HomeMy WebLinkAboutHeat Calcsrfitbtthatlttllla Manual S Compliance Report Bedrooms AHU Job: Date: By: Plan: 2299 Elk Springs Reside... Nov 15,2024 lsaac Ross 11t06t242sGrfill Project lnformation For:Ek Springs Residence, Pegasus Custom Homes 2295 Elk Springs Dr., Glenwood Springs, CO 81601 Cooling Equipment Design Conditions Outdoor design DB: Outdoor design WB: lndoor design DB: lndoor RH: Sensible gain: Latent gain: Totalgain: Estimated airflow 100% of load 0% of load 143o/o of load SHR: TOTo 92.7"F 58.4'F 75.0'F 5Oo/o 32621 0 32621 1400 Btuh Btuh Btuh cfm 79.2"F 62.XF Entering coil DB: Entering coilWB Manufacturer's Performance Data at Actual Design Conditions N a a Equipment type: Manufacturer: Actualairflow: Sensible capacity Latent capacity: Totalcapacity: Split AC Lennox 1400 32550 1 3950 46500 cfm Btuh Btuh Btuh Model: ML1 8XC2-048-230A**+CK40DT-50/60C-01 Heating Equipment Design Conditions Outdoor design DB: lndoor design DB: Equipment type: Manufacturer: Actualairflow: Output capacity: Heat loss 63703 Btuh Model: EL297 DF 1 1 0XV60C-. 1260/o ol load EnteringcoilDB: 68.8'F Temp. rise:59 "F -2.0"F 72.0"F N. N s ta Manufacturer's Performance Data at Actual Design Conditions Gas furnace Lennox 1400 cfm 80256 Btuh Meets all requirements of ACCA Manual S. {tf+ *",:1g",llty".*' *,n n,-", u* u niv er sar 20 2s zs. o. os R s u 6 0560 2024-Nov-18 15:11:29 Page 1,g/ccr....Wrightsoft HvAc\Project\22gg Elk Springs Dr.rup Calc = MJ8 Front Door faces: N Irrl Manual S Gompliance Report Living AHU Job: Date: By: Plan: 2299 Elk Springs Reside... Nov 15,2024 lsaac Ross 11t06t24 Project lnformation For:Ek Springs Residence, Pegasus Custom Homes 2299 Elk Springs Dr., Glenwood Springs, CO 81601 Cooling Equipment Design Conditions Outdoor design DB: Outdoor design WB: lndoor design DB: lndoor RH: Sensible gain: Latent gain: Totalgain: Estimated airflow: 99% of load 0% of load 142o/o ol load SHR: 7oo/o 92.7"F 58.4'F 75.0'F 50% 32734 0 32734 1600 Btuh Btuh Btuh cfm 77.trF 62.1'F Entering coil DB: Entering coilWB Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split AC Manufacturer: Lennox Actualairflow: 1600 Sensiblecapacity: 32550 Latent capacity: 13950 Totalcapacity: 46500 Model: ML1 8XC2-048-2304*.+CK40DT-50/60C-01 cfm Btuh Btuh Btuh Heating Equipment Design Conditions Outdoor design DB lndoor design DB: Equipment type: Manufacturer: Actualairflow: Output capacity: -2.0"F 72.O"F Gas furnace Lennox 1600 cfm 64204 Btuh Manufacturer's Performance Data at Actual Design Gonditions Heat loss 56977 Btuh Model: EL297DF090XV60C-* 1 13lo of load Entering coil DB: 70.5"F Temp. rise:47 "F Meets all requirements of ACCA Manual S {} y.:1ql*:*-9!:' *,n n"", o"r u niv ersar zoz3 23.o.os Rsu6 0560 2024-Nov-18 