Loading...
HomeMy WebLinkAboutCorrespondence10128124,11:38 AM il Outlook Mail - Colleen Wirth - Outlook Re: BLRE-09-24-8919 / HERRERA 177 Eagle Ridge Dr is now UNDER REVIEW From Luis Vargas Herrera <umbllc2020@gmail.com> Date Mon 10/28/2024 1 1:37 AM To ColleenWirth <cwirth@garfield-county.com> 0J 1 attachments (9 KB) image001.png; The ENERGYCOMPLIANCE PATH forthis home is PRESCRIPTIVE PATH using 2018lECC and Table R402.1.2 Thank you, Luis Vargas Herrera On Fri, Oct 25, 2024,3:23 PM Colleen Wirth <cwirth@garfield-county.com> wrote BLRE-09-24-8919 / HERRERA 177 Eagle Ridge Dl Lot 31 Hello Luis, This is Colleen Wirth, Garfield County Plans Examiner. Your code compliance review is going fairly well. I do not have specific plan sheet corrections for you at this time. On Monday, I anticipate finishing the PUD GUIDE / zoning review for Lot 31 CORRECTION : FYI The WRIGHTSOFT Manual J Report from Rapid Creek Mechanical dated September 25,2024 appears to have an error on it. Garfield County has adopted a winter design temperature of MINUS 2 degrees F, for all properties up to 7,000 ft in site elevation. See REQUIREMENTS attached PDF \ $ {e $s https://outlook.office.com/mail/inbo/id/AAMkADQ3MWUI MDZkLTZmMDYtNDc2YyOSMGZjLWM30DQI MGU3Y2MxZABGAAAJ\A/\BIODKogAt9SaHl. .' 112 10128124,11:38 AM Mail - Colleen Wirth - Outlook Unfortunately, the MANUAL J report supplied for this particular lot seems to suggest a higher WINTER DESIGN TEMP of +6.6 or +7 degrees F. We're concerned the design may be inadequate for the site, and ask that you reach out to your MECHANICAL CONTRACTOR / SUPPLY HOUSE. Have them prepare an AMENDED AND CORRECTED MANUAL J REPORT for us to scan into the building file. When available, PROOFREAD the REVISED MANUAL J REPORT -- make sure CORRECTIONS have been made with no typos as I'd like to avoid any further delays in processing your building permit. Please also confirm in writing your specific ENERGY COMPLIANCE PATH for this hcme is PRESCRIPTIVE PATH using 2018 IECC and Table R4O2.1.2. While 2018lECC reference content is shown on your architectural sheets, NO ACTUAL WRITTEN STATEMENT was found on page(s) to CONFIRM your selected ENERGY PATH??? Garfield County Building staff do not wish to dictate for you which path you build to; we hope to make it clear for the building inspector so they can efficiently complete your inspections without question or guessing if "trade offs" apply. Please confirm in an email response to Colleen Wirth, Plans Examiner, cwirth@garfield- county.com for our building file record. Thank you fnllaan lAfir+hvvrlbb!r rrta gt! Building Plans Examiner Garfield County Community Development 108 8th Street, Suite 401 (970) 945-1377 ext 1610 CLARI FICATION QU ESTIO N: cwi rth @ oa rfi el d - cou ntv.com https://outlook.office.com/mail/inboxiid/AAMkADO3MWUI MDZkLTZmMDYtNDc2Yy05MGZjLWM3ODOI MGU3Y2MxZABGAAAAAABtODKogAtgSaHI. .. 212