October 30,2024 Project No. C1916
David Jones
d richmond iones@gmail.com
Su bsurhce lnvestigation and Onsite Wastewater Treatment System Design
3-Bedroom Residence + Future 2-Bedroom ADU
6533 CR 214
Garfield County, Colorado
David,
CBO lnc. perfonned a subsurfae,e investigation and completed an onsite wastewater treatment system
(OWTS) design for the subject property. The 1.559-acre properly is located outside of New Castle, in an
area where OWTSs and wells are neoessary.
Legal Description: Section: 4 Township: 6 Range: 91 TR OF LAND lN LOT 4 1.56 ACRES
Parcel lD: 2181-042-00-013
SITE CONDITIONS
The property is cunently developed with a 3-bedroom residence, originally constructed in 1962, that is
being renovated. No doc,unentation was available from Garfield County Land Explorer on the existing
OWTS serving the residence. A detached 2-bedroom accessory dwelling unit (ADU) is also proposed.
The existing OWTS will be propedy abandoned. The proposed design willaccommodate both the
existing residence and the proposed ADU,
The residences will be served by a private well on flre proper$. The well is located to the north of the
existing and proposed residence. An additionalwell is located on the property to the west, nearthe
shared property line. Both wells are located greater than 50-bet from the proposed septic tank and
greater than 1O0-feet from the proposed soil treatment area (STA).
The proposed soiltreatment area (STA) location has an approximate five perent slope to the south. The
proposed area is vegetated with native gmsses and some trees that may need to be removed.
There is an existing driveway off the county road that runs to the north in the southwest portion of the
property. This driveway will be abandoned. The soils in the area of the driveway are unlikely to have
been compacted because soils contain minimalclay.
There should be no haffic or staging of material over the future STA site to avoid compaction of soils
priorto construction of the STA.
Page2
SUBSURFACE
The subsurface was investigated on ftober 16, 2024 by digging two soil profile test pit excavations (Test
Pits), A visual and tactile soil analysiswas completed by Carla Ostberg atthe time of excavation.l
The materials encountered in Test Pit#1 consisted of light brown sandy loam to a maximum depth
explored of 7.5-bet. No bedrock or groundwater was en@untered.
The materials encountered in Test Pit #2 were consistent wi$r those encountered in Test Pit #1 . Test Pit #2
was excavated to a maximum depth explored of 7.S-feet. No bedrock or groundwater was encountered.
A sample of the soil was taken from Test Pit #1 at 4-feet below grade. Soil structure grade was
moderate. The soilformed a balland a weak ribbon less $an 1-inch in length before breaking. Soil
structure shape was blocky and consisten@ was friable. Soiltexture was more gritty than smooth.
We have researched soils in the area through USGS Web Soil Survey. The report is enclosed. The area of
the proposed STA is identified by map unit symbol 51. The map unit name is Onley loam, 3 to 6% slopes.
The soil is onsistent with Soil Type 2, Sandy Loam, with moderate structure grade. A long-term
acceptance rate (LTAR) of 0.6 gallons per square foot will be used to design the STA.
lf soils in the area of the former driveuay appear compacted (dense), this office must be
contacted for mitigation measurcs which would include removing the compacted soils and importing
approved sand filter material.
Test Pit#1 Backfill
' Carla Ostberg holds a Certifcate of Attendance and Examination from the CPOWVisual and Tactile
Evaluation of Soils Training.
Page 3
Profile
Sieved s€lmple Ribbon less than 1-inch
Test Pit#1
Page 4
View of Test Pits and Test Pit#2
DESIGN SPECIFICATIONS
Any existing OWTS components serving the existing residence must be properly abandoned. The
existing septic tank should be removed or pumped and ttre top, bottom, and sides crushed and any
remaining void filled with onsite materials. The existing STA will be abandoned in place or if a
component with any type of void is discovered, it should be pumped and filled, as needed.
Desiqn Calculations:
AverageDesignFlow=(T5GPDx2people/bedroomx3Bedrooms)+ZSGpDx2people/bedroomx2
Bedrooms) = 750 GPD
LTAR = 0.6 GPD/SF
750 GPD / 0.6 GPD/SF = 1250 sF x 1.0 (gravity trenches) x 0.7 (chambers; = g7s sF
875 SF / 12 SF/chamber = min. 73 'Quick 4' Infiltratofl$ chambers
The OWTS design is based on 3-bedrooms in llrc residence and 2-bedrooms ln the ADU. An average
daily wastewater flow of 750 GPD will be used.
Page 5
For the purposes of this OWTS design, Benchmark Elevation has been established as 100' (Finished
Floor of-existing 3-bedroom residence). CBO Inc. should be notified of any discrepancies or problems
with grade etevations of proposed components during installation of the OWTS.
*Elevations are based upon standard installation practices. Component elevations may change during
installation due to site conditions. Minimum grade refers to piping between components.
The 4-inch SDR-35 sewer line exiting the residence must have a double-sweep clean out and a minimum
2o/o grade to the septic tank. The sewer line serving the future ADU will be installed at the time of
construction of the ADU-
The system installation must include a 1S0O-gallon, two-compartment lnfiltrator@ poly septic tank with an
Orenco@ Biotube effluent filter on the outlet tee. Risers must bring the manhole lids to grade for access.
lf more than one riser is added to the septic tank, an extension handle must be installed on the effluent
filter.
