HomeMy WebLinkAboutRes Check ReportGenerated by RESche ck-Web Software Com pl iance Certificate Project Schoeppner Guest House Energy Code: Location: Construction Type: Project Type: Conditioned Floor Area Glazing Area Climate Zone: Permit Date: Permit Number: All Electric ls Renewable Has Charger Has Battery: Has Heat Pump: 2018 tECC Garfield County, Colorado Single-family New Construction 4,OO8 ft2 l8o/" s (8499 HDD) false false false false false Compliance: 18,6% Better Than Code Maximum UA: 5O1 Your UA: 4O8 The % Better or Worse Than Code lndex reflects how close to compliance the house is based on code trade-off rules, It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Slab-on-grade tradeoffs are no longer considered in the UA or performance compliance path in REScheck. Each slab-on-grade assembly in the specified climate zone must meet the minimum energy code insulation R-value and depth requirements. Envelope Assemblies Construction Site: 7101 county road 117 GLENWOOD SPGS, CO 81601 Ceiling: Flat Ceiling or Scissor Truss Ceiling 1: Flat Ceiling or Scissor Truss Skylight: Metal Frame w/Thermal Break Wall: Wood Frame, 16" o.c. Door 1: Solid Door (under 50% glazing) Owner/Agent: Mark Schoeppner 7101 County Road 117 glenwood springs, co 81601 9706186690 cws.schoeppner@gmail.com Desig ner/Contractor: Brad Jordanjordan architecture inc. po box 1031 Glenwood Springs, CO 81602-1031 9706186690 bradjordanarchitect@gmail.com 0.026 0.026 0.280 0.042 0.200 $ -{.tts \ -N r,458 627 108 r,307 38 0.026 0.026 0.550 0.060 0.300 38 13 30 43 8 49.0 49.O 0.0 0.0 38 13 59 61 t2 Compliance: Passes using UA trade-off Gross Area or Perimeter Cavity R-Value Cont. R-Value Prop. Req. U-Factor U-Factor Req UAAssemblyProp. UA r43 29 74 20.0 6.0 Window: Wood Frame Window 1: Wood Frame Window 3: Wood Frame 0.280 0.280 0.280 0.300 0.300 0.300 40 43 8 9 2T 22 Project Title: Schoeppner Guest House Data filename: Report date: 06118124 Page i. of 10 Cavity R-Value Cont. R-Value Prop, Req. U-Factor U-Fa€tor Req. UA Gross Area Assembly or Perimeter Prop, UA Wall L: Wood Frame, 16" o.c. Door: Glass Door (over 50% glazing) Window 1:Wood Frame Wall 2: Wood Frame, 16" o.c. Door 1: Glass Door (over 50% glazing) Window 2: Wood Frame Wall 3: Wood Frame, 16" o.c. Door 2: Glass Door (over 50% glazing) Floor: Slab-On-Grade (Heated) lnsulation depth; 3,0' lnsulation position: Fully lnsulated (uniform R-value across perimeter and under slab) 588 24 29 1,200 66 282 57r 24 0.042 0.350 0.280 0.o42 0.350 0.280 0.042 0.350 0.060 0.300 0,300 0.060 0.300 0.300 0.060 0.300 22 8 8 36 23 79 23 I 32 7 I 51 20 85 33 7 20.0 6,0 20.0 6.0 20.0 6.0 236 15.0 0.440 0.645 0 0 Compliance Statementi The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meetthe 2018 IECC requirements in REScheck Version : REScheck-Web and to comply with the mandatory requirements listed in the REScheck lnspection Checklist. Name - Title Date Project Title: Schoeppner Guest House Data filename: Report date: O6lLBl24 Page 2 of 1"0 fr ffiff: I #i:i ;:: iii i J.= " n e c k we b Requirements: 0,0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, orthat an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Additional Comments/Assu mptions: Section # & Req.lD Pre-lnspection/Plan Review Plans Verified Value Field Verified Value Complies?Comments/Assumptions 103.1, 103.2 lPRlll .e Construction drawings and documentation demonstrate energy code compliance for the building envelope. Thermal envelope represented on construction documents. nComplies nDoes Not nNot Observable nNot Applicable 103.1, 103.2, 403.7 lPR3ll gl Construction drawings and documentation demonstrate energy code compliance for lighting and mechanical systems Systems servin g multiple dwelling units must demonstrate compliance with the IECC Commercial Provisions. nComplies nDoes Not ENot Observable flNot Applicable 302.1, 403.7 