15:'11:29 Page2^s.ffi.Wrightsoft HvAc\Project\22gg Elk Springs Dr.rup Calc = MJB Front Door faces: N Gom ponent Constructions Entire House Job: 2299 Elk Springs Reside... Date: Nov 15,2024 By: lsaac Ross Plan: '11106124 ect lnformationPro For:Ek Springs Residence, Pegasus Custom Homes 2299ElkSprings Dr., Glenwood Springs, CO 81601 Design Gonditions Location: Rifle Garfield County AP, CO, US Elevation: 6896 ftLatitude: 40'NOutdoor: Heating Drybulb ('F) -2 Dailyrange ('F) Wet bulb ('F) Wind speed (mph) 15.0 glin 93 34 58 7.5 Coo (H ) Indoor: lnd oor temperature ('F) Design TD CF) Relative humidity (%) Moisture difference (gr/lb) lnfiltration: Method Construction quality Fireplaces Heating 72 74 30 40.1 Simplified Average 2 (Average) Cooling 75 18 50 -44.O Gonstruction descri ptions Walls 12F-Osw: Frm wall, wd ext, 3/8" wood shth, r-21 cav ins, 1/2" gypsum board int fnsh, 2"x6" wood frm, 16" o.c. stud Partitions 12F-0sw: Frm wall, 112" gyp.bd ext, r-21 cav ins, 1/2" gypsum board int fnsh, 2"x6" wood frm, 16" o.c. stud Windows 4A4-2ov'.2 glazing, clr outr, air gas, vnl frm mat, clr low-e innr, 1/4" gap, 1/4" thk; NFRC rated (SHGC=0.32); 8.5 ft head ht 4A4-2ov:2 glazing, clr outr, air gas, vnl frm mat, clr low-e innr, 1/4" gap, 1/4" thk; NFRC rated (SHGC=0.32); 9 ft head ht 4A4-2ov'. 2 glazing, clr outr, air gas, vnl frm mat, clr low-e innr, 1/4" gap, n 1l4" fhk; NFRC rated (SHGC=0.32); 14 ft head ht 4A'l-2ov: 2 glazing, clr outr, air gas, vnl frm mat, clr low-e innr, 1/4" gap, n 114" lhk; NFRC rated (SHGC=0.32); 15.83 ft head ht 4A4-2ov: 2 glazing, clr outr, air gas, vnl frm mat, clr low-e innr, 1/4" gap, n 1/4" thk; 7.83 ft head ht 1,, 10D-v:2 glazing, clr outr, air gas, vnl frm mat, clr low-e innr, '114" gap, e 1/4" thk; NFRC rated (SHGC=0.32); 6.67 ft head ht 4A4-2ov:2 glazing, clr outr, air gas, vnl frm mat, clr low-e innr, 1/4" gap, e 1/4" thk; NFRC rated (SHGC=0.32); 10 ft head ht ], 4A4-2ov:2 glazing, clr outr, air gas, vnl frm mat, clr low-e innr, 1/4" gap, s 114" lhk; NFRC rated (SHGC=O.32); 9.83 ft head ht 4A4-2ov'. 2 glazing, clr outr, air gas, vnl frm mat, clr low-e innr, 1/4" gap, s 1/4" thk; NFRC rated (SHGC=0.32); 12.25 ft head ht 0.065 0.065 0.065 0.065 0.065 3.51 4.25 4.73 3.96 4.08 3175 8387 3047 81 63 22772 0.53 0.64 0.71 0.60 0.61 478 1264 459 1230 3431 lnsul R Htg HTM Loss Clg HTM Gain ff-'F/Btuh Biuh/ff Btuh Btuh/ff Btuh 21 .0 4.81 1270 0.24 64 Or n s all Area U-value ff Btuh/fl1"F 905 1972 644 2059 5581 264 0.065 74 20 58 152 29 77 0.350 84 0.350 0 0 0 0 0 0 0 0 25.9 18 12 30 43 21 2'l 21 21 21 n e s al n 0.350 0.350 0.350 0.350 0.350 25.9 25.9 25.9 25.9 25.9 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1904 5'18 15',11 3932 738 12.4 36.4 't9.2 18.2 12.4 912 