Loading...
HomeMy WebLinkAboutConditions of PermitCONDITIONS OF PERMIT BLMF-O9-24-8910 KENT & WENDI OLSON 1,602 SO FT MANUFACTURED HOME ON ENGINEERED FOUNDATION CRAWL SPACE (t NCLU DES MANU FACTU RER',S 965 SO FT',U NFINISHED ATTIC', ABOVE) 2607 CR 314, New Castle - Sec 12, Twns 06, R91 - 218112200295 MANUFACTURED HOUSESARE REGUIATED & INSPECTED BYCOLORADO DEPT. OF HOUSING (C.D.O.H.)ANDALL FACTORY-BUILT RESIDENTIAL STRUCTURES INSTALLED IN GARFIELD COUNTY MUST MEET C.D.O.H. GUIDELINES FOR MANUFACTURE AND INSTATI.ATION AT THE JOB sITE. (2018 IECC'BLOWER DOOR TESTING'ON PREMISES AFTER INSTALIATION SHALL NOT APPTY FOR MANUFACTURED HOME TYPE - A5 CURRENT ENERGY COMPLIANCE FOR STATE OF COLORADO ISTO BEVERIFIEDATTHE FACTORY) 1) 2) 2\ FOUNDATION CRAWL SPACE & EXTERIOR DOOR LANDING / STAIRS SHALL COMPLY WITH 2015 I.R.C., 201 8 I.E.C.C. AND MANUFACTURER'S INSTALLATION REQUIREMENTS. REFER TO PLAN ATTACHMENTS FOR GARFIELD COUNry'S BUILDING REOUIREMENTS AND MANUFACTURER'S I NSTALLATION REOU I REM ENTS. WILDFIRE MITIGATION RECOMMENDATIONS: SHOULD COMPLY WITH WILDFIRE MITIGATION AND DEFENSIBLE SPACE RECOMMENDATIONS COLORADO STATE FOREST SERVICE AND LOCAL FIRE DISTRICT. PLEASE REFER TO THE GARFIELD COUNTY COMMUNITY DEVELOPMENT WEBSITE FOR ADDITIONAL I N FORMATION. ALL PLUMBING AND GAS PIPING CONNECTIONS MUST BE PERFORMED BY A COLORADO LICENSED PLUMBER, AND ALL ELECTRICAL CONNECTIONS MUST BE PERFORMED BY A COLORADO LICENSED ELECTRICIAN. ELECTRICAL PERMITTING AND INSPECTIONS BY COLORADO STATE ELECTRIC BOARD. ELECTRICAL ROUGH-IN APPROVAL, IF ANY, WORK PROPOSED IN UNFINISHED ATTIC. ELECTRICAL FINAL APPROVAL REOUIRED FOR FINAL INSPECTION & CERT. OF OCCUPANCY. PRIOR TO FINAL BUILDING INSPECTION & CERTIFICATE OF OCCUPANCY, PROVIDE BUILDING INSPECTOR WITH FINAL APPROVAL / SIGN-OFF FROM GARFIELD COUNTY'S PUBLIC HEALTH DEPARTMENT FOR INSTALLATION OF THE ON-SITE WASTEWATER TREATMENT SYSTEM. PROPERry OWNER CORRESPONDENCE STAMPED OCTOBER 23,2024 CONFIRMS FACTORY BUILT UNFINISHED ATTIC WILL REMAIN UNFINISHED DURING C.O, FINAL INSPECTION. SEPARATE BUILDING PERMIT APPLICATION TO FINISH FUTURE HABITABLE ATTIC LIVING IS REOUIRED IN ACCORDANCE WITH BUILDING CODES & LAND USE REGULATIONS IN EFFECT AT TIN/E OF FUTURE WORK. (ATTIC HABITABLE LIVING USE ls speclfica/{v not INCLUDED UNDER THE CURRENT PERMITTED scoPE.) GARFIELD COUNTY BUILDING DEPT. INSPECTIONS TO INCLUDE THE FOLLOWING: FOOTINGS DESIGNED AT 1,500 PSF, VERIFY 36 INCH MINIMUM FROST DEPTH & UFERGROUND INSTALLED. OPEN HOLE SOILS REPORT REOUIRED AT FIRST FOOTING INSPECTION FOUNDATION SEPTIC SYSTEM CONN ECTiON PLUMBING/GAS SITE FRAMING, STAIRS, HANDRAILS PER STRUCTURAL ENGINEERS PLANS AND FIELD COPY. FINAL INSPECTION & CERTIFICATE OF OCCUPANCY* *NOTE: GARFIELD COUNTY REOUIRES C.D.O.H. INSTALLATION INSIGNIA TO BE AFFIXED PRIOR TO FINAL BUILDING INSPECTION & CERTIFICATE OF OCCUPANCY 4) s) 6) /) { e $sB) B. C D E. F.