HomeMy WebLinkAboutRes Check Energy ReportGenerated by REScheck-Web Software Com pl ia nce Certificate Project McDermott Residence 5322 COUNTY ROAD 243 Energy Code: Location: Construction Type: Project Type: Conditioned Floor Area: Glazing Area Climate Zone: Permit Date: Permit Number: All Electric ls Renewable Has Charger Has Battery: Has Heat Pump: 2018 IECC New Castle, Colorado Single-family New Construction 4,2L2 ftz 2oo/o 5 (7313 HDD) false false false false false Owner/Agent: Compliance: O,7yo Better Than Code Maximum UA: 542 Your UA: 538 The o/o Better or Worse Than Code lndex reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Slab-on-grade tradeoffs are no longer considered in the UA or performance compliance path in REScheck. Each slab-on-grade assembly in the specified climate zone must meet the minimum energy code insulation R-value and depth requirements. Envelope Assemblies Construction Site: 5322 COUNry ROAD 243 New Castle, CO 81,647 Upper Roof Ceiling: Flat Ceiling or Scissor Truss Ceiling LOWER: Flat Ceiling or Scissor Truss Ceiling LOWER FLOOR: Flat Ceiling or Scissor Truss Main Level Exterior North Wall: Wood Frame, 16" o.c. Door: Glass Door (over 50% glazing) Main Level North Windows: Vinyl Frame Main Level Exterior South Wall: Wood Frame, 16" o.c. Desig ner/Contractor: M Baca Studio M Engineers 2546 Moonridge Drive Grand Junction, CO 81505 9703668690 studiom.engineer@gmail.com ,* 5 S \ N L,t75 300 347 514 s3 r67 432 49.0 49.0 49.0 20.0 0.0 0.0 0.0 0.0 0.026 0.026 0.026 0.059 0.270 0.270 0.0s9 0.026 0.026 0.026 0.060 0.300 0.300 0.060 31 B 9 T7 t4 45 22 31 8 9 18 16 50 22 Compliance: Passes using UA trade-off Gross Area or Perimeter Cavity R'Value Cont. R-Value Prop. Req, U-Factor U-Factor Prop. UA Req. UAAssembly 20.0 0.0 Project Title: McDermott Residence 5322 COUNTY ROAD 243 Data filename: Reportdate: 091'1.6124 Page 1 of1L Cavity R-Value Cont. Prop. Req, Prop. R-Value U-Factor U-Factor UA Req. UA Gross Area Assembly or Perimeter Main Level Garage Man Door: Solid Door (under 50% glazing) Main Level Door: Glass Door (over 50% glazing) Main Level Exterior East Wall: Wood Frame, l-6" o.c. Main Level East Windows: Vinyl Frame Main Level Exterior West Wall: Wood Frame, 16" o.c. Main Level West Doors: Glass Door (over 50olo glazing) Main Level West Windows: Vinyl Frame Basement Level North Exterior Wall: Wood Frame, 16" o.c. Basement North Door: Glass Door (over 50% glazing) Basement North Windows: Vinyl Frame Basement Level West Exterior Wall: Wood Frame, L6" o.c. Basement West Windows: Vinyl Frame Basement Level East Exterior Wall: Wood Frame, 16" o.c. Upper Level North Wall: Wood Frame, 16" o.c. Upper Level North Windows: Vinyl Frame Upper Level West Ext. Wall: Wood Frame, 16" o.c. Upper Levei West Windows: Vinyl Frame Upper Level East Ext. Wall: Wood Frame, 16" o.c. Upper Level East Windows: Vinyl Frame Upper Level South Wall: Wood Frame, 16" o.c. Basement Level SOUTH Exterior Wall Copy: Wood Frame, 16" o.c. Basement East Windows: Vinyl Frame Floor: Slab-On-Grade (Unheated) lnsulation depth: 4.0' lnsulation position: Horizontal lnsulation East Basement Wall: Solid Concrete or Masonry Wall height: 9.5' Depth below grade: 9.0' lnsulation depth: 9.0' West Basement Wall: Solid Concrete or Masonry Wall height: 9.5' Depth below grade: 9.0' lnsulation depth: 9.0' South Basement Wall: Solid Concrete or Masonry Wall height: 9.5' Depth below grade: 9.5' lnsulation depth: 9.0' NORTH Basement Wall: Solid Concrete or Masonry Wall height: 3.5' Depth below grade: 3.0' Crawl Wall NORTH: Solid Concrete or Masonry Wall height: 7.0' Depth