HomeMy WebLinkAboutBlower Door TestTesting Company: Name:EnergyPro Insulation Address:2892 I -70 B Grand Junction, CO 81501 Phone: 970-623-7327 Technician: Name: Credentials: Email: Building Information: Project ID:The Ace of Trades llc Address:244 Limberpine Circle Parachute, CO 81635 Year Built:2024 Geo-Tag Data:Latitude: Longitude: Timestamp: Customer Information: Name:The Ace Of Trades GC llc Address:3020 N 14th St Grand Junction , CO 81501 Phone: 970 433 3618 Email: wssimpson13@live.com Measured Leakage:2.98 ACH50 Leakage Target:3.00 ACH50 Compliance with Leakage Target:Pass Test ID:244 Limberpine Circle Purpose of Test:Envelope (IECC) Measured CFM50:1,166.4 Effective Leakage Area: 64.2 in² Building Volume:23,488.0 ft³Enclosure Surface Area: 1,590.0 ft² Coefficient (C):91.7 Exponent (n): 0.650 (assumed) Test Standard:RESNET 380 One-Point Test Mode: Depressurize Test Characteristics:Indoor Temp: 69 °F Altitude: 5,089.0 ft Outdoor Temp: 65 °F Time Average Period: 30 seconds Test Date and Time:2024-09-17 13:02:08 10% Adjustment Applied: No Envelope Leakage Test Test Readings: Target (Pa)Bldg (Pa)Adj Bldg (Pa)Fan (Pa)Flow (cfm)Config Baseline -1.6 -50.0 -50.8 -49.2 -38.7 1,130.0 Ring A Test Equipment: Flow Device:Model 3 110V Fan Pressure Gauge:DG1000 Serial #: 14362 Calibration Date: 2023-07-11 Deviations from Standard: None Comments: None Envelope Leakage Test Page 2 of 2Report by TEC Auto Test 1.10.0 (238), © 2024 The Energy Conservatory, Inc.