728 1117 2757 353 0.470 0.470 0.470 0.350 0.350 0.350 0.350 0.350 25.9 25.9 25.9 25.9 36.4 36.4 36.4 19.2 25.9 1994 12.4 25.9 2187 12.4 00 00 00 't123 25.5 6993 2901 9894 708 955 1047 9833 4079 't3912 524 0 0 0 05 270 112 382 27 25.9 1031 19.2 763 ..Wrightsoft HVAC\ProjectUzg9 Elk Springs Dr.rup Calc = MJB Front Door faces: N 40 0.350 ,&i{cffi d. :-g1glt-lt--,I.Rig ht-Su ite@ U niversal 2023 23.0.05 RSU60560 2024-Nou-18 15.11:29 Page 1 4A4-2ov'. 2 glazing, clr outr, air gas, vnl frm mat, clr low-e innr, 1/4" gap, s 114" lhk; NFRC rated (SHGC=0.32); 13 fi head ht 4A4-2ov'. 2 glazing, clr outr, air gas, vnl frm mat, clr low-e innr, 1/4" gap, s 1/4" thk; NFRC rated (SHGC=0.32); 8 ft head ht w 4A4-2ov 2 glazing,clr outr, air gas, vnl frm mat, clr low-e innr,1t4"S"p, :" 1/4" thk; NFRC rated (SHGC=0.32); 14.67 ft head ht 4A4-2ov'. 2 glazing, clr outr, air gas, vnl frm mat, clr low-e innr, 1/4" gap, s 1/4" thk; NFRC rated (SHGC=0.32); 19 ft head ht 4A4-2ov'. 2 glazing, clr outr, air gas, vnl frm mat, clr low-e innr, 114" gap, w 1/4" thk; 6.5 ft head ht Doors \ 11D0: Door, wd sc type 11N0: Door, ovhd mtl, eps core type Ceilings 17B-34m1: Rf/clg ceiling, mtl roof mat, wd cons, 1/2" gypsum board int fnsh, 5" thkns, r-38 ceil ins 'l8A-38md: Rf/clg ceiling, mtl roof mat, frm cons, 1/2" gypsum board int fnsh, 1 2" thkns, r-38 ceil ins Floors 19C-13cstp: Flr floor, frmllr, 12" thkns, r-13 cav ins, tight crwl ovr, r-1 1 wall insul 22B'1Otpl: Bg floor, light dry soil, on grade depth, r-10 edge ins 0.350 0.350 0.350 0.350 2s.9 25.9 25.9 25.9 19.2 36.4 29.6 19.2 193 0.350 75 115 190 94 108 0.350 45 0.470 0 0 0 0 0 0 0 25 9 4994 19.2 3694 25.9 2789 19.2 2062 0 28.9 0 2.00 1.52 0 1 930 2979 4908 2437 1 165 0 00 1427 4188 561 5 1 803 0 975 '1161 n e 40 179 2809 31 60 3727 100 0.390 0.350 o.027 0.029 0.065 0.210 8.7 34.0 38.0 24.0 10.0 352 0 0 8.72 0 s61 3 4811 0.35 0.37 1.37 5122 0.33 1225 00 0 {+wrlghtrott'Right-Suite@ U niversal 2023 23.O.05 RSU60560 2O24-Nov-18 15:'l1.29 Page2,+,{cctr ...Wrightsoft HVAC\Proiect\22g9 Elk Springs Dr.rup Calc = MJB Front Door faces: N Ji[!ffi#r ltxx. ldltr -rlt.aa2E+tn0 Gom ponent Constructions Living AHU Job: Date: By: Plan: 2299 Elk Springs Reside... Nov 15, 2024 lsaac Ross 11t06t24 ct lnformationPro For:Ek Springs Residence, Pegasus Custom Homes 2299 Elk Springs Dr., Glenwood Springs, CO 81601 Design Gonditions Location: Rifle Garfield County AP, CO, US Elevation: 6896 ftLatitude: 40'N Outdoor: Drybulb ('F) Dailyrange ("F) Wetbulb ('F) Wind speed (mph) Heating -2 15.0 Cooling 93 34 (H ) 58 7.5 lndoor: lnd oor temperature ('F) Design TD CF) Relative humidity (%) Moisture d ifference (g r/lb) lnfiltration: Method Construction quality Fireplaces Heating 72 74 30 40.1 