH€D. CPENINAC MAY OCCUR ATENOW{L OF AMC ND/OR AT ROOF DORMERS IN ln&lAIilER ARRNGEMENT NECESSARY TO INST'RE ThT ANY SLEEPiNG ROOM MS AT HST SE ERESS OPENING. FRONTVIEW State of Cclorado DMsion of !-icusing Aprl22l2022 q-- ll.\ PT 4 NT( REAR VIEW Subjrct to ficld insocction 1t le SIDEWAU i{IGM lIIICIUOES R[IJOST AS DECKIreJ Elevations 1052-V1 6 7 3 4 D 7 I I 10 11 t2 IJ 14 15 to 17 18 1S 20 21 u 24 25 to )7 LSGEND JACK POSI PIER OR CONCRETE FILLED POST THAT MEFTS OR EXCEEDS REOUIRED SUPPORI CAPACITf PER FOUNDANON DESIGN. EXTERToR WALr INSULAT|0N {SEE |NSUTAT|0N R-VALUESi. 2X6#3 SPF EXIERIOR WAI STUDS. (SEE SIUD O.C. SPAC|NG NO]E) 2X6 #3 SPF SIDEWALL BOTTOM PLATE 7/16'MTED SHEATHING. VINYL 0R HARDBOARD STUNG (RANVERT.0R HORZ) |NSTALTED pER MFGR.'S INSTRUCTIONS. AIR INFILTRATION AND WATER RESISTANT BARRIER. 2X4 #3 SPF SINGLE OR DOUBLE TOP PLATE. 2X6 TREAIED SILL PLATE. FASIEI{NG OF SII AND HOME TO FOUNDATION ON SI]E PER CODES OR BY LOCAL ENGINEER WHEN APPLICABLE, 2X4#3 SPF INTERIOR WAU STUDS. {SEE SIUD O.C. SPACING NOTE} A4 #3 SPF BOTTOM PLATE IN]ERNR WAI.IS, TYP- ENGINEEREDTRUSSES SPACED IO MEET DESIGNED GROUND LOAD SIiOW LOAD, VAPOR BARRIER, CEILING BOARD 12" GYPSUM. 7/16'24/16 MTED ROOF DECKING MIN.IYP. 2X4 #3 SPF MIN. VERT. RAII. CONT. ON BO'IH SECTIONS OVER fulATE WALL. USE APPLICABLE SEAM ovER oPEN SPANS [ryp.) pER pGs c-1s10 0F sysTEM DOCUMENT. RIDCE VENT Typ. 5070 VEmnTIQN OF RoOF CAVry (UppER PORT|ON), TNSTALLED pER CoDE REQUIREMENTS. HI-PRO ARCHITECTUMLSHINGLES. INSTALLED PER MFGR'S INSTRUCTIONS- SHINGLE UNDERLAYMENT TYP. JOIST HANGERS AT MA]EUNE(S), 1'MIN. SPACE FOR ATI]C VEN11LATION. TYPICAL ICE BARRIER PERSECTION 905 OF APPLICABLE CODE" cErLtNG TNSULATTON Typ. ISEE TNSULATTON R-VALUESI 2932" (0.S.8.) BoARD DECKING. ALUM., VINYT OR |.|ARDIE SARD FCCIA AND DRIP EDGE. FLOOR CAMTY OR PERIMEIER WALL MUST BE TNSULATED ON SITE OR AT IltE FACT0RY {SEE INSU| ATION R-VAIUES) PERIMETER RIM JOIST MUST BE INSULATED TO R.VALUE LIS]ED FOR EXTERNR IYAIIS 28 INSULATION INSTALLED ONSITE BY OTHERS PER'IHERMAL REQUIREIIEI{IS AND/OR STATE AND LOCAL CODES 29 VEN]ED SOFHT 50% OF LOWER ROOF VENTIIATION. 30 BAFFLEREQUIRED 31 DRIFTBLOCKER 32 FLOOR DECKING RA'TED FOR 19.2" O.C, JOIST SPACING MAX. 33 MtN. 2X10 #,2 SpF FL00R J0IST 16'0,C. 34 2X6#3SPFDOUBLETOPPIATE. 35 WALL C0VER|NG (MtN. 1t2'cypsuil). THE ATTIC CAN BE USED AS HABITABLE SPACE. ALL SITE T^/ORK MUST MEET EGRESS REQUIREMENTS. ALL SITE WORK WILL BE DONE ONSITE BY OTHERS. IFTHE AITIC IS USED AS HABITABLE SPACE IT MUST BE REVIEWED, INSPECTED, AND APPROVED BY THE LOCAL AHJ, *nEnfi 942 Sjd€wall 1745 !pasngI lljss { G30C9F THF ATIIC CAN BE USED AS HABfTABLE SPACE, ALL SITE WORK MUST MEET EGRESS REOUIREMENTS. ALL SITE WORK WLL BE DONE ONSITE BY OTHERS. IF THE ATTIC IS USED AS HABTTABLE SPACE IT MUST BE REVIEWED, INSPECTED, AND APPROVED BYTHE LOCALAHJ. 1V SYSTEMS MANUAL REFERENCES FLoOR CONSTRUCTTON: A.1S.10 & END TO FACE OF TRUSS TOP CT1ORDS 0.131" NATLS (MtN. l.PENEIMnoil) N SID€WALL CoNSTRUCIION: &i0.10 CENTER WALL UPUFT DETAIL B-2O10 COLUMN REQUIREMENTS: &2G20. 21 & 30 INIERIOR WALIS: B-3G10 & 1 1 BEAMS: S10"10 IHRU C1&30 FASTEN COIIAR IIES EACH wlrH (14) srup o.c. sPActNG ETTERIOR WAIlj 1A II.ITERIORWAI.! 