HomeMy WebLinkAboutApplicationGurfield County
Community Development Department
108 8th Street, Suite 401
Glenwood Springs, CO 81601
leTols4s-82L2
www.garfield-countv.com
d
BUILDING PERMIT
APPLICATION
TVPE OF CONSTRUCTION
tr Commercial/Multi-Family tr Demolition
tr Manufactured Home or Tiny Home (single or Multi-Level)
tr Residential (SF, Duplex or Townhome)tr Reroof
- MAXIMUM SIZE OFDwellinUnit SQUARE FEETE
PARTIES
Property Owner:
Mailing Address:
Email Address:
TODD CHAPMAN
291 CR I 19, GLENWOOD SPR|NGS, CO 81601
POOLSCUM@YAHOO,COM
Phone: ( 303)BB5-9369
29r CR r r 9, GLENWOOD SPRTNGS, CO 8r601
POOLSCUM@YAHOO.COM
303Phone
Mailing Address:
Email Address:
Contractor: TODD CHAPMAN
Architect: ANDREW BICK- BICK ARCHITECTURE Phone: 1 Z0B)
PO BOX 9876, BOTSE, tD 83707
AKBICK@GMAIL.COM
726-8608
Mailing Address
Email Address:
JOCK MACGREGOR- MACGREGOR ENGINEERING &
Engineer: DESIGN, LLC Phone
9376W WILDBRANCH DRIVE, STAR,ID 83669
JOCKMACGREGOR220@GMAIL.COM
208 999-2ssi
Mailing Address:
Email Address:
Phone: ( )Manufactured/ Tiny Home Installer:
Mailing Address:
Email Address:
PROJECT DETAITS
AN APPROXIMATELY I2,OOOSF. GARAGE/WORK SPACE WITH l,OOO SF ACCESSORY DWELLING UNIT.
CONSTRUCTION SHALL CONSIST OF CONCRETE STEMWALL AND FOOTING AND CONCRETE PAD @
Describe Work: !44!!.LE=VEL, ENGINEERED FLoOR JOIST, WooD sTUD WALL FRAMING, slPS WALL PANEL WALLS oN
EXTERIOR. ENGINEERED SIP PANEL @ ROOFING SYSTEM WITH ASPHALT SHINGLE ROOFING MATERIAL.
Job Address: 291 CA RD 1 19, GLENWOOD SPR|NGS, CO Bl60t
owner's Valuation of Work: 5 100,000 Property Size (Sq. Ft. or Acres):
2 r 873020 I 00 I
SECTION 30, TOWNSHIP 6, RANGE 88
10. r 75 AcRES
25',-7 t /2"
Lot
2Height:
INTERIOR FJN ISHES INCLUDE GYPSUM BOARD AND VARIOUS FINISHES.
# of FlooSq. Ft. of Building:3000
Assessor's Parcel Number
sub. cHR|STELETT SUB AMD
Class of Work:E New E Remodel/Alteration E Rddition E Repair tr Move/Relocation
PROJECT DETAITS CONTINUED
Septic:E OWTS E Community
Type of Heat:E Natural Gas E Propane E Electric E other
Driveway
Permit:
E Exempt EXISTING DRIVEWAY ALREADY
INSTALLED.
E Permit #
NOTICE
Authoritv. This application for a Building Permit must be signed by the Owner of the property, described above,
oranauthorizedagent. lfthesignaturebelowisnotthatoftheOwner,aseparateletterofauthority,signedby
the Owner, must be provided with this Application.
Lesal Access. ABuildingPermitcannotbeissuedwithoutproofof legal andadequateaccesstothepropertyfor
purposes of inspections by the Building Division.
Other Permits. Multiple separate permits may be required: (1) State Electrical Permit, (2) County OWTS Permit,
(3) another permit required for use on the property identified above, e.g. State or County Highway/ Road Access
or a State Wastewater Discharge Permit.
Void Permit. A Building Permit becomes null and void if the work authorized is not commenced within 180 days
of the date of issuance and if work is suspended or abandoned for a period of 180 days after commencement.
CERTIFICATION
I hereby certify that I have read this Application and that the information contained above is true and correct. I understand
that the Building Division accepts the Application, along with the plans and specifications and other data submitted by me or
on my behalf (submittals), based upon my certification as to accuracy. Assuming completeness of the submittals and
approval of this Application, a Building Permit will be issued granting permission to me, as Owner, to construct the
structure(s) and facilities detailed on the submittals reviewed by the Building Division. ln consideration of the issuance of the
Building Permit, I agree that I and my agents will comply with provisions of any federal, state, or local law regulating the
work and the Garfield County Building Code, OWTS regulations and applicable land use regulations (County Regulation(s)).
All County development requiring a permit, except for residential uses, are subject to Article 7 of the Land Use and
Development Code. I acknowledge that the Building Permit may be suspended or revoked, upon notice from the County, if
the location, construction or use ofthe structure(s) and facility(ies), described above, are not in compliance with County
Regulation(s) or any other applicable law.
I hereby grant permission to the Building Division to enter the property, described above, to inspect the work. I further
acknowledge that the issuance of the Building Permit does not prevent the Building Official from: (1") requiring the correction
of errors in the submittals, if any, discovered after issuance; or (2) stopping construction or use ofthe structure(s) or
facility(ies) if such is in violation of County Regulation(s) or any other applicable law. Review of this Application, including
submittals, and inspections of the work by the Building Division do not constitute an acceptance of responsibility or liability
by the County of errors, omissions, or discrepancies. As the Owner, I acknowledge that responsibility for compliance with
federal, state, and local laws and County Regulations rest with me and my authorized agents, including without limitation my
architect designer, engineer and/ or builder.