Simplified Average 2 (Average) Cooling 75 18 50 -44.0 Construction descriptions Walls 12F-0sw: Frm wall, wd ext, 3/8" wood shth, r-21 cav ins, 1/2" gypsum board int fnsh, 2"x6" wood frm, '16" o.c. stud Partitions (none) Windows 4A4-2ov:2 glazing, clr outr, air gas, vnl frm mat, clr low-e innr, 1i4" gap, e 114" thk: NFRC rated (SHGC=0.32); 8.5 ft head ht 4A4-2ov:2 glazing, clr outr, air gas, vnl frm mat, clr low-e innr, 1/4" gap, n 1/4" thk; NFRC rated (SHGC=0.32); 9 ft head ht 4A4-2ov:2 glazing, clr outr, air gas, vnl frm mat, clr low-e innr, 1/4" gap, n 1/4" thk; NFRC rated (SHGC=0.32); 15.83 ft head ht 4A4-2ov:2 glazing, clr outr, air gas, vnl frm mat, clr low-e innr, 1/4" gap, e 1l4" lhk; NFRC rated (SHGC=0.32); 10 ft head ht w all 4A4-2ov:2 glazing, clr outr, air gas, vnl frm mat, clr low-e innr, 1/4" gap, s 114" lhk; NFRC rated (SHGC=0.32); 9.83 ft head ht 4A4-2ov:2 glazing, clr outr, air gas, vnl frm mat, clr low-e innr, 1/4" gap, s 114" lhk; NFRC rated (SHGC=0.32); 13 ft head ht 4A4-2ov: 2 glazing, clr outr, air gas, vnl frm mat, clr low-e innr, 1/4" gap, s 1/4" thk; NFRC rated (SHGC=0.32); 19 ft head ht Or Area 169 866 93 999 2127 U-value Btuh/fr1'F 0.027 0.029 Btuhtr lnsul R Htg HTM ff-"F/Btuh Btuh/ff Loss Clg HTM Gain Btuh Btuh/ff n e s all 0.065 0.065 0.065 0.065 0.065 21 .0 21 .0 21 .0 21 .0 21 .0 4.81 4.81 4.81 4.81 4.81 0.72 0.72 0.72 0.72 0.72 518 36.4 728 738 12.4 353 2187 12.4 1047 122 628 68 724 1541 192 3694 19.2 2062 811 4165 448 4805 10230 4403 2501 7304 708 4994 2789 20 29 84 0.350 0.350 0.350 0.350 0.350 0.350 0.350 0.350 0.350 25.9 25.9 25.9 25.9 25.9 25.9 25.9 25.9 25.9 0 0 0 0 0 0 0 0 0 n 170 112 282 27 193 108 40 0.390 36.4 36.4 36.4 19.2 61 91 4079 10270 524 0 28.9 1'165 8.72 Doors 11D0: Door, wd sc type Geilings 178-34m1: Rf/clg ceiling, mtl roof mat, wd cons, l12" gypsum board int fnsh, 5" thkns, r-38 ceil ins 18A-38md: Rf/clg ceiling, mtl roof mat, frm cons, 1/2" gypsum board int fnsh, 12" thkns, r-38 ceil ins 1 690 351 34.0 38.0 2.00 2.15 3377 753 0.35 0.52 352 586 182 * yyg1.1-*ort'Rig ht-Su ite@ U niv ersal 2023 23.0.05 RSUO 0560 2024-Nov-18 15:11:29 Page 3A.{cch Wrightsoft HVAC\ProjectU2gg Elk Springs Dr.rup Calc = MJ8 Front Door faces: N Floors 1 9C-1 3cstp: Flr floor, frm llr, 12" thkns, r-1 3 cav ins, tight crwl ovr, r-1 1 wall insul 1407 0.065 24.0 1 .37 1934 0.33 463 t{* :f.l*""-tty*.