16' Sbb otCchedo Divaon oi hdr€ ApQmn 12 ei-- q t'loIEs: FOLLOW RECOMMENDED ATTACHMENTS FOR FASTENING OF HOME TO FOUNDATION. FOUNOATIONS TO BE BUILT AND CONSIRUCTED BY OI1IERS ON SITE. FOUNDATToNS {By Olfi ERS) MUST MEETALLAPPLICABLE CODES. NOTES AND/OR ILLUSIRAIIONS SHOWN ARE TYPICAL AND MAY NOT APPLY TO AIL HOMES CONSIRUCTED. CONSJRUCIION & SP€CIFICATIO.TS MAY VAfiY PER PTAN. REFER TO INSIALLATION MANUAL FOR MODULE CONNECIIONS. REFER TO INSTALTATION MANUAL AND TRUSS MFG. DIAGMM FOR ROOF IRUSS BRACING- 21 25 Sdjccr b lii)d ii+frbn REFERENCETHE APPROVED SYSTEMSPACKAGE FORADDITIONALAND SPECIFIC CROSS SECTION INFORMA]]ON INSULAIION R.VALUES CEILING:44 CElLlNc (Belwen Knee Walls: 30 EXIERIOR WALLS imntinm): 0 EXTERIoR WruS (@iV):21 FLOoR:0 FOUNDATION WALLS FOUNDATION WALLS (ctrlirues):10 (6ily):11 MATELINE OPENING 33 0 1 9.25'2PLY HOilE TqWFACilREDTS UIFINISffi CSD SISG-AMC IAYN G30C9F b?iN (4 #sx3.v w0OD ScREwS EACH SIDE OF TRUSS 3 Cross Seclion 21M1052-V1 WHFS: IL{TDING, TLC Mt11m\n 2tlt1052-V MAX VERI]CAL SPAC|NG (Fr.i 4'{r MNGER SPACING - PEXPIPE(SUPPLY) MAX HORIZONIAL SPACTNG (Fr.) tffi: i. 3g'GALVANIZED,mCSFERREUFDRAfr itoTSHOJ,Ni THRU AmRMuSttsGAFGAp?, tNLflWrHl'C P&Cl+}L 1.911.!!{1!s1s,!xFR:ssED,NpARENrHEsstA}B)tNDlcaTEIDFT.FRwRiAR€N0oFHsrEF(ooRrDsT.FEoltp.oilEr,qrEUIEJ.{. ANT}SCA'.D DEVIC€ ON ATL SHOI{R, ATD IIJBSHO*AR COTIBIMIIO|{S.5. UIATEF.HATIM'RARRESTORSATEITIERYOFFT$URESINSTALIED!,II}iEfrEV€RTHEREISAAUJCK.AO$NGVALVECONFOR}.IS]GTOASSElOlO& [iANUFACIUR:RS NSMUCIN5- SHUT-o.-F VAIVE tS REOURED AT 6ACH FXILF!i. gqTHRSIIS YIITA DOJBIE LAVS ARE FEO F8OI.{ IHi WE RSER.E. ANYUNEXOTLAEELEDFlUc WAERHaTERTESITERATUREIfRaSSIFEhELEFVALVEANDREUEFoMtNFtp€tNsrAltsmRFAfluFAcilR€R.ssp!ffims. JO. SruT-FFVALVEATWAIERHEAIESISFUTLFiXVil!'EIN5TALLEOONOLDWATERSlPptYNPEAT6qO]!'IA]EAH5ATE3,PERCODA 11. FULLWAYSUT-FiVAIVE't?lTllSLEEDORtBtEINSIA|-LEDATITAN|UEISERVICEvAt\E.INS,TALIEDON$rE,piACoC:. 1A SE!SYSIEI,ISPACNGFPLUMSINGSCTB\ ?AGESfuRODTIAW PLUIIBreNSESANBDEIIs SFE NMS FOR DIAGM'J EXPI"ANAIIOI,! A. WHENvEtTlcALBrruREr,{AtEisjpPtRFdRS0NLYAiEsHo,vNc'!iT},6prAN.firsERso\ryAREFAcTmyNsrALtEDAssHoimANDrEMntrrED BEltr/TFE FLffiATTHE IND#]!D Loall0l,ls. rBrEsAL PFot{sss,sreEii mumeNs,rEsIilG,ANo NspEcTlo\ FsALt Bnornm CONNCCTbilS Affi Oil SE BY OTI€RS IN ACCffiDANCE VTrft [I STAIE trO LMLCSES.8. WHENB€!O}TR@RwsIEMcffiEcTnNfoRIsERsAffisliof#&PsNBYw|loilN.s.IHESEAffiCoHPLEIED.EED.NONSP:CIEDTIITe F clcRy To IitE IEoitNAuaN poilT sltov{Sd{ IUSTRAIED Fhil.C. DOTIED-U-NiSSPUN,fRISNI.ARTNHO:DONLYTOITUSRTTWPfrIOXSECNNECTNN.THESEAMFffiILU5RNONO\1Y&\D& NOT PROVIND. INSTALLE!, ETED. G ilSFECTED BY THE FACIffi.D, ALLSEIOJFLMWATiRUXESMUSTg€SETD,NSTAI.LED.ANDIESGDANSNEFERffiIICIMLOCALANDSTAIECOOES- SINK(8-s xtlar a-107/8 SHOWEH ffn'x 150 3/4rt6"$ 3I€ SHOWEH (O-Y x 146)s',€ 7/8'86 FROM MARRIAGE EDGEIAV (f-0'x 94) 4'-3'3tt 3t4 LAV (5?6 x 7/) BAB stNK BAR S|NK * g.gl424 x32l FUruRE TUB/SHOWEB (50'-$ x ttO 17tt 7tt 3l4x{-2 3tt t-27t8 4',-4 TI4 FROM MARBIAGE EDGE IVASHEB (36-0 vr x 9D cnpE pnEP {37-f x 156) 3/4x3€ 7/8'3/A a4 314x6-g 1l+ 3t4rt2-10 3/q vq 314x9'4112 Siaie of Colorado Division of Housing Aprl22f2A22 3/4x3-3 3/8' 3t4 ALL DIMENSIONS FROM REAR AND MARRIAGE EDGE 6 2-8 LAV (?