Project Address: 4300 Bear Paw LN, Glenwood Springs, CO 81601 Parcel No.: _218517400152
Owner Name: Constance and Thomas Russello Owner Phone: (571) 237-4827
Designed By: CBO, Inc. & K-Cronk Engineering Designer Phone: (970) 309-5259
Number of bedrooms: 5 Minimum Tank Capacity: 1,500-gallon Minimum Absorption: 960 ft2
OWTS PERMIT
KEEP AVAILABLE AT PROJECT SITE
Permit Number _SEPT-8962_______________________________
Permit Type X New X Repair X Remodel/addition X Tank only
Issue Date _11/18/2024____________________ Expiration Date _11/18/2025_________________
Permit Conditions:
This OWTS Permit is approved on the condition of compliance with the report and design as submitted by
CBO, Inc. and K-Cronk Engineering on July 29, 2024. Changes to the design and permit must be approved
by Garfield County Public Health and the designer prior to construction.
The new OWTS will serve a new 5-bedroom residence. The new OWTS components will consist of a new,
two-compartment 1,500-gallon septic tank set level with access to grade and an effluent filter installed in
the outlet tee of the tank followed by a 500-gallon single-compartment pump chamber with a high-head
pump in the pump chamber. Effluent will be pumped to an Automatic Distributing Valve (ADV) set at the
high point of the system that will distribute effluent to 960 ft2 of STA. The new STA will consist of five
gravelless chamber trenches, each trench consisting of 16 Quick4 chambers per trench (80 chambers
total). The pump line and distribution laterals are to be 1.5-inch Schedule 40 PVC, with 5/32-inch orifices
3-feet on center and the laterals ending in 90-degree sweeping bends and flushing valves at the distal end
of the laterals. Laterals are to be hung from the underside of the chambers with zip-ties. The orifices are
to be facing upward with the exception of the first and last orifices that will face downward (with orifice
shields) for drainage. Inspection ports are to be installed at each end of each trench. Maintain all
setbacks and elevations as designed.
To assist in scheduling, please contact Garfield County Public Health (970-945-6614 ext. 8150) to notify
the start of OWTS construction. Contact the designer and Garfield County Public Health at least 48 hours
prior to requesting final inspection of the installed system prior to backfill. NO OWTS COMPONENT SHALL
BE BACKFILLED WITHOUT PRIOR APPROVAL FROM GARFIELD COUNTY PUBLIC HEALTH AND THE
DESIGNER.
Agreement
All installations must comply with all requirements of the Garfield County OWTS regulations
including but not limited to the conditions specified above.
In consideration of the issuance of the permit, the applicant hereby agrees to comply with all
laws and regulations related to the zoning, location, construction, and erection of the proposed
OWTS and associated structures for which this permit is granted. The applicant further agrees
that if the above said regulations are not fully complied with in the zoning, location, erection,
and construction of the above described OWTS and structure, the permit may then be revoked
by notice from the Health Department and immediately become null and void.
The issuance of a permit and specifications of terms and conditions therein will not constitute
assumption of liability, nor create presumption that the local public health agency or its
employees may be liable for the failure or malfunctioning of any system. Permit issuance will
not constitute a certification that the system, the equipment used in the system, or any
component used for system operation will ensure continuous compliance with the provision of
the OWTS Act, the regulations adopted thereunder, or any terms and conditions of a permit.
Permit Approval
Plans and specifications for the proposed OWTS have been reviewed and are considered
satisfactory. Permission is hereby given to the property owner(s) to perform the work indicated
in accordance with the Garfield County OWTS Regulation. This Permit will expire 1 year from
the date of issuance unless construction on the system has commenced. An "as-built" drawing
must be submitted and inspection of the system must be completed by GCPH before final
approval of the system will be issued.
11/18/2024
Issued By: Garfield County Environmental Health
Department
Date