Effluent will gravity flow to a distribution box, and then to six gravelless chamber trenches. The
distribution box must be accessible from grade and must have flow equalizers, or similar product,
installed on each outlet pipe in the distribution box to assure equal flow to each trench.
Each trench will consist of 13 'Quick 4' Standard Plus lnfiltrator@ chambers for a total of 78 chambers
and 936 square feet of infiltrative area. There must be at least 4-feet of undisturbed soil between each
trench. lnspection ports must be installed atthe beginning and end of each trench. Ports may be cut to
grade and placed in sprinkler boxes for access.
COMPONENT SPECIFICATIONS
The component manufacturers are typical of applications used by contractors and e19!ne9rs in this area-
GBO lnc. must approve alternative components prior to installation of the OWTS. Requests must
be submitted, in writing, to our office for approval prior to installation. Component technical data
sheets are available upon request.
Minimum ElevationOWTS Gomponent
Approximate horizontal
min.3.75" fall
distance 15'l min. 2o/otall IPrimary Tank lnlet lnvert
Approximate horizontral distance 14' I min. 1o/o fall I
min. 1.75" fall
Distribution Box
Approximate horizontal distane 23' to fu rthest
trench I min. 1o/o fall to STA / min. 2.875" tall
lnfiltrative Surface
COMPONENT MANUFACTURER MODEL NO.I COMMENTS
Septic Tank lnfiltratoflD M-1530-2CP
septic
Effluent Filter Oreno@ " diarneter full size filter
Tank Risers and Lids Orenco@ IDoubl+walled PVC Risers and
Itios (z+" diameter)
I
Distribution tsox Polylok lDistribution box, risers, lid, flow
lequalizers (6)
Chambers lnfiltratoflD -Quick 4' Plus Standard
Chamber lZ8'Ouick
4'chambers
Page6
Construction must be according to the jurisdiction's adopted On-Site Wastewater Treatment System
Regulations, the OWTS Permit, and this design.
PERMIT APPLICATION INSTRUCTIONS
An OWTS PermitApplication must be submitted to Garfield County Environmental Health Department.
https://www.qarfield-countv.com/environmental-health/filesqcco/sites/16/OWTS-Application-Complete-
PacketDec.-20't9.pdf. lf the OWTS PermitApplication willbe submifted with a Building Permit
Application, it should be submitted directly to Garfield County Building Department.
All questions regarding permit submission can be directed to Garfield County Environmental Health
Department, 970-945-6614 x81 50.
INSTALTATION CONTRACTOR
CBO lnc. expects that the installer be experienced and qualified to perform the scope of work outlined in this
design. The installer must review this design thoroughly and coordinate with our offie in advance of
installation. Any additionalconditions in this design or county permit must be completed and documented
priorto finalapproval of the OWTS installation. Communication between the installerand this office is
expected throughout the installation.
INSTALLATION OBSERVATIONS
CBO lnc. must view the OWTS during construction. The OWTS observation should be performed before
backfill, after placement of OWTS components. Septic tanks, distribution devices, pumps, dosing
siphons, and other plumbing, as applicable, must also be observed. CBO lnc. shouH be notified 48 houri
in advance to observe the installation.
ln an effort to improve the accuracy of the record drawing, we request that the installer provide a
sketeh of the installation, including path of the sewer linesn water line installation (ii applicable),
septic tank location, STA location, and measurements from building comens or anothli fixeO
gbigcts on the property. This sketch is most easily provided on Sheet tnB.O ottne OWTS Design
Packet. Photographs of the installation and final cover are also requested to supplement our installation
documentation.
REVEGETATION REQUIREMENTS
An adequate layer of good quality topsoil capable of supporting revegetation shall be placed over the entire
disturbed area of the OWTS installation. A mixture of native grass seed that has good soil stabilizing
characteristics (but without taproots), provides a maximum transpiration rate, and competes well w1fi
successional species. No trees or shrubs, or any vegetation requiring regular inigation shali be placed over
the STA. Until vegetation is reestablished, erosion and sediment control measures shall be implemented
and maintained on site. The owner of the OWTS shall be responsible for maintaining proper vegetation
@ver.
OPERATION INFORMATION AND MAINTENANCE
The property owner shall be responsible for the operation and maintenance of each OWTS seruieing theproperty. The property owner is responsible for maintaining seruice contracts for manufactured Jnits,
alternating STAs, and any other components needing maintenance.
Geo-fabrics or plastics should not be used over the STA. No heavy equipment, machinery, or materials
should be placed on the backfilled STA. Machines with tracks (not wheels) should be used during
construction of the STA for better weight distribution. Livestock should not graze on the STA. plumbin!
PageT
fixtures should be checked to ensure that no additionalwater is being discharged to OWTS. For example, a
running toilet or leaky faucet can discharge hundreds of gallons of water a day and harm a STA.
lf an effluent filter or screen has been installed in the OWTS, we re@mmend this filter or screen be cleaned
annually, oras needed. lf the OWTS consists of a pressurized pump system, we re@mmend the laterals be
flushed annually, or as needed.
The homeowner should pump the septic tank every two years, or as needed gauged by measurement of
solids in the tank. Garbage disposal use should be minimized, and non-biodegradable materials should not
be placed into the OWTS. Grease should not be placed in household dnains. Loading ftom a water softener
should not be discharged into the OWTS. No hazardous wastes should be directed into the OWTS.
Mechanical room drains should not discharge into the OWTS. The OWTS is engineered for domestic waste
only.