below grade: 5.0' lnsulation depth: 5.0' 2L 40 773 66 689 25 100 1,49 53 66 163 50 37 136 25 161 25 167 25 299 216 50 160 0.450 0.270 0.0s9 0.270 0.0s9 0.300 0.270 0.059 o.270 o.270 0.059 0.270 0.059 0.059 0.270 0.059 0.270 0.0s9 0.270 0.0s9 0.059 0.270 0.640 0,300 0.300 0.060 0.300 0.060 0,300 0.300 0.060 0.300 0.300 0.060 0.300 0.060 0.060 0.300 0,060 0.300 0.060 0.300 0.060 0.060 o.3oo 0.700 20.o 20.0 20.o 20.0 20.0 20.0 20.0 20.0 20.0 20.o 406 26.0 280 26.O 253 26.0 68 26.0 208 0.0 0.073 0.055 0.0 0.0 0.0 9 11 42 18 33 8 27 2 1,4 18 7 L4 2 7 7 8 7 I 7 18 10 t4 0 6 12 42 20 34 8 30 2 16 20 7 15 2 7 I I 8 9 8 18 10 L5 0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 10.0 0.0 0.0 0.0 0.0 0.041 0.050 1,7 20 0.041 0.050 11 14 0.039 0.050 0.065 0.050 L0 13 4 3 9 7r_5.0 Project Title: McDermott Residence 5322 COUNTY ROAD 243 Data filename: Report date: 09116124 Page 2 ofLL Gross Area or Perimeter Cavity R-Value Cont. R-Value Prop. Req. U-Factor U-Factor Req. UA Prop.Assembly UA Crawl Wall SOUTH: Solid Concrete or Masonry Wall height: 3.5' Depth below grade: 3.0' lnsulation depth: 3.0' Crawl Wall EAST: Solid Concrete or Masonry Wall height: 3.5' Depth below grade: 3.0' lnsulation depth: 3.0' Crawl Wall WEST: Solid Concrete or Masonry Wall height: 6.5' Depth below grade: 3.0' lnsulation depth: 3.0' Crawl Wall NORTH Copy: Solid Concrete or Masonry Wall height: 7.0' Depth below grade: 5.0' lnsulation depth: 5.0' 235 15.0 0.0. 0.070 0.055 1"40 15-0 0.0 0.274 0.055 208 15.0 0.0 0.073 0.055 76 15.0 0.0 0.070 0.055 4 L2 25 9 3 9 7 7 Compliance Statement: The proposed building design described here is consistent with the'building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2018 IECC requirements in REScheckVersion : REScheck-Web and to comply with the mandatory requirements listed in the REscheck lnspection Checklist. Name - Title Signature Date Project Title: McDermott Residence 5322 COUNTY ROAD 243 Data filename: Report date: 09116124 Page 3 of 11- ffi REScheck Software Version REScheck-Web lnspection Checkl st Energy Code: 2018 IECC Requirements: 0.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Additiona I Comments/Assumptions: 103.1, 103.2 lPR1l13 Construction drawings and docu mentation demonstrate energy code compliance for the building envelope. Thermal envelope represented on construction documents. Does Not Not Observable Not Applicable !Complies 103.1, 103.2, 403.7 lPR3l1c Construction drawings and documentation demonstrate energy code compliance for lighting and mechanical systems. Systems serving multiple dwelling units must demonstrate compliance with the IECC Commercial Provisions. plies Applicable Does Not Not Observable Heating and cooling equipment is sized per ACCA Manual S based on loads calculated per ACCA Manual J or other methods approved by the code official. Heati ng: Btu/hr_ Cooling: Btu/hr_ Heating: Btu/hr_ Cooling: Btu/hr nDoes Not nNot Observable ENot Applicable plies 1 hlm (Tier 1)Medium I (Tier 2)Low I er Project Title: McDermott Residence 5322 COUNTY ROAD 243 Data filename: Report date: 09116124 Page 4 of1l 402.L.2 lFoLlls inComplies inoo"s not iIlrtot observable iflNot Applicable Slab edge insulation R-value R-R-See the Envelope Assemblies table for values.n Unheated E Heated n Unheated n Heated 402.t.2 lFo3ll 3 ilcornplies iEooes Not iEtrtot observable j[ruot npplicable ft ft See the Envelope Assemblies table for values. Slab edge insulation depth/length. Conditioned basement wall insulation R-value. Where interior insulation is used, verification may need to occur during lnsulation lnspection. Not