Loading...
HomeMy WebLinkAboutBlower Door TestI ILAff Retrotec rCloud Quality Assurance Report Single Direction Multi Point Blower Door Test PASS Your Result: 2.74 ACH50 (364.15 CFM50 * 60 / 7965 ft3) Target <= 3 ACH50 Test Information Test Name 411 County Road 237 Test Date 2024-12-30 09:23 AM (PST) Export id LNBONXBX Company Name Dexter Diagnostics Technician Name Amanda Poindexter Technician Email dexterdiagnostics@gmail.com Building Information Address 411 County Road 237 City Silt State CO Zip/postal Code 81652 Country United States Year Constructed 2024 Elevation 5748 ft Address Verified? Yes Building Latitude, Longitude 39.569743,-107.677095 GPS validation Tester location not verified Estimated Distance From Address Not available Test Equipment Fan Model Retrotec 5000 Fan Serial Number 5FN105365 Pressure Gauge Model Retrotec DM32X Gauge Serial Number 502769 Environmental Conditions Pre -test Indoor Temperature 60 OF Pre -test Outdoor Temperature 29 OF Wind Speed 4 MPH Average Barometric Pressure 101.6 kPa Test Dimensions Conditioned Floor Area 885 ft2 Envelope Area 2841 ft2 Volume 7965 ft3 f Retrotec rCloud Test Results Summary Test Type Single Direction Multi Point Blower Door Test Flow Reference Pressure 50 Pa Time Averaging 10 seconds Corrected Flow 364.15 CFM @ 50 Pa Air Changes Per Hour 2.743 Percent Uncertainty 4.1 % Correlation, r 0.994 Intercept 17.418 Slope, n 0.777 Test Results Test Data Set 1 Flow Direction Depressurize Gauge Location Inside Baseline, initial (Pa) -0.08 -0.08 -0.11 -0.14 -0.14 -0.14 -0.16 -0.17 -0.2 -0.24 Baseline Duration 10 seconds Average baseline -0.15 Pa Measured Pressure (Pa) -15.1 -22.62 -29.94 -37.56 Fan Pressure [5000 - B1] (Pa) 111.84 Fan Pressure [5000 - B2] (Pa) 58.14 83.85 110.49 Fan Pressure [5000 - B4] (Pa) Flow (CFM) 152.76 206.11 250.42 292.59 Measured Pressure (Pa) -44.67 -52.34 -59.57 Fan Pressure [5000 - B1] (Pa) Fan Pressure [5000 - B2] (Pa) 138.39 Fan Pressure [5000 - B4] (Pa) 43.51 50.6 Flow (CFM) 332.86 407.95 438.66 Baseline, final (Pa) -0.29 -0.34 -0.37 -0.4 -0.45 -0.51 -0.57 -0.58 -0.57 -0.42 Baseline Duration 10 seconds Average baseline -0.45 Pa �rerrni'� Test Notes No notes entered. Flow Equation Parameters - Retrotec Calibrated Flow Parameters Retrotec rCloud Fan Last Calibrated: 2024-09-11 Fan Model Retrotec 5000 Fan Serial Number 5FN105365 Fan Last Calibrated: 2024-09-11 Units Used For Flow Parameters in Equation CFM Fan pressure (FP) is the measured fan pressure when using a self -referenced fan or when the room pressure is negative. If using a fan which is not self -referenced, and the room pressure is positive, fan pressure is calculated by subtracting the measured room pressure from the absolute value of the fan pressure. If PrA is greater than 0 or fan is self -referencing: FP = jPrBj - PrA If PrA is less than 0 or fan is self -referencing: FP = PrB Flow calculations are not valid if fan pressure is less than either MF or (K2 x IRPI) Fr = ran pressure, Kr = room pressure Range N K K1 K2 K3 K4 MF Open 0.4990 555.2054 0.0000 0.3000 0.0000 1 10 A 0.5030 290.8751 0.0000 0.4000 0.0000 1 20 B8 0.5270 121.5413 0.0000 0.7000 0.0000 1 35 flow = (FP - RP x K1 )n x (K + K3 x FP) x K4 Range A B C D F G K2 MF B4 0.0000176573 -0.01530302 6.2742 138.42 0.59 50 0.8000 40 B2 0.0000025309 -0.00466154 2.7545 25.71 0.92 50 1.0000 50 B 1 0.0000027369 -0.00313712 1.4891 10.71 0.45 50 1.0000 60 B74 0.0000007960 -0.00095010 0.5900 18.00 0.15 25 0.8000 35 B47 0.0000002690 -0.00035905 0.2435 12.05 0.09 25 1.0000 50 B29 0.0000001110 -0.00014900 0.0920 4.40 -0.02 25 0.6000 50 flow = (A x FP3) + (B x FP2) + (C x FP) + D +((G - RP) x F)