-*' *,sht-sun* u niversat zozs zs.o.os RSU6o56o 2024-Nov-18 15:11:29 Page 4,e ,{CCA ..Wrightsoft HVAC\Project\229g Elk Springs Dr.rup Calc = MJg Front Door faces: N ffifu llttrlrasrffiIfl Com ponent Gonstructions Bedrooms AHU Job: Date: By: Plan: 2299 Elk Springs Reside,.. Nov 15, 2024 lsaac Ross 't1t06t242'+fn0 lnformationPro For:Ek Springs Residence, Pegasus Custom Homes 2299 Elk Springs Dr., Glenwood Springs, CO 81601 Design Conditions Location: Rifle Garfield County AP, CO, US Elevation: 6896 ftLatitude: 40'NOutdoor: Heating Drybulb ('F) -2 Dailyrange ('F) Wet bulb ('F) Wind speed (mph) 15.0 lingGoo Indoor: lnd oor temperature ("F) Design TD CF) Relative humidity (%) Moisture difference (gr/lb) Infiltration: Method Construction quality Fireplaces Heating 72 74 30 40.1 Simplified Average 2 (Average) Gooling 75 18 50 -44.0 9334 (H ) 58 7.5 Construction descri ptions Walls 12F-Osw: Frm wall, wd ext, 3/8" wood shth, r-21 cav ins, l12" gypsum board int fnsh, 2"x6" wood frm, 16" o.c. stud Partitions 12F-0sw: Frm wall, 112" gyp.bd exl, r-21 cav ins, 1/2" gypsum board int fnsh, 2"x6" wood frm, 16" o.c. stud Windows 4A4-2ov'.2 glazing, clr outr, air gas, vnl frm mat, clr low-e innr, 1/4" gap, n '114" lhk: NFRC rated (SHGC=0.32); 8.5 ft head ht 1,, 4A4-2ov: 2 glazing, clr outr, air gas, vnl frm mat, clr low-e innr, 1i4" gap, n 1i4" thk; NFRC rated (SHGC=0.32); 14 ft head ht 10D-v:2 glazing, clr outr, air gas, vnl frm mat, clr low-e innr, 1/4" gap, e 114" Ihk; NFRC rated (SHGC=0.32); 6.67 ft head ht 4A4-2ov: 2 glazing, clr outr, air gas, vnl frm mat, clr low-e innr, 1/4" gap, e 1/4" thk; NFRC rated (SHGC=0.32); 10 ft head ht 4A4-2ov:2 glazing, clr outr, air gas, vnl frm mat, clr low-e innr, 1/4" gap, s 1/4" thk; NFRC rated (SHGC=0.32); 12.25ft head ht 4A4-2ov:2 glazing, clr outr, air gas, vnl frm mat, clr low-e innr, 1/4" gap, s 1/4" thk; NFRC rated (SHGC=0.32); 8 ft head ht ], 4A4-2ov:2 glazing, clr outr, air gas, vnl frm mat, clr low-e innr, 1i4" gap, s 1/4" thk; NFRC rated (SHGC=0.32); 14.67 ft head ht Doors (none) 0.065 0.065 0.065 0.065 0.065 21.0 21.0 21.0 21 .0 21 0 4.81 4.81 4.81 4.81 481 2364 4222 2599 3357 12542 0.72 0.72 0.72 0.72 0.72 356 636 392 506 1 890 492 878 540 698 2607 264 n e s all Or Area U-value ff3 Btuh/fli-"F 0.065 74 58 132 77 43 0.350 100 0.350 40 0.350 75 115 190 94 1119 0.027 lnsul R Htg HTM Loss Glg HTM Gain ft'z-'FiBtuh Btuh/fr'?Btuh Btuh/ff Btuh 21 .0 4.81 1270 0.24 64 0.350 0.350 0.350 0.350 25.9 25.9 25.9 25.9 12.4 19.2 15.4 12.4 0 0 0 0 0 0 0 0 0 0 0 1904 1511 3414 1994 912 1117 2029 955 0.350 0.350 0.350 0.350 25.9 25.9 25.9 25.5 19.2 36.4 29.6 19.2 1427 41 88 561 5 1 803 25.9 1123 25.5 1105 25.9 2590 36.4 3642 25.9 1031 19.2 763 1 930 2979 4908 2437 Ceilings 178-34m1: Rf/clg ceiling, mtl roof mat, wd cons, 112" gypsum board int fnsh, 5" thkns, r-38 ceil ins 2.00 2235 0.35 388 ,g,lCfr Wrightsoft HvAc\Project\22gg Elk Springs Dr.rup Calc = MJB Front Door faces: N 34.0 .ll|} rrrlghtroft'Rig ht-Su ite@ U niv ersal 2023 23.0.05 RSU6 0560 2024-Nov-18 15:11,29 Page 5 18A-38md; Rf/clg ceiling, mtl roof mat, frm cons, 1/2" gypsum