I hereby acknowledge that I have read and understand the Notice and Certification above, as well as, have
provided the required information which is correct and accurate to the best of my knowledge.
TODD CHAPMAN
' 4.tt', s /15/2024
Property Owner Print and Sign Date
OFFICIAT USE ONLY
Special Conditions:
^ee
nt*ach€l GZ/VD fn A Ns
Adiusted Valuat
t3q- qn{ton:eo Plan Check Fee
7q ),5r Permit Fee:--lzl7, /-Manu home Fee:Misc Fees:sf aBD *tqz4
Total Fees:
LCCq,21
Fees Paid:ag+30 Balance Due: -l22l , v'f g*te-F.8?oc OWTS No:sE.sge\
Setbacks:
-
OCC Group:IRO constrvnT
R c ZoninC?
I n-2qBUttDtNG / PTANNtNG DtVtStON :
Signed Approval Date
Gnrfiefid CouwtY'
BIIILDING DEPARTMENr
7o8 Eighth Street, Saite AOt, Gtenwood Sprlngs' CO 81607
Tel: (970) 945-8272
PI.^AN REV IE wc HE CK LIST
Permit No: ELRH?*4-}7AA
Pl a n n ing I Zoning lssues
zr.rw 4bqBuilding lssues
erish
*7
Engineered Fou*datlon
e-XqnPb
Driveway Fermit
Surveyed Site Plan
,
UilPteptic Permit and setbacks
Grade/ TopograPhY 30%
Attach Residential Plan Review List
SuMivlsion Flat Notes
Fire Department Review
Valuation Determination/ Fees
Red Line Plans/ StamPs/ Sticker
QNDottach conditions
Application Signed
nia,r.Tailco/a-e T
r 3?a?z
KtFEB,>.
Flood Plain
Building Height
Zoning Sign-Off
Road lmpact Fees EB D
Grade/ ToPograPhY 40%
Planning lssues
Subdivision Plat
on & Summa rv:D ripti
n
Parcel/ Schedule No.
40# Snowload Letter - Manuf. Homes
1/*@x -- a/aa2
"f/./ /d?x ,z /
FLs /apxH68 =7t6a
5Z
/Z
t.z
Soils
t-l[:.,1:i'j-iiil'"i; ':r; :ii "'i i r1-'li:i 1;:,;
l :;l l:,,;:li ji r i i:ri : 1 .:''\\ ; ; : iiflTlfl(.'l'
ip45p,i:qy"i{,)11 l€aA, .i:il"
ra/aa/Zh /3'oa
ENERGY COMPLIANCE SHEET REQUIREMENTS:
Effective June 30, 2023 Please provide details showing how building complies / meets Garfield County's
adopted 2018 IECC and @!9.'.@!.
Depict and show outline the structure's building thermal envelope. Outline should clearly show portions
of the building to be conditioned inside the envelope (and label or otherwise identify any areas remaining
unconditioned outside this envelope)
Energy Compliance Plan should further include:
Chosen Energy Compliance Path. Prescriptive: Cross Sections of insulated assemblies including the selected material/ R-Value
and U-Values to comply with IRC Table R402.1.2. U-Factor Alternative: Provide a ResCheck Report. Total U-Factor Alternative: Provide software generated submittal design reports and inspection
checklist for any RESNET ERI index or other performance path designs
Air sealing details around openings, pipes, penetrations, joints
Fenestration U-factors
Provide mechanical system design details including proposed efficiency rates, types of equipment, fuel
types, locations
Energy efficient lighting specifications - 90% to be high-efficacy (LED complies)
Manual J Report required for new building structures and new equipment installations.
STRUCTURAL PLANS: Please provide the following information on the structural plans.. SOILS REPORT - lf the project is located in a subdivision with a final plat requiring site specific
soils investigation report or if Structural plans make a specific reference to a soils report, then a
copy of the soils report is required to submit a building permit application.. Design specifications to include roof and deck snow load, wind and seismic design and frost
depth.. Foundation plan showing complete footing and foundation dimensions.r Footing and foundation details specifying reinforcement and referenced on plans.. Framing plans for each floor level and roof. All beams, columns, joists, rafters and trusses
specified. Pre-manufactured structures require the engineers stamp, signature and date.. Framing /connection details, braced wall lines, shear wall schedule, location and hold downs.
NOTE: lf any required information is missing, delays in issuing the permit are to be expected. lf
determined by the Building Official that additional information is necessary to review the application
and/or plans for compliance, the application may be placed on hold until the required information is
provided. Work may not proceed without the issuance of a permit.
The Building Division will collect a Plan Review fee at time of application submittal. The permit fee, as
well as any Road lmpact fees will be collected when the permit is issued.
The permit application must be signed by the owner or by person having written authority from the owner
to act as their representative.
Building cannot be occupied until a Certificate of Occupancy (CO) is issued. Using the building without a
CO will be considered an i and be rounds for the rses.Final/CO
requrreme WI to your set of plans.)
I hereby acknowledge I have read, understand and will abide by the requirements of this
checklist.
Owner Print:
TODD CHAPMAN
Sign Date
5/15/2024