HomeMy WebLinkAboutRes Check Energy ReportGenerated by REScheck-Web Software Compliance Certificate Project STANLEY F-10 Energy Code: Location: Construction Type: Project Type: Project SubType: Orientation: Conditioned Floor Area: Glazing Area Climate Zone: Permit Date: Permit Number: All Electric ls Renewable Has Charger Has Battery: Has Heat Pump: Construction Site: 138 RIVER PARK LANE GARFIELD COUNTY, CO 81601 Ceiling: Flat Ceiling or Scissor Truss Wall: Wood Frame, 16" o.c. Orientation: Left side Window: Vinyl Frame Orientation: Left side Wall l:Wood Frame, 16" o.c. Orientation: Back Door: Glass Door (over 50% glazing) Orientation: Back 2018 |ECC Garfield €ounty, Colorado Single-family New Construction None Bldg, faces 27O deg. from North 4,6941t2 L2o/o s (8499 HDD) true false true false false Owner/Agent: STAN LEY BARTLOMIEJCZUK 162 W. SIXTH STREET GLENWOOD SPRINGS, CO 81601 970-948-9232 ABANDDTLLC@GMAIL.COM Designer/Contractor: BRADJORDAN JORDAN ARCHITECTURE INC PO BOX 103L GLENWOOD SPRINGS, CO 81602 970-618-6690 BRADJORDANARCHITECT@GMAIL.C OM .-.ua \ Compliance: 9.27o EetterThan Code Maximum UA: 686 Your UA: 623 The % Better or Worse Than Code lndex reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provlde an estimate of energy use or cost relative to a minimum-code home. Slab-on-grade tradeoffs are no longer considered in the UA or performance compliance path in REScheck. Each slab-on-grade assembly in the specified climate zone must meet the minimum energy code insulation R-value and depth requirements. Envelooe Assemblies 3,225 1,458 r62 L,033 48 49.0 20.0 84 76 24 47 13 84 78 49 48 !4 0.0 0.0 0.0 0.026 0.059 0.150 0.059 0.280 0.026 0.060 0.300 0.060 0.300 Compliance: Passes using UA trade-off Cavity R-Value Cont, Prop, Req. Prop. R-Value U-Factor U-Factor UA Req UA Gross Area or Perimeter Assembly 20.0 Project Title: STANLEY F-1-0 Data filename: Report date: 72105124 Page L of10 I Cont, R'Value Prop. Req, U-Factor U-Factor Prop, UA Req UA Gross Area CavityAsscmblyor Perimeter R,Valuc Window 1: Vinyl Frame Orientation: Back Wall 2: Wood Frame, 16" o.c. Orientation: Right side Door 2: 5olid Door (under 5O% glazing) Orientation: Right side Door 1: Glass Door (over 50% glazing) Orientation: Right side Window 2: Vinyl Frame Orientation: Right side Wall 3: Wood Frame, 16" o.c. orlentation: Front Door 3: Solid Door (under 50olo glazing) Qrientation: Front Window 3: Vinyl Frame Orientation: Front Crawl Wall: Solid Concrete or Masonry Wall height:3.0' Depth below grade: 3.0' lnsulation depth: 3.0' 0.150 0.059 0.400 0.280 0.150 0.059 0.400 0.150 0.0s3 0.300 0.060 0.300 0.300 0.300 0.060 0.300 0.300 0.055 56 63 72 L4 28 66 B 26 80 188 1,439 240 48 94 L,224 28 87 2,769 20.0 0.0 20.0 0.0 19.0 0.0 2A 62 96 13 l4 65 11 13 77 Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meei the 20L8 IECC requirements in REScheck Version : REscheck-Web and to comply with the mandatory requirements listed in the REscheck lnspection Checklist. BRAD JORDAN - ARCHITECT E'LaZ 12-06-24 Name - Title Date Project Title: STANLEY F-LO Data filename: Report date: l2l05l24 Page 2 ofL0 REScheck Software Version REScheck-Web lnspection Checkl st Energy Code: 2018 IECC Requirements: 0.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Additional Comments/Assumptions: Field Verlfied Value Complies?Comments/Assumptlons Section # & Reo.lD Pre-lnspection/Plan Review Plans Verifled Value 103.1, 103.2 lPRlll ii' Construction drawings and documentation demonstrate energy code compliance for the I building envelope. Thermal envelope represented on construction documents. EComplies :DDoes Not :flNot observable rflNot npplicable 103.1, 103.2, 403.7 lPR3l1 at' Construction drawings and documentation demonstrate ienergy code compliance for lighting and mechanical systems Systems