-{} x 52) LINE SIZEO FOR DISIIWASHER 11\ PLANS Subject to field iospection Hot Water Lines B1t1 SPACING (Fr.) Ii,I,AX VER''ICAL 4{r HANGER SPACING - PEX PIPE (SUPPL\') MAX HORIZONIAL SPAC|NG (Fr.) {oBr. &'HLVAIIZEO,m WPER REUF DHN iIOTSioi\)rdRU amR,rMS€LEAtR qp2. INL-| HIH t cAP I CroYI DIIENSIOISEXpRESSEDIIIPARENTHESS(dx6]INDTAIE(DISI.FF$iReARENDoFHG{EFTmRTDISLFRO[4riottElrAlELNB.{. A{TISCALD DEUCI G ALL SHO'IR. AII) IIts/SOTIJ;R €VSMIOTS.5. VJATE+HAMM:R*RRESTOISATBIIENYO'FUIURESINSTAITED9JHEREVERTHER€ISAQUICK-CISNGVALVECO\FO$T!{GTOASSE10188 IIANUFACruR;RS NSMUCruS.6. SHUI-G'FVALVEIS REOUREDATEAft FHN.NE7. BATHROOIIStnlHmuBf uvstrEFEoFe6l ilESA#EF,E:R.8. A{Y tNE mT $ffir€o ls 1/I9. V'AT*HHTERETPIAITRE{RESSIRERELEFVATVEANDREUSORAINPIPEI.ISTALLEOPERSANUFACIURERSSPECfISI.IO.\S- ]8. SHUT4:FVNNEAT{IAIEqH'ATERISFULLOPiilVALVEIN3TAILEDONCOLDIJAIERSIJPPLYPIP;ATFACHWATERHE4IER,F€RCOC1 I1- FIJILWAYSH:JT.OFFVALVEU{NSLEIDO8lIt5({STATLEDAII',{T{INLETSERVICEVATVE,INSTATEDOI.I.!IG,PERCOOF- 12. SEESYSIEtrISPACNG€ PLUMSINGSECIMPAG:SFORMDIOMLFTIIAErcEANODAIdLS StrE NOT€S FOR DiAGRAI.I EXPUXA]IOII A. qjENERIgAL RXnJR€VIAGRSJPPYR[gtR3ONTYAAESH€i,?NOfi]tsphN.F,s€RsgN[AREFACTORYNSTALTEDASST{Ol,'ilANOTERjIilAIED aElor THE FLm AT THE IxDsftD tocATbNs. MrERrAt FRot4src{s,sysrEft coNiliEidils, TEsnNG, AND nspElol sm u uLir+ndiiCGINifrIONS ARE M $]: 8Y OI}ERS I$ ACCORDNCE VJMi [L STATE AXD !@41 COOES-I WHENSELolaRooRsYsTEllccNlEcllo$rToRtsERsARFSfl&lNoNplANsysouDuEs.rusEAREcsJpLETED,ESED,ANDNseclED}lftE FACIORY TO THE IERMT{ATION POtrT SHCI1II S ILLUSIRAT€D PUN c.9g]]ED_UIE!qI|UN,{FPfiESEI'lI},AffNIENDEoONTYTOILUSTRATEilprc[O$S]ECfrNECnoNS.THISEAtrFORUUSTRATNOTTYAND ARE NOI M]!18D, INSTAtrED. BTED, M NSFECITO BY BE FAfrffiY.D. ALLSA(,JROffiWATERTNESYUSTEESIIED,INSTATLED.ANsIESTEDq{S|TEFERAPPIEATLELOCALANDSTAEC@ES OPT. CEMAKEB (28'-8i x f/2) LAV (sf-5'x I4 t-27t9 RJNJRE IUB/SHOWER 314x4-2 5tff BAR PFEP (50-5'x 110 uz4 73){Sl-f x 156) SINK (23€ x 17D) 44 \t7-1O1lt BAR $INK St4x6\ 7-{5t4'1rc Qi$., s3Fa 1x4 1ts' tx4tlo 5l8F 6',-{)1lF Sl4x7 518447t9 INLET x0)f-3 STooL 60{ x 180) tcg-3 6il'-81 x 1B+) SHOIVER f/-f x 1511 sl4 STOOL (s-? x fl6) 1x1/J4 5.t8' HOSE BIBB (5'-r x State of Colorado Division of Housing 4pil2212022 SHOWER (g-9 x 146)7ta' 86 FBOM MARRIAGE EDGE 1I4 FROM MAFRI,AGE EDGE7-9 t LAV e4) 5/8'3f-5 3/irgt4Kt4 stq 3t{ 67t8f z-8 tAV (f-0 x 52) ft.{ 5-5 5/€r Subject to field inspection HOSE BIBB (f-f x 180)ALL DIMENSIONS FROM REAR AND MARRIAGE EDGE Cold Water Lines 21M1052-V1 DLP$ EUI[-DING. tLC VERTICALSPACING Vedical pjping shall be sup@ded at eah story f frffi level. HANGER SPACING. DMJN PIPE{DWV) MAXHORIZONTAL SPAC|NG (Fr.) A',.g NOTE: 1, AII UNES 1.I4 SLOPEIFOOT IdINIMUM UNI..ESS OIHERI,{ISE NOIED.2. <+ DENOIESI/8'S|OPEiFOoL 3. ALL?DIA LINES SHOWNFILLED FOLD)4. ALL LINES 1.1/U DIA. MINMUM O]HERWFENOTED,5. UNES SERVING STOOL ARE 3" DIA,CONfTINUOUS TO OUTITT.6. AIR ADMITTANCE VALVES SHOWII ARE IN ACCORDANCE dASSE 1051 & MANUFAC]URERS INSTRUfi IONS.7. VENT STACKS t\,lAY BE REQUIRED TO TRAIIS|T|ON TO gDtA BEFORE EXIENDING ]HRU ROOF IO EXTERIOR. REFER TO INSIALLATION MANUAL FOR ]RANSITION LOCAIION ANO INSULATIOilI REQUIREMENIS.8. CONTINUOUS WASTE APPL ON SINKS AND IAVATORIES W}IERE SPACING DOES NOTEXCEED 3O.9, STACKS CTEANED IHROUGH REIIOVABLE FXIURE P-IRAPS. 