Loading...
HomeMy WebLinkAboutBlower Door TestTesting Company: Name:EnergyPro Insulation Address:2892 I -70 B Grand Junction, CO 81501 Phone: 970-623-7327 Technician: Name:Dennis Patterson Credentials: Email:dennispatt27@gmail.com Building Information: Project ID:SCIB llc Address:354 Blue Heron Dr Glenwood Springs , CO 81601 Year Built:2024 Geo-Tag Data:Latitude: Longitude: Timestamp: Customer Information: Name:SCIB LLC Address:0115 Boomerang Rd Suite 5201B Aspen, CO 81611 Phone: 512 673 3867 Email: michael.price@sunriseco.com Measured Leakage:1.80 ACH50 Leakage Target:3.00 ACH50 Compliance with Leakage Target:Pass Test ID:354 Blue Heron Dr (lot 41) Purpose of Test:Envelope (IECC) Measured CFM50:1,086.9 Effective Leakage Area: 59.8 in² Building Volume:36,263.0 ft³Enclosure Surface Area: 3,425.0 ft² Coefficient (C):85.5 Exponent (n): 0.650 (assumed) Test Standard:RESNET 380 One-Point Test Mode: Depressurize Test Characteristics:Indoor Temp: 65 °F Altitude: 5,761.0 ft Outdoor Temp: 28 °F Time Average Period: 10 seconds Test Date and Time:2024-12-09 12:01:42 10% Adjustment Applied: No Envelope Leakage Test Test Readings: Target (Pa)Bldg (Pa)Adj Bldg (Pa)Fan (Pa)Flow (cfm)Config Baseline -2.5 -50.0 -53.2 -50.7 -39.1 1,136.3 Ring A Test Equipment: Flow Device:Model 3 110V Fan Pressure Gauge:DG1000 Serial #: 14362 Calibration Date: 2023-07-11 Deviations from Standard: None Comments: None Envelope Leakage Test Page 2 of 2Report by TEC Auto Test 1.10.0 (238), © 2024 The Energy Conservatory, Inc.