required in warm-humid locations in Climate Zone 3. See the Envelope Assemblies table for values. R-R- R-R- ENot Applicable Observable plies Not 402.L.L lF04l1 3 303.2 lFo5l1 n Conditioned basement wall insulation installed per manufacturer's instructions !Complies nDoes Not ENot Observable !ruot Applicable 402.2.9 lFo6lr 3 Conditioned basement wall insulation depth of burial or distance from top of wall. EComplies EDoes Not ENot observable !Not Applicable See ihe Envelope Assemblies table for values. ft ft 402.2.'1,1, lFo7l1s R- R- R- R- Unvented crawl space wall insulation R-value. iflNot Observable lEtrtot Rpplicable nComplies nobes Not See the Envelope Assemblies table for values. 303.2 lFo8l1 o Unvented crawl space wall insulation installed per manufacturer's instructions. tes bleNot Do.es Not Not Observable 402.2.11 lF09ll a Unvented crawl space continuous vapor retarder installed over exposed earth, joints overlapped by 6 in. and sealed, extending at least 6 in. up and attached to the wall. plies Not Observable Applicable 402.2.1,r lFo10l1 3 Unvented prawl space wall insulation depth of burial or distance from top of wall. tn.lSee the Envelope Assemblies table for values. tn.plies Not Observable Applicable protective covering is installed protect exposed exterior insulation and extends a minimum of 6 in. below grade. nDoes Not nNot Observable nruot licable plies Snow- and ice-melting system controls installed.nDoes Not INot Observable lNot Applicable mplies Add itional Comments/Assum ptions: 1 hlmH ct 1)Medium lm act (Tier 2 Low lmpact (Tier 3) Project Title: McDermott Residence 5322 COUNTY ROAD 243 Data filename: Report date: 091L6124 Page 5 ofLL 402.1.'t, 402.3.4 lFR1l1a iEcomplies inooes ruot iEtrtot observable iENot Applicable Door U-factor U-U-see the Envelope Assemblies table for values. 402.t.1, 402.3.!, 402.3.3, 402.5 lFRzltg Glazing U-factor (area-weighted i U-_average). i I I I I I I Complies Does Not Not Observable Not Applicable See fhe Envelope Assemblies table for values. U- 303.1.3 lFR4l1 s U-factors of fenestration products are determined in accordance with the NFRC test procedure or taken from the default table. EComplies EDbes Not ENot Observable ENot Applicable 402.4.1.t lFR23l1 c Air barrier and thermal barrier i nstalled per manufacturer's i nstructions. nComplies nDo.es Not ENot observable flruot applicable 402.4.3 lFR20l1 e lFenestration that is not site built iis listed and labeled as meeting j nnun ruoun rcsA Lotil.s.2t A[40 or has infiltration rates per NFRC 400 that do not exceed code limits. plies Not Observable Applicable lC-rated recessed lighting fixtures sealed at housing/interior finish and labeled to indicate <2.0 cfm leakage at 75 Pa.nruot licable ENot Observable Supply and return ducts in attics insulated >= R-8 where duct is >= 3 inches in diameter and >= R-6 where < 3 inches. Supply and return ducts in other portions of the building insulated >= R-6 for diameter >= 3 inches and R-4.2 for < 3 inches in diameter. 403.3.1 lFRr.2l1 e nComplies nDoes Not ENot observable INot Applicable 403.3.2 lFRr.3l1 3 lDucts, air handlers and filter iboxes are sealed with joints/seams compliant with lnternational Mechanical Code or lnternational Residential Code, as ble.a nComplies lDoes Not ENot Observable Not Applicable Building cavities are not used as ducts or plenums.Does Not Not Observable tes bleNot 1 (Tier 1)Medium lmpact (Tier 2)(Tier 3)Low Project Title: McDermott Residence 5322 COUNTY ROAD 243 Data filename: Report date: 09lL6l24 Page 6 of11 lNot Observable [ruot Applicable Complies Does Not Ducts declared to