ADD]TIONAL CONSTRUCTION NOTES
lf design includes a pump, weep holes must be installed to allow pump lines to drain to minimize risk of
freezing. The pump shall have an audible and visual alarm notification in the event of excessively high-
water conditions and shall be connected to a control breaker separate from the high-water alarm breaker
and from any other control system circuits. The pump system shall have a switch so the pump can be
manually operated.
Excavation equipment must not drive in the excavation of the STA due to the potentialto compact soil.
Extensions should be placed on all septic tank components to allow access to them from existing grade.
Backfill over the STA must be uniform and granular with no material greater than minus 3-inch.
LIMITS:
The design is based on information submifted. lf soil conditions encountered are different from conditions
described in report, CBO lnc. should be notified. AIIOWTS construction must be according to the county
regulations. Requirements not specified in this report must follow applicable county regulations. The
contractor should have documented and demonstrated knowledge of the requirements and regulations of
the county in which they are working. Licensing of Systems Contractors may be required by county
regulation.
Please call with questions.
Sincerely,
CBO lnc.
(a,,[a C*hu,g
Carla Ostberg, MPH, REHS
Sheet 1 0F 4
w1 .0
Date: 1Ol3Ol2O24
Designed by: CBO
Drawn by: DD
6
c
c]v
m€STA
*
I
:{*:
a
i' .J':
I eir
TP2
TP1
a
N
swz&r 2w .olillt tnw? ttnogP
660f c?ailry 80/2 afJt0" 6 ?&rer riur,,ymuB,gw SCALE: 1 = 50'=0"n
It
b
fliEznr afiD 22vt tnwT tiRoET860' COAtZrSd/2 2t140" 6 PtleE 7/Utrtymdn,ga?
35,75
.m.OA D t:rArrm,r3, trAt',,rjEntnS
8699 6?An r 80/2 2fJ thetO" A nE/eE 7/UAETma?,gz?
I
a
2-BEDROOM
ADU
3.BEDROOM
RESIDENCE
ROPERry LINE
-COUNTY ROAD 214
I
THE LOCATION OF PROPOSED IMPROVEMENTS SHOWN ARE
NOT THE RESULT OF A PROPERry SURVEY. TXC IOCNTIOTTS
ARE APPROXIMATE. IT IS THE HOMEOWNERS'DUryTO
ENSURE ALL CONSTRUCTION AND IMPROVEMENT LOCATIONS
ARE ACCURATE. PROPERry LINES AND SETBACK DISTANCES
SHOULD BE CONFIRMED PRIOR TO EXCAVATION. SCALED
FOR PRINTING ON 11" X 17" PAPER.
/aSlTE PLAN CALL 811 FOR UTILITY
LOCATES\-7 1'- 5O' - 0-
Roaring Fork Land & Home, lnc.
6533 CR 214
Garfield County, Colorado
Project Number: C1916
oa
I
.:1.
;.a
.,:::
645/
.f'
Water
dtP
f
fuicg,
A@
,&oru
throttdt
ahJcctprqtty to
thc
thcNttl,ot
adJotthtgptcd
Rac. na lrJOil
gg,-l
Uffilty
tutc
t+F
*
Pagc
toRcfs
Wcllw
2of2
DRAWINGS MUST BE USED IN
CONJUNCTION WITH DESIGN
LETTER DATED 1OI3OI2O24
oE Dr
U J'1.E2)
'r
\:.
xgg&98'tn&
E
t
(N
a
lau aEw5i657.Ji6'
Fnd. Alumts
vldc
Pbc
l
o
(
33 Four Wheel Drive Road
Carbondale, Colorado 81 623
Phone 970.309.5259
carla@allserviceseptic.com
Sheet 2OF 4
w2.0Date: 1013012024
Designed by: CBO
Drawn by: DD
'l-. j l
-l- .l :'
t-l I
trtritr:Tffi
SCALE: 1" = 20'-0"
N
z
:t
BM1
3-BEDROOM
RESIDENCE
oo
!E
,.#l
o
RE
2-BEDROOM
ADU
-i::
-rt'i'i
.5
*e
d5
Roaring Fork Land & Home, lnc.
6533 CR 214
Garfield County, Colorado
Project Number: C1916
1
(t!
-f '{1-l
L -' ,
/rllAJ
:"'.- i;
o
s
r\
4" DIA SDR.35 SEWER PIPE WITH CLEANOUT
MtN 2% FALL TO TANK\l ' I \
1 sOO.GALLON, TWO.COM PARTMENT
SEPTIC TANK WITH EFFLUENT SCREEN
4'DIA SDR.35 SEWER LINE TO D.BOX
(1% FALL TO D-BOX)
10'MlN
!
@a'
DISTRIBUTION BOX
WITH ACCESS AT GRADE
LINE TP
CorI
Cqroge
Gra,
req,B*
B
|{l
IIbF
:
: .1... ' ..r
e@
oQ b
TP2
ov
m€
oQ
I Tl2s / rre/s
Ir#t,rfi!*
.QUICK.4'CHAMBER
6 TRENCHES WITH 1
TRENCHES.
3 CHAMBERS PER TRENCH
CHAMBERS AND 936 SF.
Trlsr FORrfl-p A TOTAL OF 78 =bTI
.t 4" DIA SDR.35 DISTRIBUTION
LINE TO EACH TRENCH
(MrN. 1% FALL TO TRENCH)
4" DIA SDR-35 INSPECTION
PORT AT BEGINNING AND END *
OF EACH TRENCH
E \
CBO lnc.
