HomeMy WebLinkAboutAS-Built DrawingsE m m 0 r x PRESSURE DOSE TRANSPORT PIPE. INSTALLED 1.25 SCHD-40 2.0' MIN. DEPTH OF BURY. INSTALLED AT MIN. 2.5% TO ALLOW DRAIN BACK TO TANK. x PROPERTY LINE 1 INSTALLED 1/14" BALL VALVE FLUSH ASSEMBLY ON y,r TERMINAL END OF EACH DISTRIBUTION LATERAL THAT EXTENDS VERTICALLY THROUGH CHAMBER ENDCAP PENETRATION, HOUSED IN 10" VALVE BOX 1 (TYP. EA. ROW). INSTALLED 4" RISER PIPE INSPECTION PORTS ON EACH x CORNER CHAMBER ENDCAP OF THE BED (TYP.). x EXISTING FENCE INSTALLED CHAMBER END CAP ON ALL END CHAMBER ROWS ABSORPTIONITREATMENT FIELD W/ PRESSURE DOSED SAND FILTER BED INSTALLED 30 QUICK-4 PLUS CHAMBERS IN 3 ROWS WITH 10 CHAMBERS PER ROW FOR A TOTAL ABSORPTION AREA OF 563 S.F. THE CHAMBERS WHERE INSTALLED AT LEVEL GRADE. THE BOTTOM OF THE BED WAS EXCAVATEDTO MIN. DEPTH OF 3.5 FEET WITHIN THE NATIVE GRAVELY LOAMY SAND & BACKFILLED WITH 24-INCH SAND FILTER LAYER AND BACKFILLED WITH 12" NATIVE COVER OVERTOP OF CHAMBERS. Ix 1 1/4" PVC SCHD-40 CUSTOM PERFORATED PIPE DISTRIBUTION LATERALS. DRILLED 3/16-INCH DIA. ORIFICES EVERY 2.5-FEET ALONG THE PIPE; PLACED ON THE TOP OF THE ABSORPTIVE SAND SURFACE SECURED W/ WIRE STAPLES. ORIFICES ORIENTED BETWEEN THE FIRSTAND LAST UPWARD (12 O'CLOCK) CHAMBERS. FIRST AND LAST 3/16" ORIFICES ORIENTED DOWNWARD AT BOTH ENDS OF DISTRIBUTION LATERAL. I x 6,�z1 1 x 0�n9 x GRAPHIC �CALE 10 ❑ 5 1D 2D j IN FEET j finch =10 ft. 1250 Gallen Top Seam - 2CP IUOT W"H, with High Head Pump 47' • - Tap DESIGN NOTES 4•�� �` f View • Design per performance test per ASTM �` �,= •- �. C1227 ■ Top surface area 56.25 ft'G1rrAmW • f c 0 28 days; concrete - 6.000 PSI Min. 60' Installation: ■ Tank to be set on 5" min. sand bed or pea grovel 7Ml[ • Tank to be bockfilled uniformly on all sides in lifts less than 24" and 1 mechanically compacted-i -: ■ Excavated material may be used for bockfill, provided large stones are removed 24" Minimum 4 Excavation should be dewatered and Riser Height tonk filled with water prior to being put in a"ce for installation wrth Who to uickDbraortnect water table less than 2' below grade ■ Meets C1644-06 for reailient PWW BsIl Vfadlle connectors ■ Inlet and Outlet Identifled above pipe BOA ■ Delivered complete with internal piping Dbdmp How Control Panel to be mounted in sight •K• = . _..' ' r ' .. line of tank bw • 4' Maximum bury depth t 1 �Rub , ALLOWABLE BURY (Based on Water Table) WATER TABLE ALLOWABLE EARTH FILL 1'-a" 6, 0, 2' 0' 3'-0" DRY 4' - O` PLnp EpMws Ta dicta hVrL' m Ott e crtvkft 111IN III twlrlftp. Der K noun tp srtd smrt-W proasdirasj •Ser►ft cw"11:s ammillift Ibrffmd?benertos• � y Digging Specs Invert Dimensions Net Capacity Net Weight Min. 13' Long x 7' Wide Inlet Outlet Length Width Height Inlet Side Outlet Total Lid Tank Totol 56' below inlet $ " $4'arT 136' 60" 92' 843 gar 415 gal 1259 gai 3120 Ibs 10800 Ibs 14200 Ibis 0 VALLEY PRECAST, Inc. Buena Vista, Colorado Phone: 7'19-3954764 Fax: 7�19-395-3727 Website: www.valleyprecast.oam Email: tantdesk@valleypre�toom I OWTS. SEE SHEET C-2.0 10' r-0.6 PP-2 ]13 INSTALLED 2-COMPARTMENT 1250-GALLON CONCRETE SEPTIC TANK (VALLEY PRECAST ITEM # 1250t-2CP-HH) INSTALLED WITH (2) 24" DIA. BY 24" DEEP RIBBED PVC RISERS W/ LIDS AT THE SURFACE. INSTALLED ORENCO SIMPLEX EFFLUENT PUMP ASSEMBLY. (PVU57-1819-L) W/P300511 PUMP), W/ 1.25" DISCHARGE ASSEMBLY. DEPTH TO TOP OF TANK FROM PROPOSED GRADE IS APPROX. 