board int fnsh, 12" thkns, r-38 ceil ins Floors 19C-13cstp: Flr floor, frmflr, 12" thkns, r-13 cav ins, tight crwl ovr, r-1 1 wall insul 1891 0.029 2320 0.065 38.0 2.'t5 4058 0.52 979 24.0 't .37 3188 0.33 763 {+ ltrL?,ltgtjf Ris hr-su ite@ u niv ersar zozs zs.o.o5 Rsu6 0560 2024-Nov-18 15:11:29,+/$Ch ...Wrightsoft HVAC\Project\22g9 Elk Springs Dr.rup Calc = MJ8 Front Door faces: N Page 6 rytulllllr!fitHltll Gom ponent Constructions Garage Job; Date: By: Plan: 2299 Elk Springs Reside... Nov 15,2024 lsaac Ross 11t06t242EGtft0 ect lnformationPro For:Ek Springs Residence, Pegasus Custom Homes 2299 Elk Springs Dr., Glenwood Springs, CO 81601 Design Gonditions Location: Rifle Garfield County AP, CO, US Elevation: 6896 ftLatitude: 40'N Outdoor: Drybulb ('F) Dailyrange ("F) Wetbulb ('F) Wind speed (mph) Heating -2 15.0 Gooling 93 34 (H ) 58 7.5 lndoor: lndoor temperature ('F) Design TD fF) Relative humidity (%) Moisture difference (gr/lb) lnfiltration: Method Construction quality Fireplaces Heating 72 74 30 40.1 Simplified Average 2 (Average) Cooling 75 18 50 -44.0 Construction descriptions Walls 12F-0sw: Frm wall, wd ext, 3/8" wood shth, r-21 cav ins, l12" gypsum board int fnsh, 2"x6" wood frm, 16" o.c. stud Partitions (none) Windows 4A4-2ov: 2 glazing, clr outr, air gas, vnl frm mat, clr low-e innr, 1/4" gap, n 114" lhk;7.83 ft head ht n all 4A4-2ov: 2 glazing, clr outr, air gas, vnl frm mat, clr low-e innr, 1/4" gap, w 1/4" thk; 6.5 ft head ht Doors 11N0: Door, ovhd mtl, eps core type Or Area 245 229 11 362 847 U-value Btuh/ff-'Fffa lnsul R Htg HTM Loss Clg HTM Gain fla"F/Bluh Btuh/ff Btuh Btuh/ff Biuh 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 n e s all 0.065 0.065 0.065 0.065 0.065 21 .O 21 .O 21.0 21.0 21.0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 18 12 30 45 0.470 o 470 o 470 0.470 0 0 0 0 0 0 0 0 e 179 0.350 8.7 38.0 10.0 0 0 00 00 00 0 0 Ceilings 18A-38md: Rf/clg ceiling, mtl roof mat, frm cons, 1/2" gypsum board int fnsh, 12" thkns, r-38 ceil ins 918 0.029 100 0.210 FIoors 22B-10tpl: Bg floor, light dry soil, on grade depth, r-10 edge ins 0 .{*wrlgfrtroft'Right-Suite@ U niversal 2023 23.0.05 RSU60560 2024-Nov-18 15:11:29 Page 7,e,{CCtr ...Wrightsoft HvAc\Project\22gg Elk Springs Dr.rup Calc = MJ8 Front Door faces: N llfrrlllr-thltI 1[&fl?0 Project Summary Entire House Job: Date: By: Plan: 2299 Elk Springs Reside... Nov't5,2024 lsaac Ross 11t06t24 For: Notes: Ek Sorinos Residence. Peoasus Custom Homes ZZgg etk"Springs Dr., Gleriwood Springs, CO 81601 n lnformationDesi Outside db lnside db Design TD Structure Weather: Winter Design Gonditions Rifle Garfield County AP, CO, US Outside db lnside db Design TD Daily range Relative humiditv Moisture differerice Summer