Loading...
HomeMy WebLinkAboutPermit Card (Renewed) Garfield County Public Health 2014 Blake Ave. Glenwood Springs, CO 81601 Phone: (970) 945-6614 ext. 8150 For inspections, call: 970-945-6614 ext. 8150 and call the Design Engineer, if applicable Project Address: 6762 Hwy 82 Glenwood Springs, CO 81601_ Parcel No.: _239501100011 Owner Name: Thunder Ridge Business Owner Phone: (970) 948-2810 Designed By: CBO Designer Phone: (970) 309-5259 Number of Bedrooms: _0_ Minimum Tank Capacity: 1,000-gallon Minimum Absorption: 300 ft2 OWTS PERMIT KEEP AVAILABLE AT PROJECT SITE Permit Number _SEPT-8107 (Renewed)____________________________ Permit Type X New X Repair X Remodel/addition X Tank only Issue Date _11/19/2024____________________ Expiration Date_11/19/2025_________________ Permit Conditions: This OWTS Permit is approved on the condition of compliance with the report and design as submitted by CBO dated February 22, 2023 and revised June 15, 2023. Changes to the design and permit must be approved by Garfield County Public Health and the designer prior to construction. The new OWTS will serve two new office buildings with up to sixteen 8-hour employees total. The existing buildings are to be demolished. The existing OTWS will be removed and or abandoned in place. The new system will consist of a new, two-compartment 1,000-gallon septic tank set level with access to grade followed by a pump chamber set level with access to grade and a high-head pump in the pump chamber. Effluent will be pumped to an automatic distributing valve set at the high point of the system that will distribute effluent to 438 ft2 of STA. The new STA will consist of an unlined sand filter, consisting of 2 feet of sand and three laterals to be covered in washed gravel, 12- feet wide by 37 feet long. Distribution laterals are to be 1 ½ inch Schedule 40 PVC, with 5/32-inch orifices 3 feet on center and the laterals ending in flushing valves at the distal end of the laterals. Inspection ports are to be installed at each corner of the bed. Maintain all setbacks and elevations as designed. Contact the designer and Garfield County Public Health at least 48 hours prior to requesting final inspection of the installed system prior to backfill. Agreement All installations must comply with all requirements of the Garfield County OWTS regulations including but not limited to the conditions specified above. In consideration of the issuance of the permit, the applicant hereby agrees to comply with all laws and regulations related to the zoning, location, construction, and erection of the proposed OWTS and associated structures for which this permit is granted. The applicant further agrees that if the above said regulations are not fully complied with in the zoning, location, erection, and construction of the above described OWTS and structure, the permit may then be revoked by notice from the Health Department and immediately become null and void. The issuance of a permit and specifications of terms and conditions therein will not constitute assumption of liability, nor create presumption that the local public health agency or its employees may be liable for the failure or malfunctioning of any system. Permit issuance will not constitute a certification that the system, the equipment used in the system, or any component used for system operation will ensure continuous compliance with the provision of the OWTS Act, the regulations adopted thereunder, or any terms and conditions of a permit. Permit Approval Plans and specifications for the proposed OWTS have been reviewed and are considered satisfactory. Permission is hereby given to the property owner(s) to perform the work indicated in accordance with the Garfield County OWTS Regulation. This Permit will expire 1 year from the date of issuance unless construction on the system has commenced. An "as-built" drawing must be submitted and inspection of the system must be completed by GCPH before final approval of the system will be issued. 11/19/2024 Issued By: Garfield County Environmental Health Department Date