1.75'. INSTALLED UNDERGROUND ELECTRICAL & CONTROL WIRES IN CONDUIT FOR PUMPS ORENCO (MODEL 5-1) PUMP CONTROL PANEL ]13 ETC ET[ ETC 1-BEDROOM DWELLING r+•s cr., FEE: + 0.5' ABOVE FIG,v - %V)-- 2-WAY CLEAN OUT 4" SCHD-40 GRAVITY SEWER 1.25" PRESSURIZED PIPE INSTALLED @ 2% MANIFOLD PIPE. 12,235 sq. ft. 0.280 acres 6129 5128 - - - ----------- 1 61-29 WIRE FENCE 6128 xx x CONNECT 1.25" TRANSPORT LINE TO 1.25" PRESSURE MANIFOLD. TRANSPORT PIPE INVERT MIN. 2" HIGHER THAN INVERT OF MANIFOLD TEE CONNECTION. USE 45°OR 22,5' FITTINGS. 1.25" SCHD-40 PVC PRESSURE MANIFOLD W/ INDIVIDUAL 1.25" TEES OR ELBOWS TO 1.25" CUSTOM PERFORATED DISTRIBUTION PIPE CHAMBER END CAP - ` - l a. F. i-12'� ROCKFORD DITCH LATERAL SYSTEM RECEPTION No. 23639 6227 x TYPICAL YARD LANSCAPED OR AGGR ATE PAVED SURFACE FACE 6' MIN. EXCAVATED MATERIAL COMPACTED TO 90% STANDARD PROCTOR 4"TVl SUITABLE BACKFILL OR CLASS 6 ROAD BASE 4" T!�q TRENCH CROSS-SECTION FOR SDR-.35 HDPE OR SCHED-40 PIPES N.T.S. SEED AND MULCH FINISH SURFACE CROWN FIELD TRENCH TO (MAINTAIN SUITABLE VEGETATIVE COVER DIVERT SURFACE WATER TOPSOIL 1.25" SCHD-40 PVC r- EXISTING GRADE �DISTRiBUTION MANIFOLD ' Design Calculations OWTS GENERAL NOTES: Design Calculations OWTS 1. THE OWTS A5 SHOWN ON THE PLAN AND THE DETAILS WERE DESIGNED BY 50PRI5 ENGINEERING. Installation of an OWTS with a minimum 3-bedroom capacity. 2. THE PROPOSED LOT CONDITIONS AND SURVEY INFORMATION BY SOPRIS ENGINEERING AND OTHERS From County adopted State Regulation 3, THE EXISITNG LOT CONDITIONS PER COUNTY GIS DATA BASE, AERIAL MAPPING, LIDARTOPOGRAPHY AND SURVEY _ Minimum population based on 3 bedrooms = 6 persons. INFORMATION BY 50PR15 ENGINEERING -_ First 3 bedrooms (2 persons/bedroom) Over 3 bedrooms (1 person per bedroom) ti Gallons per day per person =75 gal/person/day, No peaking factor 4. PRIMARY OWNER NAME AND ADDRESS: MACE, DAVID DYLAN Max. Design flow (Qd)gallons/day = (# of people) x (avg. flow)gal/person/day. 88 CEDAR ST CAR.BONDALE. CO 81623 Design flow Qd - 6 75=450 gpd I 5. LEGAL SUMMARY: COOPERTON TWNSTE. BLOCK: 9 LOT: 15 AND 16 INCLUDES LOT D Septic Tank Design: Used a 1250 gallon, two compartment septic tank with a bio-tube dosing assembly in WATER SERVICE PIPE the second chamber. 6. SITE ADDRESS: 88 CEDAR 5T, CARBONDALE, CO 81623 Sub Surface Conditions and Testing: 7. Parcel Number: 23932940901E I Subsurface soil investigations and USDA soil texture method tests were performed by Sopris Engineering on S. GARFIELD COUNTY PERMIT#: SEPT-6424 ISSUED 09/20/2020 April 6, 2020. The soils in the area of the proposed absorption field were sampled and characterized by 5 application of the USDA soil texture method test. The soils were tested to determine the hydraulic loading 9. CONTRACTOR: rate and to confirm the appropriate absorptive surface level suitable for an intermittent sand filter w w treatment system in native soils. The soils below nil to 3 inches of topsoil consist of medium dense gravelly loamy sand to sandy loam material to 0.3 to 4 feet belowthe surface. The soil appears to be consistent across the site. I The native soils sampled