HomeMy WebLinkAboutConditions of PermitCONDITIONS OF PERMIT
BLCO-10-24-8945
CCC-B LLLP
SUBMITTED AS A STORAGE WAREHOUSE
62 COUNTY ROAD 1 13 #I
TYPE IIB CONSTRUCTION, S-1 OCCUPANCY
1) SEPARATE PERMITS REOUIRED FOR TENANT FINISHES.
2) IF ANY AREA IS LEASED BY SEPARATE TENANTS, ADDIIONAL RESTROOMS ARE
REQUIRED.
3) THE APPROVED PLANS ARE TO BE ON-SlrE FOR INSPECTIONS.
4) SANTTARY FACTLTTTES ARE REOUIRED TO BE PROVIDED FOR WORKERS.
5) A LIST OF REOUIRED INSPECTIONS WILL BE ATTACHED TO THE PLANS. THE STATE
IS TO PERMIT AND APPROVE THE ELECTRICAL WORK,
RMITS
6) UNDERGROUND UTrLrry LOCATES rS THE RESPONSTBTLTry OF THE OWNER OR
CONTRACTOR. 811 IS THE COLORADO UTILITY LOCATE HOT LINE.
7) DRAINAGE ACROSS PROPERry LINES SHALL NOT EXCEED THAT WHICH EXISTED
PRIOR TO GRADING. EXCESS OR CONCENTRATED DRAINAGE SHALL BE
CONTAINED ON SITE OR DIRECTED TO AN APPROVED DRAINAGE FACILIry.
EROSION OF THE GROUND IN THE AREA OF DISCHARGE SHALL BE PREVENTED BY
THE INSTALLATION OF NON-EROSIVE DOWN DRAINS OR OTHER DEVICES.
B) ALL BACKFLOW PREVENTERS ARE REOUIRED TO BE TESTED AND CERTIFIED BY A
LICENSED BACKFLOW SPECIALIST AFTER INSTALLATION AND PRIOR TO ISSUANCE
OF THE CERTIFICATE OF OCCUPANCY.
9) SEPARATE SIGN PERMITS ARE REOUIRED FOR ANY EXTERNAL SIGNS. PLEASE
CONTACT THE COUNTY PLANNER FOR THE APPLICATION.
1O)ELECTRICAL CODE COMPLIANCE WILL BE DETERMINED BASED ON FIELD
INSPECTIONS PERFORMED BY THE STATE ELECTRICAL INSPECTOR, (303) 869-3458.
PLEASE HAVE THE INSPECTOR SIGN THE BUILDING CARD OR PROVIDE WRITTEN
DOCUMENTATION OF THE INSPECTIONS.
1 1)THE ELECTRICAL CODE REOUIRES A SEPARATE ELECTRICAL PERMIT FOR LOW
VOLTAGE FIRE ALARMS THAT HAS AN ALARM PANEL AND SEND A NOTIFICATION
STATE ELECTRICAL INSPECTOR IS REQUIRED (303) 869-3458. PLEASE HAVE THE
INSPECTOR SIGN THE BUILDING CARD OR PROVIDE WRITTEN DOCUMENTATION
OF THE INSPECTION.
12)THE FIRE SPRINKLER AND ALARM ARE REOUIRED TO BE INSPECTED AND
APPROVED BY THE LOCAL FIRE PROTECTION DISTRICT. PLEASE PROVIDE SHOP
DRAWINGS TO THE FIRE DISTRICT FOR REVIEW AND SCHEDULE THE INSPECTIONS
ACCORDINGLY. PLEASE HAVE THE FIRE MARSHAL SIGN THE INSPECTION CARD
WHEN THE ROUGH INSPECTION IS APPROVED AND WHEN THE FIt\AL INSPECTION
IS APPROVED.
13)ANY WATER SUPPLY THAT FEEDS A FIRE SUPPRESSION SYSTEM IS TO BE
INSPECTED BY THE FIRE MARSHAL FOR THAT FIRE DISTRICT PRIOR TO
BACKFILLING.
14)PLEASE PROVTDE SPECTAL TNSPECTTONS REPORTS TO THE BUTLDTNG
DEPARTMENT, WELDING AND BOLTING IS MINIMUM.
i 5)GEOTECHN|CAL OBSERVAT|ON rS REOUiRED WHEN THE EXCAVAT|ON iS
COMPLETE AND WRITTEN VERIFICATION BE SUPPLIED AT FOOTING INSPECTION,
2000PSF.
16)COMBUSTTBLE MATERTAL rS LTM|TED tN rypE r AND TYPE il CONSTRUCTTON. SEE
IBC 603 FOR ALLOWED COMBUSTIBLE MATERIALS.
17)ALL EXTERTOR LTGHTTNG rS TO BE DOWNCAST AND SHtELDED.
18)SAFETY GLAZING IS NOT DESIGNATED ON THE PLANS. SAFEry GLAZING WILL BE
cHECKED DURTNG THE FRAMTNG AND FTNAL |NSPECT|ON. (rBC 2406.4)
19)ANY MEMBRANE AND THROUGH PENETRATIONS OF THE FIRE RESISTIVE
CONSTRUCTION WILL BE REOUIRED TO BE FIRE-STOPPED WITH LISTED FIRE
STOPPING ASSEMBLIES. THE CONTRACTOR IS TO PROVIDE A CUT SHEET FOR THE
ASSEMBLTES AT THE FRAMTNG tNSPECT|ON. (tBC 713)
20)A KNOX BOX IS REOUIRED TO BE MOUNTED ADJACENT TO THE FRONT DOOR.
PLEASE CONTACT THE LOCAL FIRE DISTRICT FOR EXACT LOCATION.
21)lF THE FIRE SPRINKLER SYSTEM REOUTRES A FtRE PUMP. THEN THE UTtL|TY ROOM
THAT HOUSES THE PUMP WILL BE REOUIRED TO BE ONE-HOUR CONSTRUCTION.
(rBC TABLE s08.2.s)
22)THEWALLS SURROUNDTNG THE TOTLET ARE TO BE NON-ABSORBENT FOR A
HEIGHT OF 48" AND 2' PAST ON EACH SIDE OF THE TOILET.
23)ALL ACCESSIBLE DOOR HARDWARE SHALL HAVE A SHAPE THAT IS EASY TO GRIP,
TNCLUDtNG POCKET AND SLTDTNG DOORS. (ANS| A117.1 - 404,2.6)
24)GRAB BAR BACKTNG rS TO BE rN PLACE FOR nLL TO|LETS.
25)A PASSING BLOWER DOOR TEST IS REOUIRED TO BE SUBMITTED PRIOR TO
ISSUING THE CERTIFICATE OF OCCUPANCY.
26)AN ACCESSIBLE PARKING SPACE IS TO BE PROVIDED FOR THIS BUILDING.