Loading...
HomeMy WebLinkAboutHUD InformationChampion Home Builders, lnc. 315 West Skyline Road ARKANSAS C|TY, KS 67005 Phone: 62042'9060 Fax: Bill To: 14B3CO Courlas Consulting, lnc. Midwest Homes 5585 Erindale Dr. Suite 200 Colorado Springs, CO 80918 Quote - Revision 6 No.: QT020949 Shipping Agent: Shipping County: FOB: EL PASO Factory Sell To: 1483CO Courlas Consulting, lnc- Midwest Homes 5585 Erindale Dr. Suite 200 Colorado Springs, CO 80918 Keith Courlas Ship To: Courlas Consulting, lnc. COLORADO SPRINGS, CO BO91B Variant Description Quote Date: Retailer P.O.: Order Type: Retail Customer: Req. Del. Date: Zone Manager: Brand: Model No.: Base Home: Model Year: Model Size: Construction Type: 09125124 Retail OYLER FAMILY Wayde Clark ,Prairie Dune 2 Premier LH28862 44X28 3CK2B 2025 44',O" X26'4" HUD a a s N Feature Option Quantity Page:1 of6 Ext. Price WARRANTY CHANGEFEES OTHER OTHER AXLE WINDZONE WINDZONE ROOFINS ROOFLOAD ROOFPITCH FLOORINS WALLINS SWALLHT Program & Fees EXTWARRANry EXTWARMNTYTHRU YR7-ASSURANT OPOOIOOB PRODUCTION CHANGES NOTE: ADD PATTO DOOR @ MASTER BEDROOM NOTE: MOVE WNDOW TO MASTER BEDROOM ENDWALL MOVE LRMNDOWS & FTR. DOOR MOVE MASTER BEDROOM WALL (SEE PRtNl) Packages OPOO2O64 DW PD 2T&TTIO UPTO6OFT T&T THROUGHOUT -VOG CLOSEIS TRIM UPGRADED oP001296 MODEL# 8862 J oP000305 10 AXLES: I BRAKE / 6 BLANK oP001599 oP001602 oP000386 oP001232 oP000036 oP000313 oP000436 oP000033 Gonstruction SKYLINE CAD INK # 150 150.00 1,845.00 Slandard 540.00 Standard 705.00 1,980.00 Standard 1 ,1 90.00 1,800.00 Standard IDLER AXLE W/ TIRES: REC-EXTRA HUD WIND ZONE I HUD ENERGY ZONE 3 R-38 CEILING IPO R-19: DW 40# ROOF LOAD PER RF: 2BW HUD 3/12 ROOF PTTCH R-22 FLR INSULATION 24128..DW 2XG R-19 : DW 28 8'SIDEWALL STD 2 1 1 1 44 Champion is a registered trademark of Champion Home Builders, lnc. HUD LABEL NO#: 'This manufactured home is designed to comply with the Federal Manufactured Home Construction and Salety Standards in force at the lime of manufacture." OR 'This manufactured home has been substantially completed in the accordance with the approved design and been inspected (ex€pt for the components specifi€lly identified in the instructions for completion on-sile) accordance with the Federal Manufactured Homes Construction and Safety Standards and the requirements of the Department of Housing and Urban Development (HUD) in effect at that date of manufacture." "This manufactured home lS designed to accommodate the additional loads imposed by the attachment of an attached accessory building orstructure in accordance with the manufacturer installation instructions. The additional loads are in accordance wilh the design load(s) identifiedon this Data Plate." OR "This manufactured home lS NOT designed to accommodate the additional loads imposed by the attachment of an attached accessory buildingor structure in accordance with the manufacturer installation instructions." DATE OF MFG DESIGNAPPROVED BY: PFS MANUFACTURER MODELNUMBER 1 ITEMS COMFORT HEATING This manufactured home has been thermally insulated to conform with the requirements of the federal manufactured home construction and safety standards for all lo€tions within Uo Value Zone 3 Heating equipment manufacturer and model (see list at left). The above heating equipment has the capacity to maintain an average 70'F temperature in this home at outdoortemperatures of F To maximize furnace operating economy, and to conserye energy, it is recommended that this home be installed where the outdoor winter design temperature (97 %%) is not higher than degrees Fahrenheit. COMFORT COOLING Air conditioner proMded at factory (Altemate l) Air conditioner manufaclurer and model (see list at left), Certified capacity 0 BTU/hour in accordance with the appropriate Air Conditioning and Refrigeration lnstitute Standards. The central air conditioning system provided in this home has been sized assuring an orientation of the front (hitch end) of the home facing . On this basis the system is designed to maintain an indoor temperature of 75'F when outdoor