serving multiple dwelling units must demonstrate compliance with the IECC Commercial Provisions. EComplies :lDoes Not flNot observable Druot npplicable 302.1, 403.7 IPR2]2 !l, Heating and cooling equipment is sized per ACCA Manual S based on loads calculated per ACCA Manual J or other methods approved by the code official. Heating: Btu/hr_ Cooling: Btu/hr_ Heating:Btu/hr_ Cooling:Btu/hr_flNot Observable flNot Applicable 2 Medium (Tier 2)3 (Tier 3)Low1I(Tier Project Title: STANLEY F-10 Data filename: Report date: 12lOSl24 Page 3 ofLO R.R-table for values. lh e Env el o p e Assernblies2.11 Does Not Unvented crawl space wall insulation R-value.lF07ll o iilNot Observable i[1Not Applicable 303.2 lFoSlrg Unvented crawl space wall insulation installed per manufacturer's instructions. ies Not Applicable Otrservahle Not i Unvented crawl space continuous ivapor retarder installed over jexposed eafth, joints overlapped iby 6 in. and sealed, extending at jleast 6 in. up and attached to the 1wall. 402.2 L.1 lF09l1 CI tes Not Applicable Does Not Observable Unvented crawl space wall insulation depth of burial or distance trom top of wall. iEcomplies iEpoes t'tqt i[Not observable j[ruot applicable 402.2 tn,tn, lFo10l1 & .1L See the Envelope Assemblies table for values. Not Observable lSnow- and ice-melting system icontrols installed.Not Observable Applicable Additional Comments/Assumptions: I High lmpact (Tier L) I Z J Medium lmpact (Tier 2)3 Low lmpact (Tier 3) Project Title: STANLEY F-10 Data filename: Report date: lUAsn4 Page 4 of10 Fleld Verified Value Complles?Comments/AssumptionsPlans Verified Value Section # & Req.lD Framing / Rough-ln lnspection see the Envelope AssembliesDoor U-factor table for values. U-U- U-U- IComplies Etrtot See the Envelope Assemblies table for values. : clazing U-factor (area-weighted : average). 402.7.t, 402.3.4 lFRlli 'iJ 402.L.1, 402.3.r, 402.3.3, 402.5 lFR2l1 flComplies EDoes Not INot Observable nNot Applicable nDoes Not ,INot Observable 303.1.3 lFR4l1 U-factors of fenestration products are determined in accordance with the NFRC test procedure or taken from the default table. tlComplies [Does Not INot Observable flruot npplicable 402,4.r.r lFR23l1 ti !. Air barrier and thermal barrier installed per manufacturer's instructions. lComplies [Does Not INot Observable Enot Applicable 402.4.3 lFR2011 il Fenestration that is not site built is listed and labeled as meeting AAMA A /DMA/CSA 101/1.S.2/A440 or has infiltration rates per NFRC 400 that do not exceed code limits. IComplies [Does Not ENot Observable lNot Applicable lc-rated recessed lighting fixtures sealed at housing/interior finish and labeled to indicate <2.0 cfm leakage at 75 Pa. lComplies EDoes Not INot observable lNot Applicable 402.4.5 lFR1612 Supply and return ducts in attics insulated >= R-8 where duct is>: 3 inches in diameter and >= R-6 where < 3 inches. Supply and return ducts in other portions of the building insulated >= R-6 for diameter >= 3 inches and R-4.2 for < 3 inches in diameter. EComplies lDoes Not INot Observable Eruot applicable 403.3.1 lFR12l1 403.3.2 lFR13l1 Ducts, air handlers and filter , boxes are sealed with : loints/seams compliant with lnternational Mechanical Code or lnternational Residential Code, as nDoes Not INot Observable nNot Applicable icable. 