129 Cains Lane
Carbondale, Colorado 81623
Phone 970.309.5259
carla.ostberg@gmail.com
IIIIIIIIIIII'
IIIIIIITIIIIIIIIIIITIIIIII
IIilTIIIIITTIITIIIIIIIII!II
DISTRIBUTION BOX WITH ACCESS AT GRADE
GRAVELLESS'QU|CK4' CHAMBER(a'x 3')
4" DIA SDR-35 EFFLUENT PIPE FROM SEPTIC TANK
SLIP.ON PVC
DO NOT GLUE
INSULATED
13 CHAMBERS PER TRENCH TRACER WIRE FINISHED GMDE
4" DIA SDR-35 INSPECTION PORT AT BEGINNING
AND END OF EACH TRENCH
4 INFILTRATOR
END PLATE
4'DIA SDR-35
SEWER LINE
TO TANK TO HOUSE
-
PIPES PLACED IN TOP PORT
CHAMBER END PLATES
4' DIA SDR-35 DISTRIBUTION LINE TO EACH
TRENCH
(MtN. 1% SLOPE TO TRENCH)
SMALL VALVE COVER
BOX OR IRRIGATION
VALVE BOX AT GRADE BOXAND COVER BROUGHTTO GRADE
CAP OR THREADED CONCRETE LID
" DIA SDR-35 CLEANOUT ASSEMBLY
INSPECTION
PORT
FINSHED GRADE
4 max
L
COMPACT
SOIL 2'minl BASE TO SUPPORT
BOX
4' PVC PIPE CUT TO
FIT
-
4'min USE HOLE SAW TO
CUT THRUTOPOFLIMIT BAFFLE OR
ANGLED PIPE
TO BE USED
EXCAVATION END PLATE
SCARIFY
GMVELLESS'QUICK.4'
CHAMBER (4'x 3')
AT INLET
ON
^,\
OUTLETS
oooo
CBO lnc.
129 Cains Lane
Carbondale, Colorado 81 623
Phone 970.309.5259
carla.ostberg@gmail.comst.:I.'t. t(' ( ;( )r-s('r.a'I N( ;
sl'"w..ffi
6533 CR 214
Garfield County, Colorado
Project Number: C1916
Roaring Fork Land & Home, lnc.10t30t2024
ned by: CBO
by: DD
w3.0
Sheet 3 0F 4
DESIGN
3.BEDROOM RESIDENCE + FUTURE 2.BEDROOM ADU
(75 GPD x 2 PERSONS/BEDROOM x 5 BEDROOMS)
WASTEWATER FLOW = 750 GPD
USE 15OO GALLON, TWO.COMPARTMENT SEPTIC TANK
SOIL TREATMENT AREA (STA):
LONG TERM ACCEPTANCE RATE (LTAR) = 0.6 GAU SF
CALCULATED STA = Q/LTAR = 750 / 0.6 = 1250 SF
1250 SF x 1 .0 (GRAVITY TRENCHES) X 0.7 (CHAMBERS) = 875 SF / 12 SF/CHABMER = MlN. 73
CHAMBERS
SOIL PROFILE TEST PIT NO. 1 SOIL PROFILE TEST PIT NO.2
0
LIGHT BROWN SANDY LOAM LIGHT BROWN SANDY LOAM
LEGEND
fS topsoil
m sandy
loam
NO GROUNDWATER OR BEDROCK ENCOUNTERED
DURING EXCAVATION
FINISHED GRADE
2
24'MlN.
3'MlN.
F
IIJttl
lJ-
I
IF
o_[!o
3
4
5
6
7
I
I
10
4'DIA SDR-35 SEWER LINE
(MtN 2% SLOPE TO TANK,
MrN. 1% TO STA)
SCREENED ROCK
OR SAND FOR
BEDDING
8'MIN
w4.0
OWTS COMPONENTS AND
PHYSICAL FEATURES
MINIMUM REQUIRED
SETBACK
APPROXIMATE PROPOSED
SETBACK
HOUSE TO SEPTIC TANK 5'8'
SEPTIC TANK TO WELL 50'221',
SEPTIC TANK TO WATER COURSE 50'N/A
STATO HOUSE 20'29',
STA TO WELL 1 00'245',
STATO WATER COURSE 50'N/A
BACKFILL
CBO lnc,
129 Cains Lane
Carbondale, Colorado 81 623
Phone 970.309.5259
carla.ostberg@g mail.com
6533 CR 214
Garfield County, Colorado
Project Number: C1916
Roaring Fork Land & Home, lnc.Date: '1013012024
Designed by: CBO
Drawn by: DD Sheet 4 0F 4
Legend6533 CR 214
9125124,10:46AM qPublic.net - Garfield County, CO - Property Record Card: R013090
sf
+- ONE 112.0 sf ?
t\Jq bN
28'
28'
owB
s60.0 f
-o
4 t2'
kAI
8'
or
ONE 488.0 sf 36'
I he Garfreld Cou nty Assessor's Office rnakes every effort to produce the n'lost accurate
information possible. No warranties, expressed or i:nplied are provicled for the data herein, its
use or interpretation. Data is subject to constant change aild its accuracy and completeness
cannot be guaranteecl.