lPR2l2 'g/ Heating and cooling equipment is sized per ACCA Manual S based on loads calculated per ACCA Manual J or other methods approved by the code official. Heating: Btu/hr_ Cooling: Btu/hr_ Heating: Btu/h r_ Cooling: Btu/h r nComplies nDoes Not ENot Observable nNot Applicable 1 High lmpact (Tier 1)2 Medium lm (Tier 2)3 Low I (Tier 3) Project Title: Schoeppner Guest House Data filename: Report date: 06118124 Page 3 ofL0 Section # 6. Red.lD Foundatlon lnspectlon Plans Verlfled Value Fleld Verified Value Complies?Comments/Assumptlons 402.L.2 ,Slab edge insulation R-value lFoll1 Q R-R-:nComplies ;nDoes tttot lnNot observable iflruot npplicable ;See the Envelope Assemblies I Unheated ! Heated ! Unheated ! Heated table for values, 402.t.2 lFo3l1 s :Slab edge insulation :depthilength. ft ft tnComplies inDoes Not l[]ruot observable inNot Applicable 'See the Envelope Assemblies ',.,table for values. : 303.2.1 tFo1112 s A protective covering is installed to protect exposed exterior insulation and extends a minimum of 6 in. below grade. lJComplies IDoes Not ENot Observable flNot Applicable 403.9 lFo12l, rg) Snow- and ice-melting system controls installed. ncomplies nDoes Not nNot Observable nruot Applicable Additional Comments/Assumptions: 1 (Tier 1)Hi hlm 2 Medium lmpact (Tier 2)3 Low lmpact (Tier 3) Project Title: Schoeppner Guest House Data filename: Report date: OGlLBl24 Page 4 of10 Plans Verified Value Field Verified Value Complies?Comments/Assum ptionsSection # & Req.lD Framing / Rough-ln lnspection 402.r.\, 402.3.4 lFR1l1g !Complies nDoes Not nNot Observable nNot Applicable See the Envelope AssembliesDoor U-factor table for values. U-U- 402.r.r, 402.3.1, 402.3.3, 402.5 lFR2lt ,$_/ nComplies EDoes Not nNot Observable ENot Applicable See the Envelope Assemblies table for values. U-U-Glazing U-factor (area-wei ghted average). 303,1,3 lFR4ll 'S,. U-factors of fenestration products' are determined in accordance with the NFRC test procedure or taken from the default table. nComplies nDoes Not !Not Observable nNot Applicable 402.1.I, Skylight U-factor 402.3.3, 402.3.6, 402.5 lFR5l1 ,,vJ !Complies nDoes Not nNot Observable nNot Applicable See the Envelope Assemblies table for values. U-U- 402.3.5 lFRSlr .u Fenestration in thermally isolated sunrooms in Climate Zones 2-8 have maximum U-0.45. u-_ ! lsolated ! Not lsolated !Complies nDoes Not ENot Observable nNot Applicable U- ! lsolated ! Not lsolated 402.3.5 lFR9li ,.9r Skylights in thermally isolated sunrooms in Climate Zones 2-8 have a maximum skylight U- factor of 0.70. All other sunroom skylights must meet code requirements. u-_ ! lsolated ! ttlot lsolated u-_ ! lsolated n ruot lsolated nComplies IDoes Not nNot Observable nNot Applicable 402.4.r.1 lFR23l1 '9r Air barrier and thermal barrier installed per manufacturer's i n structi on s. !Complies nDoes Not !Not Observable !Not Applicable 402.4.3 lFR20l1 ,9J Fenestration that is not site built is listed and labeled as meeting AAMA /WDMA I CSA 70L ll.S.2 I 4440 or has infiltration rates per NFRC 400 that do not exceed code limits. nComplies nDoes Not !Not Observable nNot Applicable lC-rated recessed lighting fixtures sealed at housing/interior finish and labeled to indicate <2.0 cfm leakage at 75 Pa. nComplies nDoes Not nNot Observable nNot Applicable 402.4.5 lFR16l2 Supply and return ducts in attics insulated >= R-8 where duct is >= 3 inches in diameter and >= R-6 where < 3 inches. Supply and return ducts in other portions of . the building insulated >= R-6 for diameter >= 3 inches and R-4.2 for < 3 inches in diameter. nComplies nDoes Not INot observable !Not Applicable 403.3.1 lFR12l1 s, 403.3.2 lFR13l1 'qr Ducts, air handlers and filter boxes are sealed with joints/seams compliant with lnternational Mechanical Code or !Complies nDoes Not ENot Observable applicable. 