be within the conditioned space are either 1) completely within the cantinuous air barrier and within the building thermal envelope, 2) buried within ceiling insulation in accordance with Section R403.3.6 and the air handler is located completely within the continuous air barrier and within the building thermal envelope and the duct leakage is <= 1.5 cfm / 100 square feet of conditioned floor area served by the duct system, or 3) the ceiling insulation R-value installed against and above the insulated duct >= to the proposed ceiling insulation R-value, less the R- value of the insulation on the HVAC piping conveying fluids above 105 qF or chilled fluids below 55 eF are insulated to >R- 3. R-R-_ nruot icable nNot Observable Complies Does Not 403.4.1 lFR24l1s nComplies EDoes Not ENot Observable INot Applicable Protection of insulation on HVAC piping. EComplies EDoes Not ENot Observable ENot Applicable R-R-Hot water pipes are insulated to >R-3. Automatic or gravity dampers are installed on all outdoor air intakes and exhausts. flComplies nDoes Not ENot observable ENot Applicable Additional Com ments/Assumptions: Low lm (Tier 3)1 Hi (Tier l-)Medium lmpact (Tier 2) Project Title: McDermott Residence 5322 COUNTY ROAD 243 Data filename: Report date: 09116124 Page 7 of1l. All installed insulation is labeled or the installed R-values provided. plies ENot Applicable Does Not Not Observable 402.L.t, 402.2.5, 402.2.6 ilN3lig iIComplies iEooes lrtot ilwot observable iENot Applicable see fhe Envelope Assemblies table for values R-R- Wood Mass Steel Wood Mass Steel Wall insulation R-value. lf this is a ss wall with at least a/z of the wall insulation on the wall exterior, the exterior insulation requirement applies (FR10). I EComplies EDoes Not ENot Observable !Not Rpplicable Wall insulation is installed per manufacturer's instructions. 303.2 llN4l1 Additional Comments/Assumptions: Medium lm ct (Tier 2)Low lm (Tier 3)t High lmpact (Tier 1) ProjectTitle: McDermott Residence 5322 COUNTY ROAD 243 Data filename: Report date: 09116124 Page 8 of1l. 402.1.L, 402.2.t, 402.2.2, 402.2.6 I Fr 1]1 IComplies lDoes Not ENot Observable Ceiling insulation R-value.See fhe Envelope Assemblies table for values. Not Applicable R-_ ! wood ! Steel R-_ ! Wood ! Steel 303.1.1.1-, iCeiling insulation installed per303.2 lmanufacturer'sinstructions. lFl2l1 iBlown insulation marked every i300 ftr. I !complies nDoes Not ENot Observable DNot Applicable Vented attics with air permeable insulation include baffle adjacent to soffit and eave vents that extends over insulation. . EComplies lDoes Not nNot Observable nNot npplicable Attic access hatch and door insulation >R-value of the adjacent assembly. R-402.2.4 lFt3l1 EComplies EDoes Not !Not Observable nNot epplicable R- Blower door test @ 50 Pa. <=5 ach in Climate Zones 1-2, and <=3 ach in Climate Zones 3-8. EComplies EDoes Not ENot Observable !Not Applicable ACH 50 =ACH 50 =402.4.1.2 lFt1711 Ducts are pressure tested to determine air leakage with either: Rough-in test: Total leakage measured with a pressure differential of 0.1 inch w.g. across the system including the manufacturer's air handler enclosure if installed at time of test. Postconstruction test: Total leakage measured with a pressure differential of 0.L inch w.g. across the entire system including the manufacturer's air handler enclosure. cfm/100 cfm/100 ft2 ftz-iesCompl403.3.3 lFt2711 iEoo"t wot inruot observable inNot Applicable Duct tightness test result of <=4 cfm/100 ft2 across the system or <=3 cfm/100 ft2 without air handler @ 25 Pa. For rough-in tests, verification may