10. ]HE DISCHARGE LINE FROM THEOISHWASHER SBqIT BE NOT LESS THAN 1I2 INCH NOMINAL SIZEAND SMLLEI]HER BELOOPED UPAND SECURELY FASTENED IO1HE UNDERSDE OF THE COUNTER OR BE CONNECTED TO A DECK{TOUNTED DISIIWASHERAIR GAP F|TNNG TIIAf IS LISTED, WR 6o-a x fil) SEE NOTE BAR SINK (41-g x 36) BAF SINK VTR *.f .'t tAv (sr.t x s$Y STY d c-oP-qwR ll(37-1'x168) | l4tq x IfsrYb F COP. lt lt v I I 36) (36'-0 x 103) SINK STY e4€;x ?0) des- F i c.oP VTR (37-t x 3 FURN I(42-11'x O9) FUTTJRE TIJB/SHOI\IER VENT (5t}{" x fi) WASHER ItS WYE \'VIHB i Isrool i@41t2 x6a) !&t i' N vTR (36'-0 1/f x(0-9 146) SEE NOTE 7 3 CAPE PBEP {37-t x 156)VENT (37-f x 168) SHOWEF STOOL (a-7 x 1C[)) State of Colorado Division of Housing Aprl22l2022 86) LAV t? STY x y) I IL-- fr Subject to field inspection ALL DIMENSIONS FROM REAR MARRIAGE 2LM1 V1 MAIN FULL OPEN SHUT-oFFVALVE TO VENT SYS]EiI SUPPORT: VERTICAL PIPING: SUPPORTS AI iC' O"C. [4AX, OR BETWEEN FLOCR TEVELS HORIZCATTAL PIPING: SUPPORTS AT 4'O.C. [4qX, ENDS OF EMNCHES,AND AT CHANGES IN ELFVAiIOti ANDIOR DIRECTION, TMPARMS: SUPPORT LOCATED AS CLOSE TOIRAPAS POSSIBLE WHEN IRAP TO VENT EXCEEDS 3. WTR. HTR. FULLOPEN SHUI-OFFS NOTE: Waier heaiers, which have a :bad{-ftrr' preEnte/'0r a 'check valve' lo€teC in the md wabr hlei lhe. aE 10 be equipped with an sFansion tankinstall€dbetu€n lhe back-iovJ prevenlEr (ot check valw) and ihe trater heaier in order to alieyiate lhemal qpansion. WATER INI.EI UNIONS OR FLEXIBLE COPPER CONNECTOR T&P RELIEF VALVETO coNFoRM TO ANS| 21.22 {2015) 11t2 DISCHARGE PIPE " = AIR GAP NO IESS THAN]WICE THE DlAli{ErER 0F THE DISCHARGE PtpE, BUT NOTMORE THAN 6'. FOR EMMPLE, FORA DISCMRGE PIPE OF V4' INSIDE DTAMFIER GAP THE AIR GAP MUST 8E NO LESS I}IAN 1 .12" FLOOR SYSIEM TO INDIRECTWASIE RECEPTOR OR TO IHE OUTDCORS (NOT REQUIRED Y/IIEN RELIEF VALVE DISCHARGES TO PAN. . = VYHERE toCAL CODE ALLOryS, RELIEF VALIT DISCHARGE PIPE MAY EMPry NTO DRAIN PAN DISPOSAL I 1/2 DBt WYEW c.0. 1 1/245El 11/245 EL 2x1 1/2 x1 1/2 SAN T OPIOI.]AL DISI.MASHER IAILPIECE OPTIONAL GARMGE DISPOSAL PTUMBING ILLINOIS MODELS ONLY . USE DFiAIL ABCVE FOR OPTIONAL GARBAGE DISPOSAL. 11l2 P-1RAP NOTE Water healeN, whidl have a 'back-iotr prevstei or a 'check valve' loHied in lie @ld waier hlet lhe, are i0 be equipped with an dpansien tark iNzlled b€iw*n ih€ back flow prevenier (or chrck wtue) and flie mts healer h order to alieviate Sefinal exparFbn. Staie of Ccisracis Divisicn cf i.:oLrs!ftg Apr!2212Q22 FI.ANS Subject ta fieid inspeation P.IRAP TO DRAIN SYSTEM DRAIN RUN IO OUTDOOR OR TO NDIRECT WASTE RECEPTOR PROIIDF FUEL GAS SHUI-OFF VAIVE (IVHERE APPLICABTE) AND ELTCTRNAI SHUT.OFF MEANS FOR IIIATER HEA'IER. 9r.\' ON.SITE BY OTHERSPER APPIICABLE CODE, NO]ES ALL EELOW FLOOR PLUMBIiiG BY OIHERS. ALL FtmNGS BELOr,ry BOTTG14 CA!\i eEsHlpp€D LOOSEALI EELOW FLOOR PLUMBING ILLUSTRATIO\S ARE RECOTIMENDAT'IONS ONLY ON.SI]ECOND|T]ONSAND,OR RESIRICT1ONS$AY REQUIRESOTIEI..IOOiHCATONSoPl GARMGE DlsPosAL To BE LocATED oN KlrcHEN slNK wAsTE ASSEMBLY. ALt vEr{is rHRU Roorro oeg,. ra" urN.ABo!,EaNdsilou/ no,lF FEr.EIRATlol,l.ALL P-IMPS TO BE I '1JZ'UNLESS NCIED. HORIZoNTAL!