HomeMy WebLinkAboutBlower Door Test ReportC31al1 J BUILDING LEAKAGE TEST Frostbusters & Coolth Co. PO Box 94 Basalt, CO 81621 '��JIiT Sk�l1► • C COOL' Note: Duct Testing Results on Page 4 of 4 Date of Test: 12/11/2024 Test File: 897 County Road 231 Blower Door Test 12-11-2024 Customer: Joaquin Bianco Technician: Fritz Diether 897 County Road 231 Project Number: Final Blower Door Test Silt, CO 81652 Phone: 970-369-4593 Building Address: Bianco Residence Email: btechconstruction@hotmail.com 897 County Road 231 Garfield County Silt, CO 81652 Test Results 1. Airflow at 50 Pascals: (50 Pa = 0.2 w.c.) 2. Leakage Area: 3. Building Leakage Curve 4. Test Settings: 5. Accuracy Level Infiltration Estimates 708 CFM50 (+/- 0.7 %) 2.53 ACH50 mr-- 38.9 in2 LBL ELA @ Flow Coefficient (C) = 54.7 (+ - %) Exponent (n) = 0.655 ( +/- 0.011 ) Correlation Coefficient = 0.99980 Test Standard: RESNET Multi -Point Test Test Mode: Depressurization Standard Level of Accuracy Test 1. Estimated Average Annual Infiltration Rate 2. Estimated Design Infiltration Rate Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: 39.1 CFM 0.14 ACH 9.8 CFM per person From the 2018 IECC: R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate not exceeding (3.00 ACH50) three air changes per hour in Climate Zones 3 through 8. Testing shall be conducted in accordance with RESNET/ICC 380, ASTM E779 or ASTM E1827 and reported at a pressure of 0.2 inch w.g. (50 Pascals). Where required by the code official, testing shall be conducted by an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. Building Passes at 2.53 ACH50. Winter: 74.5 CFM Summer: 57.7 CFM 0.27 ACH 0.21 ACH Mechanical Ventilation Guideline (based on ASHRAE 62.2-2010) Recommended Whole Bldg Rate: Base Rate: 48.6 CFM 48.6 CFM BUILDING LEAKAGE TEST Page 2 of 4 COOLSH Date of Test: 12/11/2024 Test File: 897 County Road 231 Blower Door Test 12-11-2024 Building Information Volume 16768 Surface Area Floor Area 1863 Height 22 # of Bedrooms 3 # of Occupants 4 Year of Construction 2024 Wind Shield L Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency % Cooling Fuel Cost Cooling SEER Location Climate Information Ventilation Weather Factor 0.80 Energy Climate Factor 19.00 Heating Degree Days 7850 Cooling Degree Days 28 Design Winter Wind Speed 1.6 mph Design Summer Wind Speed 10.9 mph Design Winter Temp Diff 77 deg F Design Summer Temp Diff 11 deg F Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) - Micromanometer Energy Conservatory DG700 p9S S UST 44��v �V o. BUILDING LEAKAGE TEST Page 3 of 4 cool Date of Test: 12/11/2024 Test File: 897 County Road 231 Blower Door Test 12-11-2024 Depressurization Test: Environmental Data Indoor Temperature (OF) Outdoor Temperature (OF) 32.0 Altitude (ft) 5600.0 69.0 Data Points - Data Entered Manually Nominal Baseline Adjusted Fan Building Pressure Building Pressure Pressure (Pa) (Pa) (Pa) -1.7 n/a n/a -60.0 -58.3 186.0 -55.0 -53.3 167.0 -50.0 -48.3 147.0 -45.0 -43.3 127.0 -40.0 -38.3 107.0 -35.0 -33.3 87.0 -30.0 -28.3 71.0 -25.0 -23.3 55.0 -20.0 -18.3 40.0 -15.0 -13.3 27.0 -1.7 n/a n/a Time Averaging Period: 10 None Nominal Adjusted Flow Flow Fan (cfm) (cfm) % Error Configuration 808 782 -0.1 Ring B 766 741 0.4 Ring B 719 696 0.6 Ring B 669 647 0.5 Ring B 615 595 0.0 Ring B 555 537 -1.1 Ring B 502 485 -0.5 Ring B 442 428 -0.4 Ring B 377 365 -0.4 Ring B 311 301 1.0 Ring B Deviations from Standard RESNET Multi -Point Test - Test Parameters p9S S UST 44��v �V o. BUILDING LEAKAGE TEST Page 4 of 4 cool Date of Test: 12/11/2024 Test File: 897 County Road 231 Blower Door Test 12-11-2024 Comments Additional Required Testing: From the 2018 IECC: R403.3.3 Duct testing (Mandatory). Ducts shall be pressure tested to determine air leakage by one of the following methods: 1. Rough -in test: Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa) across the system, including the manufacturer's air handler enclosure if installed at the time of the test. Registers shall be taped or otherwise sealed during the test. 2. Postconstruction test: Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa) across the entire system, including the manufacturer's air handler enclosure. Registers shall be taped or otherwise sealed during the test. Exceptions: 1. A duct air -leakage test shall not be required where the ducts and air handlers are located entirely within the building thermal envelope. 2. A duct air -leakage test shall not be required for ducts serving heat or energy recovery ventilators that are not integrated with ducts serving heating or cooling systems. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. R403.3.4 Duct leakage (Prescriptive). The total leakage of the ducts, where measured in accordance with Section R403.3.3, shall be as follows: 1. Rough -in test: The total leakage shall be less than or equal to 4 cubic feet per minute per 100 square feet of conditioned floor area where the air handler is installed at the time of the test. Where the air handler is not installed at the time of the test, the total leakage shall be less than or equal to 3 cubic feet per minute per 100 square feet of conditioned floor area. 2. Postconstruction test: Total leakage shall be less than or equal to 4 cubic feet per minute per 100 square feet of conditioned floor area. September 23, 2025: Duct Testing at Rough -In (Air Handler Not Installed): Test conducted by Fritz Diether, Frostbusters & Coolth Co. (970) 274-1141 Maximum Leakage Allowance: 1,863 sq ft of conditioned floor area X .03 = 55.89 CFM @ 25 PA Test Results: Supply Ducts: 29 CFM @ 25 PA Return Ducts: 12 CFM @ 25 PA Total: 41 CFM @ 25 PA. 41 CFM / 1,863 sq ft = .02. Duct System Passes