403.3.s lFR1513 Not Building cavities are not used as ducts or plenums. INot observable ENot Applicable 1 High lmpact (Tier 1)2 Medium lmpact (Tier 2)3 Low lmpact (Tier 3) Project Title: STANLEY F-l0 Data filename: Report date: I2lO5l24 Page 5 of10 Sectlon # & Req.lD Framing / Rough-ln lnspection Plans Verifaed Value Fleld Verified value Complles?Comments/Asrumptions 403.3.7 lFR2B13 v :Ducts declared to be within the : conditioned space are either 1) ': :completely within the continuous , air barrier and within the building ' thermal envelope, 2) burled l within ceiling insulation in accordance with Section R403.3.6 and the air handler is , located completely within the continuous air barrier and within the building thermal envelope and the duct leakage is <= 1.5 : cfm / 100 square feet of conditioned floor area served by .the duct system, or 3) the ceiling . insrrlation R-valLre installed l against and above the insulated : duct >= to the proposed ceiling l insulation R-value, less the R- value of the insulation on the lEComplies :IDoes Not INot Observable ;Eruot npplicaOle 403.4 lFR1712 \!) HVAC piping conveying fluids above 105 eF or chilled fluids below 55 sF are insulated to >R- 3. R-R-:EComplies inPoes ttot ,INot Observable ;Eruot appticaOte 403.4.L lFR24l1 iProtection of insulation on HVAC , piping. ,flcomplies lflDoes Not Iftot Observable Eruot applicable 403.5.3 lFR1812 I Hot water pipes are insulated to R- >R-3. R.lEComplies i ;EDoes lvot i intrtot Observable : 1[ruot Rpplicable i 403.6 lFR1912 Automatic or gravity dampers are installcd on all outdoor air , intakes and exhausts. ' flComplies iflDoes Not ,flNot observable DNot npplicable Additional Comments/Assumptions: 1 High lmpact (Tier 1)2 Medium lmpact (Tier 2)3 Low lmpact (Tier 3) Project Title: STANLEY F-1"0 Data filename: Report date: L2lO5l24 Page 6 of10 Not Observable Applicable All installed insulation is labeled or the installed R-values provided. R-_ I Wood fl Mass fl Steel iEcomplies iEooes tttot iEttot observable ifltrtot Applicable table for vatues, the Envelope Assemblies402.L.L, 402.2.5, 402.2,6 ltN311g Wall insulation R-value. lf this is a mass wall with at least % of the wall insulation on the wall exterior, the exterior insulation requirement applies (FRLO). R-I Wood I uass I Steel EComplies EDoes trtot [Not Observable Etrtot Rpplicable Wall insulation is installed per manufacturef s instructions. 303.2 ltN411 Additional Comments/Assumptions: (Tier z1Medium 3 LowI Project Title: STANLEY F-10 Data fllename: Report date: 12105124 Page 7 ofL0 Sectlon* & Req.lD Flnal lnspectlon Provlslons Plans Verifled Value Field Verlfied Value Complles?Comment$/Assumptions 402.L.1, 402.2.1, 402.2.2, 402.2.6 lFt111 tEComplies :Dooes Not :INot Observable rINot Applicable . Ceiling insulation R-value.tSee the Envelope Assernblies :table for values. R-R- fl wood fl Steel I Wood n Steel 303.1.1.1, ,Ceiling insulation instdlled per303.2 manufacturer's instructions.lFI2l1 :Blown insulation marked every :300 ftr.'E Itr ,EComplles rEooes Not Not Observable Not Applicable Vented attics with air permeable insulation include baffle adjacent to soffit and eave vents that extends over instrlation. ,EComplies '[Does Not 'INot ObservablerINot Applicable 442.2.3 IFt22l2 Attic access hatch and door insulotion :-R.voluc of thc , adjacent assembly. [Complies i EDocs Not l LINot Observable flNot Applicable l R-R-402.2.4 lFr3l1 , Blower door test @ 50 Pa. <=5 ,ach in Climate Zones 1-2, andi<=3 ach in Climate Zones 3-8. ACH 50: rlNot iItttot 402.4.'1,.2 lFt 1 711 ACH 50 ;[Compties lEDoes ltot Observable : Applicable , Ducts are pressure tested to determine air leakage with :either: Rough-in test: Total leakage measured with a , pressure difterential of 0.1 inch 'w.9. across the system including the manufacturer's air handler ienclosure if installed at time of test. Postconstruction test: Total ,leakaqe measured with a pressure differential of 0.1 inch cfm/100 cfm/100 ft2 ft2 w.g. across the entire system including the manufacturer's air handler enclosure. 