€NTSLoPE: 1/8"PER F0OT NORIZONIAL DRAIN SLOPE 1/1'F€R IOOT DR^II].IVASTE AND VE\T PLUi.'EING TO BE PVC PLASTIC OR EOUAI- AfPROVED FOR DlWAPPlICqTloIiS, DRAII] AtID DISCHARGE PIPES SERVING WATER HEATERS TO BE CPVCOROTHERCODEAIFROVED I1ATERIALANY TRANSIT]ONS TO TIATERIALS. OTI-iER'THAT.I THE SPECIFIED VATERIAI- MIJSI INCORPORATEAN APFRO\ED F|TTJNG FOR CONNECI1OTALL TUES\{ITH WHIRLPOOL '\{UST EEPROI'iOED \(ITH ACCESS TO MOTOR, ALL RUMEING TO MEETOR EXCEEOCURRENTADOPTED FIUIIBING COOES. BELOI! TOF PTATES TYP, WATER HEATER PAN DWV Notes E;t J*I 74'{H.D.O0.) 1 53'-4'tt.D-CO) . 23q'56'-8'63',4' T:I State of Colorado Division of Housing Aprl22J2022 CilYJJPACE INSTAD OSIIE 8V OltsERS. 60!0 s10P a-*J Subject to field inspectiori 4€'11',.4j 42'4 4412' (FURNACE)HVAC SCHEDULE TENGTH 57'4' 16'{ 7/8" DESCRIP]ION DUCT - 7.5X22.13 DUCT - 7.5X16.13 DUCT - 7.5X16.13 QTY 2 LABEL A B t- SEE ATTACHED HVAC CALCULATIONS 21M1052-V1 SP [c tl 2LM1 Ba1 (sroRAGE FO4 M.B/R (NON-STORAGE BCX) iNollsToRAGE BO8 (NON-STOFACE BOX) Nook B/R-2 State of Colorado Division of Housing AprlZ2l2B22Kir o.--,.j UR BIR.3 PLAI.{S ufl Subject to freld inspection 44'-3 ITHERYJq! PAN) Lisl 5 2 7 1 36', 5 6 2 l0 Stor"ge Bd {13,t13€, lgx6 Ceiliog Griile 16x3[ C€iling Gille 6' lmrlaled Fld Dld B lNrlaled Fls Dud 6 SbnHlar tr Slad Cdlar Thermal Pa 2LM1 6.32 r8.94 2 t REOUIRED PROVIDED t0.12 t4.79 T ELIr!F- f, D INT 2 to.12 10.25 ol( NC f--lrii-F,-- 30.00 OK 1rS twsPI FNII 8.71 1 TEOUIRED ]ROVIDED 13$ 1re.'124 1/{ State of Colorado Division 0f Housing Aprl22l2022 =-Lsls?l= ft PLAI.IS Subject to field inspcction = Esced t!?tr sut".i. I Rml Heit'd c Sidszll HekhlRoctFilciEx@suELsclhwbh ultimate \llrd Smd V trtMdlidUiit MAIN FOUNDATION TIE.DOWN MUST BE CONNECTEDON-SITE BY POINT LOAD LOCATTONS AS NOTED (By OTHERS) ALTERNATIVE TIE DOWN CONNECTION MFIHODS APPROVED BY A LOCAL ENGINEER MAY BE USED. REFER TO THF IRC FOR FOUNDATION TIE DOWN REQUIREMENTS FOR 130 MPH OR LESS WND ZONES 21M1052-V1 FD4O# OTHERS TO T}€ S$E CONOT'ICTIS THB SEISMIC DESIG}I AND ATTACHNG IHE H'"E LATERAL. LOI.IGIIUDIMI. SHEAR UFIST' ALONG WfTH RESISfAXCE . Ltc. D1111t2l'n 2tM1052-V sEs 4.3K t3K o.7K g6 1l-fr I 14ffi I 2EA cd It it ded 'lq1ffi I 25K 24fl4fi |atr Jq36:12 |lZU &4U14 |r5.tr ROOF SNOW LOAO 40 PSF coLuMits & FooTtNGs MUST BE RATEB TO MEET THE CENTER LINE LOADS LISTED FOR CONNECTION OF THE HOME TO FOUNDATION AT BMCING WALLS, REFER TO tsMCED WALL$CALCULATED- PAGE, IF APPLICABLE. WHEN THIS PAGE IS PRESENT, HORIZONTAL AND OVERTURNING (MCKING) LOADS AT BMCING WALL LOCATIONS ARE INDICATED FOR THESE FOUNDATION CONNECTIONS. THESE LOADS MAY BE RECALCULA1ED AND REDESIGNED PER LOCAL coDEs T0 CoNF0RM T0 stTE CONDIT]oNS AS REQU|RED. REFER TO CHAPIER 3 (3.9 TtE DOWN T0 FOUNDATI0N) OF THE'MODULAR HOME |NSTALLAT|oN MANUAT FoRADUT1oML INFORMATION. REFER TO APPLICABLE CODES FOR CONNECTION QF HOME TO FOUNDAT]ON WHEN 'BRACED WALLS-PRESCRIPTIVE" PAGE IS APPL}CABLE. lqp l@ds noted are bsed on albwable stEss design [S). Capacity of suppofr (eolumns, foo{ings, clq} mud uc€cd noEd Kip