from 1-2 feet below the surface are characterized as a soil type 1 consisting of loamy sand to sandy loam texture with moderate granular structure. Soils below 2 feet are increasingly rocky becoming R-1 soils with more than 30% rack content smallerthan 3/4". This soil has an effective loading rate for conventional soil treatment of 0.8 Gal/S.F./day, for a level 1 conventional treatment system. Due to limited area, rock content and to provide optimal treatment an intermittent sand filter is recommended. No free water was encountered in excavations on site. Groundwater levels are expected to be below 10 feet from the existing surface grades. A The soils are suitable for the installation of a sand filter treatment bed system that was fully pressure dosed and utilize 24-inches of washed concrete sand. Intermittent Sand Filter Treatment Unit/Absorption System Design: I The treatment/absorption field was designed based on utilizing the effective Long Term Acceptance Rate (LTAR) for an intermittent sand filter treatment system utilizing pressure dosed distribution laterals and _ gravelless chamber units as distribution spray shields. The new treatment system consists of a fully pressure dosed sand filter Treatment bed System with a 24-inch layer of filter sand (ASTM-33, "Washed ASTM-33 Concrete Sand"). I, .. GRAVEL" .:. DRIVEiAIA - ~' Long Term Acceptance Rate (LTAR) Considering the application of the new state regulation 43: Receiving Wastewater Treatment Level 1; loading rate for sand filter is (0.8 gal./S.F./day) for the minimum µ. =- '- 24' depth of secondary sand treatment media; __ - .: .; •.. _ : Loading factors; (Table 10-2, pressure dosed application bed = 1.0) EXISTING A(sf) = Qd.: A = Area; C12 CMP UULVERT •} LTAR LTAR = 1.0 Gal/S.F./day for secondary sand, ASTM-33, "Concrete sand" ti _ _ - Qd = flow (gal/day) = 450 gpd LF.1=1.0 pressure dosing 0-c A(sf) = 450 gpd x 1.0 = 562.5 S.F. 0.8 Gal/S.F./day Excavated a single 47' by 12' bed to a maximum 3.5' depth below finish grade. Backfilled with 36-inches of ASTM-33, concrete sand. Installed 3 rows of custom perforated 1.25-inch distribution lateral on top of sand layer in the bed and cover with 10 Quick-4 Plus chambers per row for use as pressure dose spray shields, as delineated on the plan. x W W Pump Selection for a Pressurized System - sinale family Residence project Mace Residence 88 Cedar, 1450 gpd. P3011. PDSF Param4tQrs and DiscnargeAasemblySize 1.25 Inches Tran s port Len gth 11 feel Transport Plpe Class 40 Transport Llne Size 1.25 Indies DlstntwbngvatveModel None Max Elevation Lift 5 feel Manl101dl-eng1l a feel s5p Manifoldpipe Class 40 Manlfolit Pipe Sim 1.25 Inches NumGer gf Laterals per Cell 3 Lateral Lengm 42 feet LatefalPipe Class 40 Lateral Pips Size 1.25 Inches Dnace Sire 3116 Inches 0r04,eSpacng 2.5 feel Residual Head 2.5 Zel xoe FTowMeter None Inches 'Ad"sFnchanLosses 0 feet CdtCGEdilan5 Cxp MlnlmumFlow Rate Per Onflce 0.69 gpm F Numb er of Orifices per Zone 51 Tow now Rate per zone 35.6 gpm rd4 NumiFef of Lffieral s per Lane 3 L7 %FIpwDllfereniallstLasfOrlgce 5.2 9G E Tranaporl Velocity 7.7 Tpa Frictional Head Losses a Loss through Olscharge 9.9 feel h Loss In7ranspofl 1.7 feet Lassmroughvatre TO feet rid Loss In Mangold 0.3 feet Loss In Lalarals 0.3 feel Loss through Flowmeter 0.0 feel 'Atld-on'Frlctieo Losses (.t] feet Pipe Volumes Vol of Transporl Line 0.9 gals Vat of Manifold 0.6 gals da vat or Lalerals per zone 9.8 pats Total volume 113 gals Minimum Pump Requirements Deslgn Row Rate 35.0 gpm TnlalOynamicHead 10.7 feet 12" - 38' MIN. - MAX. 0.5' (TYP.) 24" u UNDISTURBED EARTH - SCREENED BACKFILL:..