I Use[ Privacv Pellc,l I GDPRPTivaE Notic_e
Laqt Oata u ple3d:_ilZfl 294,1291:08AM
Contact Us Developed by
Q sc'1y"e.gg5
9t25t24,10:46AM qPublic.net - Garfield County, CO - Properly Record Card: R013090
Actual Values
TaxYear xn4 2{Jf23 m2:t zutt mtn
AstualValue 9411,270.00 *471270.fi t291510.00 t291,510.00 t267,750ffi
Assessed Values
TaxYear 2024 xn!xrn xm minJ
AssessedValue
Tax History
TaxYear
$27,5s0.00 $27'550.O0
m23
$20,260.00
xnz
$20,8,{Om
m2t
$19,11{}00
xrzJ
Taxes Billed $1,4{)820
Click here to view the tax information for this oarcel on the Garfield CounW Treasurer's website.
Transfers
Sale Date Deed
6t30t2023 SPECIALWARRANTY DEED
Reception Number Book- Pace
$1,118.20 $r,297-96 $!,o74.e
SalePrie
?47286 $40o,mo
u1ano22 INCLUSION 975077 $o
LO/tO|7999 QUITCLAIMDEED 554029 LLs6-342 $o
70t8tt999 EASEMENT 554026 tts6-377 $o
6128/1997 POWEROFATTORNEY 554028 1156-381 $o
3126/tee3 WARRANTYOEED o858{181 $o
u12/1986 WARRANryDEED
9/T511980 WARRANryDEED
Propefi Related Public Documents
ellck here tgtyleqPIepclLy &elated Public Documents
Photos
Sketches
hftps://qpublic.schneidercorp.com/Application.aspx?ApplD=1o38&LayerlD=22381&PageTypelD=.4&PagelD=gzt47&Q=1910135766&KeyValue=R013090 213
9125l/24,10:46AM
Garfield County, CO
Summary
Amrnt
Parcel
ProDerV
Address
leeal Descrlpdon
Acr€s
tandSqFt
TaxArea
Mllllsy
9rbdMsim
qPublic.net - Garfield Gounty, CO - Property Record Gard: R013090
ffiRO13)90
2181042mO13
6533 214 COUNTY RD NEWCASTLE CO 41647
Section:4Township: 5 Ran8p: 9ITROFLAND lN LOT4 1.56
ACRES
L559
o
144
511150
Map
ViewMao
Owner
ROARING FORK LAND &HOME INC
6809COUNryROAD214
NEW CASTLE CO 81647
Land
UnitType SINGLE FAM.RES.-LAND - 1112 (RESIDENTIAI PROPERTY)
SquareFeet O
Buildlngs
Building#
Unlts
BuildingType
Abstract Cod€s/ (Propefi Typel
Arcftltectural Style
Storles
Frerp
Actual Year Built
BenentArea
GrogslhrhgArea
Total Hcated SqFt
Bedrooms
Baths
HeatingFuel
HeatlngType
AirGodiffonlng
RoofType
RoofCd€r
t
t
SFR
SINGLE FAM.RE5.IMPROVEMIS.1212 (RESIDENTIAL PROPERTY)
1-5TRY/BSM
7
WOODFRAME
L962
560
Lt6oI,tfi
3
L
GAS
FORCEDAIR
NONE
GABLE
COMPSHNGL
i'l
1,'I-li:
(',
ci
,,1
l-)
hr
-Ll
i--"i- t.
(:-,'t
Irr,,tr lr Vitllr:y fili
1 rEtil':'}\7rt{!1 :t?*A i{nl{iiJ trlicl
tg$.['l!U
t{ffiltr-dltr,;inrn(..
l
&
f tii,lil:ilx!,
i'.{fi{r[..{PI*]iT'H
1J'illyi t'
,li lilllr (llrli 1 i lrlil
GDqPublic.net'" Garfi eld County, CO
Account RO13O9O
Number
Parcel Number 2L81O42OOOL3
Acres 2
LandSqFt O
TaxArea 144
Mill Levy 51.1150
6533274COUNWRD
NEWCASTLE
ROARING FORK LAND & HOME
lNc
6809 COUNTY ROAD 214
NEW CASTLE CO 8T647
Physical
Address
Owner
Address
TotalActual
Value
Overview
Legend
f Parcels
Roads
Parcel/Account
Numbers
OrnerName
i I lakes&Rivers
- CountyBoundary
Line
$4lt27g last2Sales
Date Price
6t30t2o2s $4OO,o0onla $
81647
Datecreatd:9/25/2O24
Last Data Uploaded : 9 I 25 I 2O24 2:31:OB AM
Develonea uvlS SCHNStDER
GEOSPATIAI
GS **:::-:j:3;:-"Map Viewer
; Well Constructed
e Final Permit
si Ground Water
x Geophysical Log
c Confluence Point
Source Water Route Framewo
Lj County
Superfund Sites
Legend
a
r- l
Location
Notes
292 0 146 292 Feet
I
1: 1,754 {}
This ptoduct is for informational pul.poses and may not have been prepared for, or be suitable for legal,
engineeing, or suNeying purposes. Users of this information should review or consult the pimary data and
information sources to asceftain the usability of the information.