loadg SAF}:E{ ry F@TSS NOI MlDE) IN ISDS SigR, a-t:A={l&E +:i:s:Nisn: saLcr0sFiqEil:v stlsiDroi'jtd roiFrsa[:)ssfr:*oE$. Siaie of Coiorado Diirision of Housing Aprl2A2O22 qq dJ PLANS Subject to field inspeciion bump olC . aro oa TRUss FLsi t6Es-1. FilN:tllOl6YOUTtSAFFUCAFLErOrcTEDr4YffllrStEilICACINGAtDHMUUrjSiltggRl$Opi-S[ffEFSTOSSTiLUBTIMflfCAOTffinAfffiSS NFCMNCN. CONSULI LCCNL GFICKS AND TNE APPL&BG LffiL CODES FA OTH:R RESRE#S [i DMIqG. D&TMWM UXN r Sr rP* r rrN ,-x wDiloHEftslmssrc?r{INcLUDEAg{ALLoi$&EEnflc!.rEsEctpNFcR}olEsvlnrrcronrunLglcss.qnslanueiivruianirie-il- AlLql[NCg rA$S lNrO A@Uffi rH: ZIC OgS. UTethl INS'ALGD ON ACH MAihCE SAU FS &8ffi ffi TOCnEt srctw. F rctr Fs uN;-lxo.s'B oN iHE URMGE vnu ilA]E uE rouNDArDN wDrff E To gE saED Eoun! ro^cluAl thNuscMs flffir;tT4 eq miNu r siinL itiiinsAcru LFLo*frgrsTHESEDrkENstosrcor{LsJFcRnlyviRANcETMrrqroacuirNffite-,Ar6rc!wnreglrm_crcewrsoon-nn FIESENCCUNT€RED V}RIASLES.AWAilUSTTIENS NEE&ED'N iCUN*Tb!WDIHDUETOSffiViMIEESffiATHWffiEHIM3. FORDftIATICNS&OAOTTERFWNDAIftIESIoN!€CNSULTAI@&FRCFESSruWA&YOFLSLSOGMSiML 4 STLPUEF STiS\cTO6ETERtSTAUTfl[giSLANUO6ILCCATCSES.St[FASt€{reSSmffFIERmffiEyip)srEDAtDsffiila:i.sssE Yqifi flox: DirA tuTi FosArHizeEs.5. CoMRft Co$Pi€sslvE STAE[Gtr{Pt:impsl,SW].F. CEffiRUNEU\ESUFtOtTSelSFAqEAn:tasDo\(t:4,6sFtrNEi:HHS:+a1rs-,flArL i cuwspAcEvErilurcNFtnTnEounEDst:[Nsusiiwsrmrrotccuwuiicrirusireur:onvre$H:c(i@umEos).NrAumNsvtrc rN cswrspicE Mrls woulD ra{DATErilsuxTrs rB: FLtrR flsrsu psspso€ Eiwtrofrcro trFEF ro reiucerrE rtwiin: diiii3UlmrN:s. w85N REOIIRA. ONE VEM Sru EE FOyl'$VSffi 3 FFOF SCH dRSaa Fcu{rAncrcorSTRucnilANDTlelwNRECUlELlEliTSFCAHCV€STeTStNSIFHSFSLMeC{aSrhyW:AFFLCASLEpRasctrft:C?CSa9IIIEUN_S UGS t€ED O]ER'ilSE -1 ="1-a'a3?"ol*l_ _ F___E_ _ __€_ __E_ __ E__ _ E__ ___E __E_ _ i2.lK 13F( 6.{K tabK to.lx 6.{K el{ rabxru-| 15!1o | 3sl -!sc-l -!ry-] 441, lsj-] "." I UNITB UN|TAPERIMETERWAI FLF 18V4: itN. CMWLSPACE ACCESS- LOCATTG{ 8E OEIERMITIEO BY SITE AI\D GRADING 2LM1* lf-lt 1/4"JXX Add436' r i1r31"ElDck 1s4' Siate of Colorado Division cf Housing Aprl221282. ti1{ FLANS Subject to fieid impcctioo I Sladi4" Adllss ,431 114' I XX 45-134. ,n a!"o l\su.l4ll9N BELow FLooR D lNsuLATtoN FoR FLooR cAvrry oF MoDUtEs rs NoT FAcToRy pRovrDED. REFER TO RESCHECK FOR REQUIRED FLOOR CAVITY OR FOUNDATION INSULANON. IN ALL CASES, PERIMETER JOIST ISTO BEINSULATED T0 EQUIVALENT R'VALUE AS SPECIFIED FOR ABOVF GMoe wnlL Cnviw.'rtiiS-tttaunrs prRMrrER JOIST FAcEsuRROuNDlNG RECESSED ENTRIES AND PQROHES WHERE PERTMETER JotsTs FoRM THi BouNDARy BETWEEN THE ourstDEAND THE CRAWLSPACE OR BASEMENT AREA. CwlsFeAm L€dSs B@ds Roule llole Frsl n il- 6 I oI C)A-10-10 OfTG. 20t" r t80' e4'o-c.19:lO.C.16'O-C. 188"173" 155' 196'18t' , 162" m ALL T'ABTEJO TSPANS Jotstr h0 *2 SPF MO *2SY? &2 f2SPF MAYADD6- {DBL. RtOTOCft FIED SP'NS FOR ACTI.IAL FLOOFWIDTFI TITLE TYPISALgFF-FBAME FLOOR SYSTEM D(2 MIN LEDGER FASTENED TO PERIHETEH JOIST WTTH 1 Mry" GLUE AND O.tsl x g NAILS AT3"O.C. FASTEN FIRSI RIM .rc}lsi'To FLOOR JOST WTH {4) - 0.131 xf }{AlLS EACH.lf,lst SEE APPLICABLE DETAILS FOR DOUBLE RIM FASTENING ALTERNATE LEDGER DETAIL .fifrsTNoTcHwml 2)(2 IIIN LEDGER SUPFORT },AY FE USED INSIEAD OF .IOISTHANGERS d ECUAL=eru.plsT.'