Loading...
HomeMy WebLinkAboutBolt Inspection ReportMonument Steel Inspection, LLC. Woldinrl, Mechanical Fastening, and Industrial Adhesive Inspection, P.O.Box 23388 Glade Park, CO. 81523 Phone: 318-469-2279 Email — monumentsteelinspectionllc22 cDgmail.com TO: Mr. James Passchier Level Buildco 138 Sunlight Dr. Glenwood Springs, CO 81601 Field inspection for 56 Gossamer Rd. 6-3-2024 QUANTITY DESCRIPTION 4 hrs Travel and inspection time 1 hr 100 miles Report time Mileage chg. INVOICE Invoice #: 540 Date: 6-3-2024 UNIT PRICE TOTAL $82.00/hr $328.00 $82.00/hr $82.00 $0.67/mi $67.00 TOTAL DUE ON RECEIPT OF INVOICE $477.00 Make all checks payable to Monument Steel Inspection, LLC. Or Send payment through Venmo - @welderbrik If you have any questions concerning this invoice, contact Daniel Bricker, 318-469-2279. Late fees totaling 5% will be accrued after 30 days of non-payment. Additional fees may result after 60 days of non-payment. THANK YOU FOR YOUR BUSINESS! MONUMENT iTEEL rNSPE ON, Mr. James Passchier Level Buildco 138 Sunlight Dr. Glenwood Springs, CO. 81601 Re: 56 Gossamer Rd. Glenwood Springs, CO. Dear Mr. Passchier, 6-3-2024 Permit#: BLRE-04-23-8056 As requested, structural steel special inspection was conducted per the IBC 2015 Edition - Chapter 17: Structural Tests and Special Inspection and the Garfield County requirements. I arrived on -site at 9:00 AM. I met with Mr. Scott Baltzer from your office to review project requirements and material ready for inspection. I have reviewed the welders' certifications and the welding procedures and found them to be acceptable. Visual weld inspection was conducted on the main floor level of the residence. I observed the bent beam arches (x2) of the great room off the entrance foyer and the beam/column header for the glass doors in the adjacent room. I observed bearing plate to beam fillet welds, the beam to miter plate fillet welds, and the beam to bucket fillet welds. Upon completion, I observed all welds to be in compliance with project specifications and the visual inspection requirements as stated in Clause 8 of the AWS D1.1 Structural Welding Code - Steel: 2020 Edition. High strength bolt inspection was conducted on the main floor level of the residence. I observed the bent beam arches (x2) of the great room off the Monument Steel Inspection, LLC Glade Park, CO 81523 318.469.2279 monumentsteelinspectionllc22@gmail.com entrance foyer and the beam/column header for the glass doors in the adjacent room. I observed all bolts to be 3/4" ASTM A325 plain body bolts fitted with a hardened flat washer properly positioned under the turning surface of a heavy hex nut. The pretension procedure was followed for the bent beam to column connection. All bolts were checked for tightness with a wrench. Upon completion, I observed all bolts to be in compliance with project specifications and the inspection criteria of the American Institute of Steel Construction (AISC) and the Research Council on Structural Connections (RCSC). Anchor bolt inspection was conducted on the crawl space and main floor level of the residence. All anchor bolts were checked for tightness with a wrench. Upon completion, I observed all anchor bolts to be in compliance with project specifications. This final inspection concludes the steel erection phase of this project.Dr Respectfully submitted, 40'�-4ek- Dan Bricker, CWI AWS CWI #09052051 Monument Steel Inspection Monument Steel Inspection, LLC PO Box 23388 Glade Park, CO 81523 318.469.2279 monumentsteelinspectionllc22@gmail.com