The following insulation was installed by Mountain Peak Insulation LL P:
R-49 Spray foam insulation to ceiling (4.5 inches of foam) and R-19 unfaced batts no vented roof
R-49 Loose fill insulation to all flat truss ceiling to the rest of the house and care taker unit
R-21 unfaced batts batt insulation to all 2x6 exterior walls with 6 mil vapor barrier
R-11 unfaced batt insulation to all 2x4 interior walls
R-19 unfaced batt insulation to all 2x6 interior walls
R-21 unfaced batt insulation to all garage common walls with 6 mil vapor barrier
R-38 Loose fill insulation to all garage ceiling with perimeter baffles
R-19 unfaced batt insulation to basement ceiling
R-15 rockwool insulation to crawl space ceiling due to height
R-19 roll insulation to crawl space walls mechanically fasten
6 mil vapor barrier to crawl space floor glued at stem walls and in between seems
Fire foam penetrations , door, windows
Declarations: I hereby certify that the above insulation was installed in the building at the above location in
Conformance with the current Energy Efficiency standards for residential building Energy Code
Mountain Peak Insulation LLP.
Mountain Peak Insulation
5033 County Rd. 335 #33
New Castle CO. 81647
Tony Chavez