403.3.3 lFt2711 lComplies rEooes ruot INot Observable rEruot appllcable :Duct tightness test result of <=4 cfm/100 ftz across the system or :<=3 cfm/100 ft2 without air :handler @ 25 Pa. For rough-in tests, verification may need to cfm/100 cfm/100 ; OCCur duri Frami lnspection iINot observable rflNot Applicable lflooes not Complies403.3.4 lFr4l1 403.3.2.1 ,Air handlpr leakage d LFl24lt by manufacturer at < :design air flow. ,[lComplies Eooes trtot .INot Observable:INot Applicable esignated =2o/o ot Not code ns. plies 403.1.1 lFt912 403.r.2 lFt1012 Heat pump thermostat installed on heat pumps. Programmable thermostats installed for control of primary heating and cooling systems and initially set by manufacturer to ENot observable nNot Rpplicable :flDoes ttot INot Observable INot Applicable Circulating service hot water systems have automatic or accessible manual controls. EDoes Not ENot observable ENot applicable pli€s403.5,1 lFt11l2 1 High lmpact (Tier 1)2 Medium lmpact (Tier 2)3 Low lmpact (Tier 3) Project Title: STANLEY F-10 Data filename: Report date: L2lO5/24 Page 8 of10 Section # & Reo.lD Final lnspectlon Provisions Plans Verified value Field Verified Value Complles?Comments/Assumptions 403.6.1 lFr2512 All mechanical ventilation system fans not part of tested and listed HVAC equipment meet efficacy and air flow limits per Table R403.6.1. LJComplies lDoes Not INot Observable Eruot Applicable 403.2 lFt2612 Hot water boilers supplying heat through one- or two-pipe heating systems have outdoor setback control to lower boiler water temperature based on outdoor temperature. lComplies lDoes Not flNot observable Eruot npplicable 403.5.1.1 lFt28l2 Heated water circulation systems have a circulation pump. The system return pipe is a dedicated return pipe or a cold water supply pipe. Gravity and thermos- syphon circulation systems are not present. Controls for circulating hot water system pumps start the pumP with signal for hot water demand within the occupancy. Controls automatically turn off the PumP when water is in circulation looP is at set-point temperature and no demand for hot water exists. DComplies [Does Not ENot Observable nuot Applicable 403.5.1.2 lFt29J2 Electric heat trace systems comply with IEEE 515.1 or UL 5 15. Controls automatically adjust the energy input to the heat tracing to maintain the desired water temperature in the piping. [JComplies [Does Not ENot Observable nruot npplicable 403.5.2 lFt3012 Demand recirculation water systems have controls that manage operation of the pump and limit the temperature of the water entering the cold water Complies EDoes Not trn Not Observable Not Applicable to <= 104sF 403.5.4 lFr31l, Drain water heat recovery units tested in accordance with CSA 855.1. Potable water-side pressure loss of drain water heat recovery units < 3 psi for individual units connected to one or two showers. Potable water- side pressure loss of drain water heat recovery units < 2 psi for individual units connected to three or more showers. Complies lDoes Not DNot Observable Eruot npplicable 404.r lFr6l1 9oo/o at more of Permanent fixtures have high efficacy lamps. lComplies DDoes Not flNot observable Itrtot Applicable 404.7.L lFt2313 Fuel gas lighting systems have no continuous pilot light. nComplies flDoes Not nNot Observable [ruot 401.3 lFl712 Compliance certificate posted IComplies [Does Not INot Observable [ruot npplicable 1 Hiqh lmpact (Tier 1)2 Medium lmpact (Tier 2)3 Low lmpact (Tier 3) Project Title: STANLEY F-10 Data filename: Report date: 12105124 Page 9 of10 syst€ms nave been provlded. mechanical fof heating Additional Comments/Assurnptionsl t_Low lmpact (Tier Project Title STANLEY F-lO Data filename: ReBort date LAA:5124 Page 10 ofL0 2018 IECC Energy Effi cie ncy Ce rtificate Above-Grade Wall Below-Grade Wall Floor Ceiling / Roof Ductwork (unconditioned spaces): Window Door Heating System; Cooling Water Name: Comments 20.oo 19.OO o.oo 49.OO o.15 o.40 Date: R-Valuelnsulation Rating Glass & Door Rating U-Factor SHGC Heating & Cooling Equipment Efficiency