-'-,:1 COSTUME PERFORATED PRESSURE PIPE WITH NATIVE SOIL y 24" [ •''.:. ORIFICES AT 12 O'CLOCK 1.25" TEE CONNECTION SECURE PIPE WITH PUSH IN INTERMITfENTSAND FILTER LAYER EFFECTIVE 5f2E r STAPLES,` ..: Q.ZS-0.6 MM, WITH UNIFORM. CO€F.=<4.0 U5€ QUICK-4 INFILTRATOR I - / CONCRETE SAND-ASTM-33 OR EQUAL BIO DIFFUSER /\///�\/\ / MACHINE COMPACT AND LEVEL TOP SURFACE SPRAY SHIELDSL Z PRESSURE DISTRIBUTION 12'-MIN• PIPE CONNECTED THROUGH END CAP NOTE: NATIVE GRAVELLY LOAMY SAND SOIL CUSTOM PERFORATED DISTRIBUTION WITH COBBLES THE INTERMITTENT SAND FILTER BED MUST BE LEVEL, INSTALL CHAMBERS WITH INLET AND LATERAL PIPE END CAPS OVER SAND LAYERT FOR USE AS SPRAY SHEILDS. INSTALL INDIVIDUAL DISTRIBUTION LATERALS TO THE HEAD OF EACH CHAMBER ROW FROM A MAINIFOLD SCARIFY/TILL BOTTOM SURFACE AND CONNECTING EACH CHAMBER ROW. CUSTOM PERFORATED PIPE TO BE LAID ON TOP OF EXCAVATION SIDE WALLS THE SAND LAYER WITH ORIFICES ORIENTED UPWARD EXCEPT THE FIRST AND LAST ORIFICES TO BE ORIENTED DOWNWARD. INSTALL A 4" VERTICAL INSPECTION RISER FROM THE MOLDED CUT OUT ON THE LA5T CHAMBER IN EACH ROW. INSTALL A BALL VALVE AT THE END OF THE DISTRIBUTION LINE ACCESSIBLE FROM THE INSPECTION PORT TO ALLOW FLUSHING OF THE LINE. THE VALVE IS CLOSED FOR NORMAL OPERATION. P T�S'�SU�T �D���Td I �1/_T_r�'1�1� _�TTT����T r���_�']� T1LTT1R <y �'YT�'-11� 26 30 39 Net Discharge (gpm) R MACE 88 CEDAR EFFLUENT DISCHARGE TO SAND FILTER BED DOSING CALLS TOTAL VOL 1.25" TRANSPORT PIPE 0.7 GAL SU M TOTAL PI PE/DRAIN BACK VOL 0.7 GAL VOL 1.25" MAINIFOLD PIPE 0.5 TOTAL VOL 1.25" DISTRIBUTION LATERALS 8.0 VOL TO DELIVER 4X DISTRIBUTION LATERALS 32.1 GAL TOTAL VOL All PIPES, + DRN BACK 8.7 GAL TOTAL VOL PER PUMP CYCLE (4X LAT VOL) 40.9 VOL 2ND COMP 1200 GAL TANK GAL 416.0 gal DOSING COMPARTMENT STAGE VOL GAL/IN 8.5 GAL/IN ON/OFF FLOAT SPREAD SETTING 4.8 IN MIN DESIGN PUMP DISCHARGE RATE 35 GPM PUMP RUN TIME 1.2 MIN MIN PUMP THE TO DELIVER DOSE 0.9 MIN PUMP TIME TO FILL PIPES 0.2 MIN DEMAND DOSE FLOAT LEVEL SETTINGS 1000 GAL SECOND COMP TANK BIO TUBE FILTER (PVU57-1819-L W/P300511 PUMP) FLOAT / LL BELOW TOP OF TANK DEPTH LL FIR BOT FLOAT FR TOT STAGE ABOVE BOTTOM INT TANK IN IN HIGH LIQUID LEVEL INV IN 49 64.0 3RD FLOAT HL ALARMIOVERRIDE 46.0 18.0 2ND FLOAT PUMP ON 43.0 21.0 1 ST FLOAT REDUNDANT OFF 38.2 25.8 Orenco 'Systi wW Incorporated rairnKl'?4 dry lk y zlr IYfi.W Lbn Srnrrawr� Syevm U_•.e - hmn tm.e 6yenrcy, Parr 0 0.s9n Pent C) w i OPRIS ENGINEERING, LLC. CIVIL CONSULTANTS 502 MAIN STREET CARBON DALE_ CO 8 162 3 (970) 704-0311 FAx: (970}7fl4-0313 DESIGNED BY PER 11/26124 DRAWN BY PER 04/17/20 CHECKED BY YTN 12/17/24 DATE: DEC 31, 2024 JOB NO. 19219.01 0 Ljj J W Z co Q W a W_ p W JILIJ LU 0 L.I) W QD � Uj w r U) Z 0 C!] O 0 O < J W 0 W 0 0 Uj Uj F_ -^ v I a 28377 1. 371 ZdZ �7177xrrC+ - DATE REVISION TITLE. OWTS AS -CONSTRUCTED PLAN DRAWING NO. C-1.0