temperatures are 0 F dry bulb and 0 F wet bulb. The temperature to which this home can be cooled will change depending upon the amount of exposure of the windows of this home to the sun's radiant heat. Therefore,the home's heat gains will vary dependent upon its orientation to the sun and any permanent shading provided. lnfomation mnceming the calculation of cooling loads at various locations, windows exposures and shading are provided in The 1997 ASHRAE Handbook of Funda- mentals, lnch-Pound Edition. Air conditioner not provided at factory (Altemate ll) The air distribution system of this home is suitable for the installation of central air conditioning. The supply air disiribution system installed in this home is sized for a manufacturedhomecentralairconditioningsystemolupto0 BTU/hrratedcapacitywhich are certified in accordance with the appropriate Air Conditioning and Refrigeration lnstitute Standards, when the air circulators ol such air conditioners are rated at 0.3 inch water column static pressure or greater for the cooling air delivered to the manufactured home supply air duct system. lnfomation necessary to calculate cooling loads at various locations and orientations is provided in the special cornfort cooling information provided wlth this manufactured home. Air conditioning not rccommended (Altemate lll) The air distribution system of this home has not been designed in anticipation of its use with cenlral air conditioning syslem. INFORMATION PROVIDED BY THE MANUFACTIJRER NECESSARY TO CALCULATE SENSIBLE HEAT GAIN Walls(without windows and doors) ilUi' = 0 000 Ceilings and Roofs of Light Color nU( = 0 000 Ceilings and Roofs of Dark Color ilU' = 0.000 Floor "U" = 0.000 Air Ducls in Floor ,'U" = 0.000 Air Ducts in Ceiling "Un = 0.000 Air Ducts installed outside the home nun = 0.000 The following are the ducts areas in lhis home: Air ducts in Floor o sq' Ft Air ducts in Ceiling 0 Sq. Ft Air ducts oulside the home 0 Sq' Ft To detemine the required capacity of equipment to cool a home efficiently and economically a cooling load(heatgain)€lculationisrequired. Thecoolingloadisdependentontheorientation,locationand the structure of the home. Central air conditioners operate most efficiently and provide the greatest comtortwhentheircapacitycloselyapproximatesthecalculatedcoolingload. Eachhome'saircondi- tioner should be sized in accordance with The 1997 Handbook of Fundamentals, lnch-Pound Edition, once the location and orientation are known. Uo Value Zone Map for Manufaclured Housing zdE2 MFG. Champion Home Builders, lnc. 315 West Skyline Road ARKANSAS CITY, KS,67005 UNIT SER. # MODEL#: 233-00P-H-A01 29654B LH 2 8862 { e HOME CONSTRUCTION Zonel tl This home has not been higher wind pressure and anchoring provisions required for ocean/coastal areas and should not be localed within 1 500' of the coastline in Wind Zones ll and lll, unless the home and its anchoring and foundation system have been designed for the increased requirements specifled for Exposure D in ANSYASCE 7-88. This home has[ has been equipped with storm shutters or other protective coverings for windows and exterior door openings.homes designed to be located in Wind Zones ll and lll, which have not been provided with shutters or equivalent covering devices, it is strongly recommended that the home be made ready to be equipped with these devices in accordance with the method recommended in manufacturers printed instructions. NH ZONEI zdE I zdE I Zonel Zone ll Zone lll lryPlC t) Structural Wind Zone If checked; ANCHOR STRAPS MUST BE INSTALLED TO SECOND BEAM PER INSTALLATION ADDENDUIV Nqu MIDDLE f-lzon" lll flExposure D $\.s f-'lzon. L____.1tt_I ZoneL,l I x pon" W HEATING & COOLING OESIGN MAP SOUTH 20 PSF MIDDLE 30 PSF NORTH 40 PSF OTHER {u. SOUIH The manufacturer certifies this home is compliant with the Title Vl, Toxic Substances Control Act. See Packet for Addendums to the lnstallation Manual. X X X UI xs ok XNOTE: Hawaii, Puedo Ri6 andvlrgin lslands are Soulh Zone STRUCTURAL ROOF DESIGN MAP 1 - 0.116 2 - 0.096 3 - 0.079