- {?tt$ 12SPR NoTES: 1) 2x10 oR 2(12 FLooR JOFr, PER TABLE BELoW, Wlgt3? STURDT FLOOR DEcXtt{c 2l @NNECT lf{.tER RtM Jolsf TO JotST UstNc {ls}tsga STAPLES OR (i) - .lsl x s" NAILS AT EfiERIOR WALL SIOE. OI{ UATE WALL SIDE NAIL CX.JANTITY MAY BE REDUCED TO (4) NAil.s SINCE HANGER {OR LEDGEB) tS tt*$rAtisD AS WELL. HANGEBS OR LEDGEB NOT REOUIFED AT trrERloR WALI_ LF.ILESS coNnNJOuS FOT,MATION WALL IS NOT PEESENT. 3) FASIE{ Fu.r Jot$T DEPTH BLOCT(ING AT FtmT Tlr'o .rcFT BAYS AT MtO FLoOR AREA OF EACH END OF FLOOR. {RECOMMENDED . MAY BE SITE INSTALIED WHENr54Ftq)s REQUIRED.} Pr,frv l.loTEs -,i. LAF d ,- SEEAPPLICIBLE OECKINGDETAIS .,* NOTEs Sinie ol Cablado Div:sicn cf Hc$ing Fprrz.Zjzl& TYP, SfAH$IELL SEEAPPLICABLE DETALS FOR MD(. SIAIR OPEMNG AT.ID ALT. @NFIGURATIOI$S SlLjc.r td ficld iffirSci RIM TO FLOOR.PIST FASTENING AT MATING $IDE RAIL (SEE ALT. I-EOGER DETAIL) JO| T HANG€R OR LEDGER REQUIFED ATMATING SIDE l.l REFER TO }.IOTE.2 FOR RIM JOIST TO JOIST FASTENEB 113 4 RIM TO FLOOR.IOIST FASTENING AT EXTERIOR SIDE RAIL i JOISTF|ANGERMUSTBESTTE. ll.ls[AttED W}IERE DfiERIOR RAIL IS NOTSUPPOHTED BY ; COhMMJOUS FOI.hIDATON WALL (sEE MArE S|DE DEIATLS) (usP) JN28E (OR ECtUtV.) Joisr HAT.TGERTo BE RATED AT470#MIN. FASTENTO PERIMETER HAIL $JTTH.1S' OR.I13 MILSTO EACHSIDE OF JOIST HAI{GER PEF CI.I,ART. NAILS TO BE OF STJFFICIE}TT LENGTH TO ACHIEI/E MlN. l-tr?r PEIGTHAflON lNIo PEF|MEfEB.til$r. USE (Z) NAILS JCIST HANGER TO F1.oOR .btST {1 EACH S|DE OF JO|SD. sroE (/) .'131'x 3' lt{AltS INNER FIM TO FL0OR JoLST AT ErIERIOR WALLSIDE {tilo HANGER FECIIJIRED}. SEE APruCABLE DETAILS FOR OUTER RIM FASTENNG {4} NAILS MtN. AT MA]E WALL S|DE (SEE }orE-z) *r&t 0b.t ALTEBNATE (RECOMMENDED) CORNER tAP 6 3 I{O. OF I,|AILS EACH SIDEOF JOIST IIAI{GERTO Ril' JONST SPATTNG 131 16'O,C. ?_--.. i'--.--. :^-^ ^---J .tl e r -r.i-j-.:-'. ri:C I ? vrl .',i: i-=',: -':lre r.t1'lyfiX 15€ li7 IXXX _M XXt sraiFl F 3-11" l)co( 11{1a lxxiK 64'{'F|AT II 5gr( ti r 2 x 10 Thls HaU tt i fftt 1t I 18'-$', II r t, II ilt lftt+ FASTEN FIRST LvL TO IRUSS $/01 0.131xr MLS FASTEN SECONO LVL INTO FIRST LVLWi{s)0.1s1x5'MILS TfTTTITTTTTf tt {{}++ i2) 9ZS LW tum Hd II ttI 1m B (USP) JN28E JOIST HANGER TO BE RA]ED AT 470* MIN. FASIEN TO BEAM WIIH.13,i OR.113 NAILS TO EACH SIDE OFJOISTMNGER, TRUSS BOTToM CI{ORD FASTENED W{q 0.1 31x5' MILS 0R {4) f8x1.25" SCREWS PER END PLUS {2)$$x3.s'WOoD SCREWS EACH SDE OF TRUSS State of Colcrado Division of Housing Aprl22l2O22 c--ttT.l $uhject to field inspectioa 21M1052-V1 RFil1 2LM1 SD 3OV -TRAN S_]RC_8 _ 6_(tJ) UP STAIR STRINGIR MAKE 2 (38" VIDE) 11 114 I 5718 o RIP MEMBERS TO63/4'&DECK W 3/4'DFCKING J_+l LI]F -TotNl \\Y '.\zo Header ln Kneewall '10'-6' sl 3l N Siaie of Colorado Division cf Housing Apr|2ZZA22 F-(9tfr 9creTLZ ; <- LtJ =()s6 N ===JI --_J :C FEfq s!l -l1 _t 1112',X11t2" ol I]-] to iield insptrtion 3/4'RISER 10',-8 1t2', OMII LEDGER IN STAIR 6 7/16 4 13i10 11 1t4 47 ?o ttttl!lt oPnoMLFl W\LL\ Iltttlttl TT ,t Ilt Itt I 3tax1n | ! | NOSING-f*-L M III I III I II 10 3/4 It rtt r {i A *l 2X 10WallFraming Drywall Finished Under Stairwell @ 19 5/8 129 BENCH 2X10 Stak Detail CHAPTER 5. ROOF SETUP 5.4.6 Alternate Ship Loose Full Dormer 5.4.6.1 lnstallation lnstructions 1. Mark centerline of dormer all the way up roof deck to peak of roof. Roof deck must be perpendicular to roof ridge line. (Chalk line may be used or some other highly visible marking). 