Date Prepared: 1013112024 9:06:00 AM
Map Unit Description: Olney loam, 3 to 6 percent slopes-Rifle Area, Colorado, parts of
Garfield and Mesa Counties
Hydic soil nfing No
Data Source lnformation
Soil Survey Area: Rifle Area, Colorado, Parts of Garfield and Mesa Counties
Survey Area Data: Version 17, Aug 29,2024
TJSDA
-
Nafural Resources
Consewatort Ssrvice
Web Soil Survey
Nalional Cooperative Soil Survey
10130t2024
Page 2 of 2
Map Unit Description: Olney loam, 3 to 6 percent slopes-Rifle Area, Colorado, Parts of
Garfield and Mesa Counties
Rifle Area, Colorado, Parts of Garfield and Mesa
Counties
S0-Olney loam, 3 to 6 percent slopes
Map Unit Sefting
National map unit symbol: jnyl
Elevation: 5,000 to 6,500 feet
Farmland classification; Prime farmland if irrigated
Map Unit Composition
Olney and similar soils: 85 percent
Estimates are based on obseruations, descriptions, and transects of
the mapunit.
Description of Olney
Sefting
Landform: Alluvial fans, valley sides
Down-slope shape: Linear, convex
Across-s/ope shape: Linear, convex
Parent mateial: Alluvium derived from sandstone and shale
Typical profile
Hl - 0 to 12 inches.' loam
H2 - 12 to 33 inches: sandy clay loam
H3 - 33 to 43 inches: gravelly sandy clay loam
H4 - 43 to 60 inches: very gravelly sandy loam
Properties and qualities
S/ope:3 to 6 percent
Depth to restictive feature: More than 80 inches
Drainage class; Welt drained
Runoff class: Medium
Capacity of the most limiting layer to transmit water
(Ksat): Moderately high to high (0.60 to 2.00 in/hr)
Depth to water table: More than 80 inches
Frequency of flooding: None
Frequency of ponding: None
Calcium carbonate, maximum content: 15 percent
Maximum salinity: Nonsaline to very slightly saline (0.0 to 2.0
mmhos/cm)
Available water supply, 0 to 60 inches: Moderate (about 7.6
inches)
lnterpretive groups
Land capability classification (inigated): 3e
Land capabil ittl cl assification (no n i nig ated) : 3c
Hydrologic Soil Group: B
Ecologicalsrte: R048AY306UT - Upland Loam (\Afioming Big
Sagebrush)
USDA
-
Natural Resources
Gonservation Service
Web Soil Survey
National Cooperative Soil Survey
10t30t2024
Pagel oI2
Soil Map-Rifle Area, Golorado, Parts of Garfeld and Mesa Counties
Map Unit Legend
iiap unit symbot Itap Unlt Namo AOrcslnA0l PercgntofAOl
50 Olney loam, 3 to 6 percent
slopes
0.5 5.6%
5'l Olney loam, 6 to 12 percent
slopes
8.6 94.4o/o
Totals for Area of lnterest 9.1 100.0%
USDA
-
l{atural Resources
Consewaffon Service
Wbb Soil Survey
National Cooperalive Soil Survey
'loB0no24
Page 3 of3
USDA
=-
Natural Resources
Conservation Service
Soil Map-Rifle Area, Colorado, Parts of Garfield and Mesa Counties
Web Soil Survey
National Cooperative Soil Survey
10t30t2024
Page 2 of 3
MAP LEGEND MAP INFORMATION
The soil surveys that comprise your AOI were mapped at
1:24,000.
Warning: Soil Map may not be valid at this scale,
Enlargement of maps beyond the scale of mapping can cause
misunderstanding of the detail of mapping and accuracy of soil
line placement. The maps do not show the small areas of
contrasting soils that could have been shown at a more detailed
scale.
Please rely on the bar scale on each map sheet for map
measurements.
Source ofMap: Natural Resources Conservation Service
Web Soil Survey URL:
Coordinate System: Web Mercator (EPSG;3857)
Maps from the Web Soil Survey are based on the Web Mercator
projection, wttich preserves direction and shape but distorts
distance and area. A projection that preserves area, such as the
Albers equal-area conic projection, should be used if more
accurate calculations of distance or area are required,
This product is generated from the USDA-NRCS certified data as
of the version date(s) listed below
Soil Survey Area: Rifle Area, Colorado, Parts of Garfield and
Mesa Counties
SurveyArea Data: Version 17, Aug 29,2024
Soil map units are labeled (as space allows) for map scales
1:50,000 or larger.
Date(s) aerial images were photographed: Aug 25, 2021-Sep
5,2021
The orthophoto or other base map on which the soil lines were
compiled and digitized probably difiers from the background
imagery displayed on these maps. As a result, some minor
shifting of map unit boundaries may be evident.
Area of lnterest (AO1)
Soils
Area of lnterest (AOl)
Soil Map Unit Polygons
g1 Spoil Area
A Stonyspot
dB Very Stony Spot
V Wet Spot
t3 Other
.. Special Line FeatureE
Water Featurcs
Streams and Canals
Transportatlon
1-1.1 Rails
I lnterctate Highways
rry. US Routes
, , Major Roads
Local Roads
Background
I Aerial Photography
p* Soil Map Unit Lines
I Soil Map Unit Points
Speclal Point Features
qg; Blowout
B Borrow Pit
X Clay Spot
O Closed Depression
X Gravel Pit
; Gravelly Spot
O Landfill
A Lava Flow
C3 Marsh or swamp
* Mine or Quarry
O Miscellaneous Water
S Perennial \Ahter
\f Rock Outcrop
+ Saline Spot
:.: Sandy Spot
€p Severely Eroded Spot
* Sinkhole
F Slide or Slip
@ Sodic Spot
B
h
s
R.