need to nComplies EDoes Not INot Observable nNot npplicable cfm/100cfm/100F_F- ro nraFmlnsduoccur 403.3.4 lFt4l1 Air handler leakage designated by manufacturer at <=2o/o of design air flow. 403.3.2.r lFt2411 Not Observable Not Applicable lDoes Not Complies Programmable thermostats installed for control of primary heating and cooling systems and initially set by manufacturer to code specifications. Does Not Not Observable Not Applicable Heat pump thermostat installed on heat pumps. plies Does Not Observable Applicable Circulating service hot water c\/cf6mc hrrro rr rfnmrf ir nr plies accessible manual controls nNot Observable i Dtrtot icable ; ii, , r,Lt! I i i.. ir;..ll' I .,,), 1 i r,. r,: 1 ht r1ct Medium 2t Low lm ct (Tier 3) Project Title: McDermott Residence 5322 COUNTY ROAD 243 Data filename: Report date: OglL6l24 Page 9 ofLL All mechanical ventilation system fans not part of tested and listed HVAC equipment meet efficacy and air flow limits per Table R403.6.1. Does Not Not Observable Not Applicable plies Hot water boilers supplying heat through one- or two-pipe heating systems have outdoor setback control to lower boiler water temperature based on outdoor temperature. INot Observable nNot Applicable Heated water circulation systems have a circulation pump. The system return pipe is a dedicated return pipe or a cold water supply pipe. Gravity and thermos- syphon circulation systems are not present. Controls for circulating hot water system pumps start the pump with signal for hot water demand within the occupancy. Controls automatically turn off the pump when water is in circulation loop is at set-point temperature and no demand for hot water exists. nComplies lDoes Not nNot Observable nNot Applicable Electric heat trace systems comply with IEEE 515.1 oJ UL 51"5. Controls automatically adjust the energy input to the heat tracing to maintain the desired water temperature in the piping. nComplies EDoes Not INot Observable INot Applicable Demand recirculation water systems have controls that manage operation of the pump and limit the temperature of the water entering the cold water pipinq to <= 104sF. nComplies nDoes Not ENot observable nNot Applicable Drain water heat recovery units tested in accordance with csA 855.1. Potable water-side pressure loss of drain water heat recovery units < 3 psi for individual units connected to one or two showers. Potable water- side pressure loss of drain water heat recovery units < 2 psi for individual units connected to three or more showers. plies Does Not Not Observable Not Applicable 9Oo/o or more of permanent fixtures have high efficacy lamps 404.L lFt6ll jFuel gas lighting systems havejno continuous pilot light.. plies Not Observable Applicable Compl ia nce certificate posted. nNot Applicable L (Tier 1)H Medium (Tier 2)Low lm ct (Tier 3) Project Title: McDermott Residence 5322 COUNTY ROAD 243 Data filename: Report date: 0911.6124 Page L0 ofLL [-lComplies EDoes Not !Not Observable nNot Applicable Manufacturer manuals for mechanicdl and water heating systems have been provided. Additional Comments/Assumptions: 1 hlm ct (Tier 1)Medium lm act (Tier 2)Low I (Tier 3) Project Title: McDermott Residence 5322 COUNTY ROAD 243 Data filename: Report date: O9lL6l24 Page 11 oflL 2018 IEGC Energy Efficiency Gertificate Above-Grade Wall Below-Grade Wall Floor Ceiling / Roof Ductwork (unconditioned spaces): Window Door Heating System Cooling System Water Heater: Name: Comments 20.oo 25.OO ro.oo 49.OO o.27 o.27 Date: lnsulation Rating R-Value Glass & Door Rating U-Factor SHGC Heating & Cooling Equipment Efficiency t