1 hlm (Tier 1)2 Medium lmpact (Tier 2)3 ct (Tier 3)Low Project Title: Schoeppner Guest House Data filename: Report date: OGI)-9124 Page 5 ofL0 €omments/Assumptlonsj"-?A ir'"'lns / Roush-rn rnsne"tioni Plansveriried rield "ver*eo I complles? 403.3,5 lFR15l3 Q Building cavities are not used as ducts or plenums. nComplies nDoes Not lNot Observable flNot Applicable HVAC piping conveying fluids above 105 PF or chilled fluids below 55 sF are insulated to >R- 3. nDoes Not nNot Observable nNot Applicable R-R-Complies lFR1712 @ 403.4.1 lFR24l1 Q nComplies !Does Not nNot Observable !Not Applicable Protection of insulation on HVAC piping, 403.s.3 tFR18l2 s nComplies nDoes Not nNot Observable !Not Applicable RR-Hot water pipes are insulated to >R-3. 'Automatic or gravity dampers are installed on all outdoor air intakes and exhausts. EDoes Not Complies403.6 lFR19l2 ot Observable ot Applicable Additional Comments/Assumptions: 1 High lmpact (Tier 1)2 Medium lmpact (Tier 2)3 Low lmpact (Tier 3) Project Title: Schoeppner Guest House DaLa [ilerrarrre: Report date: 06118124 Page 6 ofL0 Plans Verlfled Valu6 Field Verified Value Complies?Comments/Assumptlons Sectlon # & Reo.lD lneulation lnspection nComplies nDoes Not nNot Observable nNot Applicable 303.1 [!N13]2 @ All installed insulation is labeled 'or the installed R-values provided, 402.t.L, 402.2.5, 402.2.6 ltN3l1g Wall insulation R-value. lf this is a mass wall with at least % of the wall insulation on the wall exterior, the exterior insulation requirement applies (FR10). R-_ ! Wood ! Mass [] Steel nDoes Not nNot Observable nNot Applicable table for values, R- ! Wood n Mass ! Steel !Complies See the Envelope Assemblies nNot Observable , nNot Applicable , nComplies nDoes Not Wall insulation is installed per manufacturer's instructions, 303.2 ltN4ll nComplies nDoes Not nNot Observable icable Sunroom wall insulation installed per manufacturer's lnstructions. 303.2 ltN9l1 ENot Applicable Observable plies Not Sunroom ceiling insulation is installed per manufacturer's instructions. 303.2 ltN 1111 Additional Comments/Assumptions: 1 (Tier 1)h 2 Medium lmpact (Tier 2)3 Low lmpact (Tier 3) Project Title: Schoeppner Guest House Data filename: Report date: OGlLBl24 Page 7 ofL0 S€ctlon # & Red.lD Flnal lnspectlon Provislons Plans Verlfled Value Fleld Verlfled Value Complles?Comments/Assumptions 4O2.L.I, Ceiling insulation R-value 402.2.1, 402.2.2, 402.2.6 I Ftl ]1 iEComplies ilDoes Not lnNot observable lnNot Applicable R-_ ! Wood ! Steel tR- nriiloo-O I ! Steel rSee the Envelope Assemblies 'table for values. 303.1.1.1, Celltng lnsulation installed per303.2 manufacturer's instructions.lFl211 ,Blown insulation marked every 300 ft'?. nComplies nDoes Not nNot Observable nNot Applicable Vented attics with air permeable insulation include baffle adjacent to soffit and eave vents that extends over insulation. 402.2.3 LFt22l2 !Complies nDoes Not nNot Observable lNot Applicable Attic access hatch and door insulation >R-value of the adjacent assembly. inComplies inDoes Not i[]Not observable lDNot Applicable 402.2,4 R.R. lFt3l1 Blower door test @ 50 Pa. <=5 ach in Climate Zones 1-2, and <=3 ach in Climate Zones 3-8. ACH 50 :ACH 50 = icable plies402.4.1.2 lFt 1711 iIDoes ltot inruot observable Ducts are pressure tested to determine air leakage with either: Rough-in test: Total leakage measured with a pressure differential of 0.1 inch w.g. across the system including the manufacturer's air handler enclosure if installed at time of , test. Postconstruction test: Total 'leakage measured with a 'pressure differential of 0.1 inch w.g. across the entire system 'including the manufacturer's air handler enclosure. cfm/100 cfm/l00ii-plies403.3.3 lFr2Tll inDoes ltot tlltot Observable ;nNot Applicable Duct tightness test result of <:4 cfm/100 ft2 across the system or <=3 cfm/l00 ft2 without air handler @ 25 Pa. For rough-in tests, verification may need to occur during Framing