2. Mark dormer outline on roof deck. Reference provided dormer drawing for overall length and width. NOTE: Overall dormer length is twice its depth. 3. Position gable support walls on roof deck, flush with exterior wall framing. Level gable support walls and place temporary bracing to hold them in place. Fasten fascia boards to gable support walls to roof framing members with # I X 3,5" wood screws @ 6" o.c. 4. Place fascia boards on top of gable support walls, flush with the outside edge. Fasten fascia boards to gable support walls with # 8 X 5" wood screws @ 8" o.c. 5. Fasten mounting braces to roof deck along dormer outlines. Mounting braces should meet together at the ends, Fasten to roof deck with # I X 3.5" wood screws 24" o.c. 6. Place rafters in order 16" o.c. and 4" o.c. at all edges. Rafters should butt up against fascia boards. 7. lnstalldecking as shown on provided dormerdrawing. Fasten decking to rafterswith 10d nails 6" o.c. atalledges. B. lnstall 90# felt paper at valley areas. lnstall 15# felt paper and shingles per ARMA guidelines or per manufacturer's instructions. .,:/' NOTE: Domorlsohippod loo6e ln 3 s6oiq6 (!11 State of Colorado Divislon of Htlusing Aptl2212022 Fldgq+ lxc nsller Srltccl tr) liDl{l inspcetiDo (dormr ro bo Bhiped wilh r@l dochjng applied 5.4.7 CricketKit 12112 Roof Pitch NOTE: To tie the bonus box into the roof of the main house you will need to build a cricket with the materials provided. The cricket is basically a large dormer. 1. Once the roofs have been raised you will install the ridge beam from the top of the bonus box to the main roof, making sure it is perfectly level. 2. After the ridge beam has been installed you can begin setting the pre-manufactured or site built trusses onto the roof; beginning with the smallest one. lnstall the first truss as far up the main roof as possible while keeping the truss level. Each truss comes in two pieces. lt may ICI Figure 44 - Ship Loose Full Dormer Bldge {4) lc) [onidkriiiuni] I TM ladr.llrro6nilled Figure 45 - Cricket Truss be easier for you to work with the smaller trusses if you connect them together prior to installation using a 2X as a gusset. 3. Set them on the roof at same spacing as adjoining roof trusses, and toe nail them into the existing roof's trusses using two 16d nail al24" o.c. or 16"0.c., depending on the truss spacing forthe main house. Also nailone 16d nail between each truss and into the decking. This puts the fastening schedule at 8" o.c. Be sure to keep the trusses level. 4. The top of the truss kit will fit up under the ridge beam. 5, The header on the trusses should be at the same height as the collar ties. 6. Once all the trusses have been installed between the main house and the bonus box you can begin sheathing the outside. 7. After all the sheathing is installed, the felt paper and shingles are installed as normal. Page 28