Soil Map--Rifle Area, Colorado, Parls of Garfield and Mesa Counties
ztsplo zr9ua 2EEM ziw
Web Soil Survey
Nalional Cooperative Soil Survey
3
lo
s
3qo 33' 42 N
$
39 33'42fN
$
E
R
fr
e
E
e
E
g
fi
B
=b
*
R
z&lg)
Natural Resources
Conservation Service
l@ Scde: 1:1,29) f dnbd on A pdraft (&f x 1f) sH.
l,leEls015x)60s)
0s102mffi
lvlap Holxtin: lthb nae(ebr &rnsodrae; \lES84 EQo tico: LfiM Ane 13I{ VVGS&I
=
3
N
A
10t3012024
Page 1 of3
390 33 3y N
USDA
-
3P 333il
Item #
It-{53G2CP
{53O Gallon Thro Gompartment
lnflltratol@ Poly Tank
61
TANKTOP
HAI'F
CONNNUOUS
EIESTOMETRIC
175.6"TANK
INTERIOR SEAM CLIP
(86)TOP VIEW
ATIGttffiNT
DOWEL(161 TANKBOTTOM
HALF
?4'ACCESSFORT
wnH LocKrNG LrD (3)
tutrffirm.ffi
O uto+erenrsEAu sEcroN DETAIL
OUTLETTEE
TOTALVOL I/sTOTALVOL
SIDE VIEW
SEAMCLIP
r Compliont with CSA ond IAPMO Stondordsr PVC risers ovoilobler Secondory sofety screen ovoiloble with
PVC riser
o Moximum buriol depth is 48"
r Minumum buriol depth is 6"o Tonk is not roted for vehiculor troffic
loodingr Exterior of monhole cover includes the
following worning: "OlnCen DO NOT
ENTER: POISON GASES"
LIFnNGSIRAP
oYHCAT)
END VIEW
ffir,rr$*Ian'
rltrAn$slE
Digging Specs lnvert Dimensions Net
Weight Comp.Totol
16' Long x 7' Wide
43" below inlet
lnlet Outlet Length width Height
44"175.6"6't.7"54.5"501 lbs.1006 sol 503 9ol 1509 9ol
o
o
€oE
o
o
aoet €oso
o
o
flll
II
IIII
lrl
illllllllIrlillltll
iill lrl ltl
iii!lltIil I
I
FIBERGI.A$5
SUPPORT
'f
Wetcr tWerffir
e SYstems
o Pmdudg
InG. oSenl€
(z{9l3ot6zo{ zflffiooru'$7
P.O.Bo(S
Fu: O19) Wrn BHEVldq@-un1
Wrblb: nuw.vallqprcd.ort
Enn[:ffi,
Nomenclatures
tl-in. Biotube FiJter {standard}
FT 04 -I
Blank = l/8" fiitralionP = 1/16" fittralion
Filter diameter (inches)
W = fts Type 3034 outlet pipe
S = fib Schedule,l0 outlet pipe
0ptions:
Elank = no optionsM = flow modulalion plate installedA = float bracket attached
Carfidge heighL 28" and 36" are standard
Housing height 36" and 44" are standard
0ptions:A = Jloatbraclct
FS = 2" oufletorifice
FSO = 2"outletorificeandoverfl0wplate*
Base inlet model
Cartridge height: 14" standard
Housing height 22" standard
Biotube effluent lilter series
8-in. Biotube Fifter (base inletmodel)
FT 08 22- 14 B
Filter diameter (inches)
08 =8"
Blank = 1/8" fifrationP = .l/16" {ilFation
Biotube effluent fllter series
- Also available with c0upling and sleeve as a "kit: FI-0VERFLOWKIT
t[-in. Biotube JL fincludes carridge and housingl
FTJ 04 18
0ptions:
Blank = nooptionsM = flow modulati0n plate installedA = float bracket attached
Caffidge height (inches)
Filter diameter (inches)
W = fitsType3034outletteeS = fils Schedule 40 ouflettee
Blank = 1/8" fittrationP = 1/16" filtration
Junior series
Biotube effluent filter series
&in. Biotube Fiher lnsert (carridse onlyl
Fr i !M ls -n-
For customized
indicates Norttr
oplions (e.9., NC
Carolina regions)
W = fibType3034oudetteeS = fits Schedule 40 outletlee
Cartridge height (inches)
Filter diameter (inches)
Blank = .l/8" liitrationP = 1/16" filtation
lnsert
Biotube effluent filter series
Distributed By:
tl-in. Biotube
Effluent Filter
Extendible PVC handle
Stainless steel set screws
Top seal plate
Air vents
Biotube@ filter cartidge
Solid base
Filter housing
tl-in. Bistube Jr.