lnspection. ,nComplies i[]ooes Not ,INot Observable :INot Applicable cfm/100 cfm/100 ft2 403.3.4 lFt4lr Air handler leakage designated by manufacturer at <=2o/o of design air flow. !Complies nDoes Not nNot Observable nNot Applicable 403.3.',2,1 lFl24lr Programmable thermostats installed for control of primary heating and cooling systems and initially set by manufacturer to code specifications. nComplies nDoes Not nNot Observable nNot Applicable 403,1,1 lFt9l2 ncomplies nDoes Not !Not Observable nNot Applicable 403,L.2 IFtrolz Heat pump thermostat installed on heat pumps. Circulating service hot water systems have automatic or accessible manual controls. nComplies !Does Not !Not Observable nNot Applicable 403,5.1 lFt1112 1 ct (Tier 1)Im 2 Medium lm ct (Tier 2)3 Low I ffier 3) Project Title: Schoeppner Guest House Data filename: Report date: O6lLBl24 Page 8 of10 Plans Verified Value Field Verified Value Complies?Comments/Assumptions Section # & Req.lD Final lnspection Provisions All mechanical ventilation system fans not part of tested and listed HVAC equipment meet efficacy and airflow limits perTable R403.6.1. EComplies EDoes Not !Not Observable nNot Applicable 403.6.1 lFt2 5 l2 Hot water boilers supplying heat through one- or two-pipe heating systems have outdoor setback control to lower boiler water temperature based on outdoor tem perature. nComplies nDoes Not nNot Observable !Not Applicable 403.2 lFl26l2 Heated water circulation systems have a circulation pump. The system return pipe is a dedicated' return pipe or a cold water supply pipe. Gravity and thermos- syphon circulation systems are not present. Controls for circulating hot water system pumps start the pump with signal for hot water demand within the occupancy. Controls automatically turn off the pump when water is in circulation loop is at set-point temperature and no demand for hot water exists. 403.5.1.1 lFt28l2 !Complies lDoes Not nNot Observable ENot Applicable Electric heat trace systems comply with IEEE 515.1 or UL 5 15. Controls automatically adjust the energy input to the heat tracing to maintain the desired water temperature in the piping. EComplies nDoes Not nNot Observable nNot Applicable 403.5.r.2 lFt29l2 Demand recirculation water systems have controls that manage operation of the pump and limit the temperature of the water entering the cold water piping to <= 104qF. nComplies nDoes Not nNot Observable nNot Applicable 403.5.2 tFt30l2 Drain water heat recovery units tested in accordance with CSA B55.1. Potable water-side pressure loss of drain water heat recovery units < 3 psi for individual units connected to one or two showers. Potable water- side pressure loss of drain water heat recovery units < 2 psi for individual units connected to three or more showers. 403.5.4 lFt3 1 l2 IComplies nDoes Not nNot Observable ENot Applicable !Complies lDoes Not nNot Observable !Not Applicable 404.1 lFt6ll 90lo or more of permanent fixtures have high efficacy lamps. 404.t.1 lFt23l3 .{) nComplies nDoes Not nNot Observable nNot Applicable Fuel gas lighting systems have no continuous pilot light. 401.3 lFt712 nComplies nDoes Not Compliance certificate posted !Not Applicable 1 ht (Tier 1)2 Medium lmpact (Tier 2)3 Low lmpact (Tier 3) Project Title: Schoeppner Guest House Data filename: Report date: 06118124 Page 9 ofL0 mechanic€l aRd water heating ,sygtems have been provided, manuals fof' Ad.d itisnal GommentslAssumptions: Pr.ojeet Title Sclroeppner Gues-t House Data filename: Report daterr O6lLgl24 Page 10 of10 2018 IEGC Energy Efficiency Gertificate Above-Grade Wall Below-Grade Wall Floor Ceiling / Roof Ductwork (unconditioned spaces): Window Door Skylight Heating System Cooling System Water Heater: Name: Comments 26.00 o.oo 15.O0 49.00 o.2a o.35 o.2a Date: lnsulation Rating R-Value Glass & Door Rating U-Factor SHGC Heating & Cooling Equipment Efficiency