Tank wall
Riser
wall
POLYLOK DISTRIBUTION BOX,
RISER$, AND LID
uD€ox 6 & uD€ox8
DAOXSEAL
GI,BYOfiO*8tfirarEA$
16"SIDECUTOT'T
TOACCEPT
FOLYLOKSEAL
NO.3(xr
@@
TEARq'TFOR
4"SDR-350R
scHa)-{0
wOrrosclu-E
UD€OX O'RISER
ROTOfLOW4'
I
6"
t @
uDaox t2'RISER NOTTOScr,IE
FOLYLOCK EOUAl.trER
ry.NOTCH'WEIR
1
S1IIFEF @SE.FLET'E"T|o
RBSFROI'DE
FlTF(nALLf PSED
1 +
20'covER FOR RTSER & D€OX ,vor7t,s/uE
GASKETED SEAL ON
LID & RISER
Wrlrr &Waffir
o Syslems
r Prcduds
Orgl 395€?61 2txFoo m'317
P.O.Bo(95
Fu: O19) gg6\Tt? Bm\Eb' @91u-1
$ftbrlb: wrw.wlblpmd.ort
Enu[:tr Mrrnc.oseryte
Quick4 Plus Standard Chamber Side and End Views
48"
(EFFECTIVE LENGTH)
Quick4 Flus All-in-One 12 Encap Front, Side and End Views
34
r 11-2"
13"
8'INVERT
t
Quick4 Plus All-in-One Periscope
oulcK4 ftus
(3tr SWVIL )
12.7" INVERT
8" INVERT 5.3" INVERTl_
6"
QUICKT nUS
IL-IN-ONE 12
ENDCAP
5"
Quick4 Plus Standard Chamber Specifications
Size(WxLxH)34" x 53" x 12" (86 cm x 135 cm x 31 cm)lnvert Height 0.6u, 5,30, 8,O',, 12,7',
(1.5 cm, 8.4 cm, 18.5 cm, 22.6 cm)Effective Length 48' (1 22 cm)
INFILTRATOR SYSTEMS, INC. STANDAFD LIMITED WARRANTY
(a) The structural integrity of each chamber, end plate, wedge and other accessory manufactured by lnfiltrator ( "Units"), when inslalled and
operated in a leachfield of an onsite septic system in accordance with lnfiltratoas instructions, is warranted to the original purchas€r ("Holdei )
against defective materials and workmanship for one year from the date that the septic permjt is issued for the septic system containing the Units:
provided, however, that il a septic permit is not required by applicable law, the warranty period will begin upon the date that installation of the
septic system commences. To exercise its warranty righls, Holder must notify lnfiltrator in writing al its Corporate Headquarters in Old Saybrook,
Connecticut within fifteen (15) days of the alleged defect. lnfiltrato. will supply roplacement Units for Units determined by lnfiltratol to be covered
by this Limited Warranty. lnliltrator's liability specilically exeludes lhe cost of removal and/or installaiion of the Units.
(b)THE LIMITED WARRANTY AND REMEDIES lN SUBPARAGRAPH (a) ARE EXCLUSIVE. TFIERE ARE NO OTHER WARRANTIES wlTH RESPECT
TO THE UNITS, INCLUDING NO IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOF A PARTICULAR PURPOSE
(c) This Limited Warranty shall be void if any part of the chamber syslem is manufactured by anyone olher than Infiltrator. The Limited Waranty
does not extend to incidental, consoquential, special or indirecl damages. lnfilkator shall not be liable for penalties or liquidated damages,
including loss of production and profits, labor and materials, overhead costs, or other losses or expenses incurred by the Holder or any third pa(y.
Specifically excluded from Limiled Warranty coverage are damage to the Units due to ordinary wear and tear, alteration, accident, misuse, abuse
or neglect of the Units; the Units being subjected to vehicle traffic or other conditions which are not permilted by the installation instructions; failure
to maintain the minimum ground covers set forth in the installation instructions; lhe placement of improper materials into the system containing
the Units; failure of the Units or the septic system due to improper slting or improper sizing, excessive water usage, improper grease disposal,
or improper operation; or any olh€r event not caused by lnfiltrator. This Limited Waranty shall be void if the Holdel fails to comply with all ol the
terms set forth in this Limited Warranly. Further, in no event shall lnfiltrator be responsible tor any loss or damage to the Holder, lhe Units. or any
third party resulting from installation or shipment, or from any product liability claims ol Holder or any third party. For this Limited Waranly to
apply, the Units must be installed in accordance with all sate condilions required by stato and local codes; all other applicable lawsi and lnfiltrator's
installation instructions.
W
I N FI LTRATOR'
systems inc,
6 Business Park Road . P.O, Box 768
Old Saybrook, CT 06475
860.577.7000 . FAX 860,577.7001
800.221.4436
www.inf iltratorsystems,comtd) No
orjginal
representative
Holder,
The above represents the Standard Limited Wa(anty offered by lnfiltrator. A limited number of slates and counties have diflerenl warranty
requirements. Any purchaser of Units should contact lniiltrator's Corporate Headquarters in Old Saybmk, Connecticut, prior to such purchase,
to obtain a copy ot the appiicable warranly. and should carelully read that warranty prior to the purchase of Units.
of lnliltrator has the authority to change or cxtend this Limited Warranty. No warranty applies to any pariy other than thc
THE QUICK4@ PLUS STANDARD CHAMBER
u.s. Palenrs: 4,759,661; 5,0 1 7,041; 5,1 56,488; 5.336,0'l 7; 5,401,1 16; 5,401,459; 5,51 1,903; 5,716,163; 5,588,778: 5,839,844
Canadian Patents: 1,329,959i 2,004,564 Other palents pending.
lnfiltrator, Equalizer, Quick4 and Ouick4 Plus are registered trademarks of lnfiltratol Systems lnc. lnfiltrator is a registered
is a registered trademark in Mexico. Contour Swivel Connection is a trademark of lnfilkator Systems ,nc. @ 2009 lnfiltrator
trademark in France. lnfiltrator Systems lnc
Systems lnc. Printed in U.S.A.PLUS0510r 0tSl-2