Design Conditions -2 "F72 "F74 "F 99977 Btuh 20703 Btuh0 Btuh 0 Btuh0 Btuh 120680 Btuh 50271 Btuh 1 1700 Btuh0 Btuh 93 'F75 "F18'F H 5O Yo-44 grllb Heating Summary Sensible Gooling Equipment Load Sizing Ducts (R-6.0) Central vent (0 cfm) Humidification Piping Equipment load Method Construction quality Fireplaces Area (ftz) Volume (ff) Air chan!e's/hour Equiv. AVF (cfm) Make Trade Model AHRI ref nla nla nla nla Efficiency Heatino inout Heatin! output Temoerature rise Actubl air flow Air flow factor Static pressure Space thermostat lnfiltration Structure Ducts (R-6.0) Central vent (0 cfm) Blower Use manufacturer's data Rate/swing multiplier Equipment sensible load Equipment latent load Equipment Total Load Req. total capacity at 0. Make nlaTrade nlaCond nlaCoil nla AHRI ref nla Efficiency Sensible cooling Latent cooling Total coolino Actual air fldw Air flow factor Static pressure Load sensible heat ratio 0 Btuh n 0.98 60546 Btuh 0 Btuh 60546 Btuh 7.2 lon Simplified Averaoe 2 (Averag"e) Heatinq Coolino372f 3727 Latent Cooling Equipment Load Sizing Structure -3865 BtuhDucts -1309 Btuh Centralvent (0 cfm) 0 Btuh 51346 0.31 267 51 346 0.15 128 (Sen+Lat) 70 SHR Heating Equipment Summary Cooling Equipment Summary 0 Btuh0'F0 cfm0 cfm/Btuh0 in H2O nla 0 0 0 0 0 0 0 nla Btu Btu Btu cfm h h h cfm/Btu in H2O h nla Boldlitalic values have been manually oveffidden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed 2024-Nov-18 15:11:29 Page 1€ ,/lCCr....Wrightsoft HVAC\ProjectU2gg Elk Springs Dr.rup Calc = MJB Front Door faces: N ffi B!?,?"J,;JTfffr" til+ltt0 Job: Date: By: Plan: 2299 Elk Springs Reside... Nov 15, 2024 lsaac Ross 11t06t24 lnformatioPro For: Notes Ek Sorinos Residence. Peoasus Custom Homes ZZgg ett"springs Dr., Glen\uood Springs, CO 81601 I rm n Weather: Winter Design Conditions Rifle Garfield County AP, CO, US Summer Design Conditions Outside db lnside db Desion TD Daily"range Relative humiditv Moisture differedce Sensible Gooling Equipment Load Sizing Structure Ducts (R-6.0) Central vent (0 cfm) (none) Blower Use manufacturer's data Rate/swing multiplier Equipment sensible load Outside db lnside db Design TD Structure Make Trade Model AHRI ref Heating Summary -2'F72 "F74 'F 53487 Btuh 10216 Btuh0 Btuh 0 Btuh0 Btuh 63703 Btuh 93 "F75 "F 18 'F H 50 o/o -44 grllb Ducts (R-6.0) Central vent (0 cfm) (none) Humidification Piping Equipment load Method Construction quality Fireplaces lnfiltration OF cfm cfm/Btuh in H2O Botdlitalic values have been manually overridden 24646 Btuh 6269 Btuh0 Btuh 1707 Btuh Latent Cooling Equipment Load Sizing Structure Ducts Centralvent (0 cfm) (none) eqdipmeht latent load Equipment Total Load (Sen+Lat) 31871 Btuh Req. totalcapacity at 0.70 SHR 3.8 ton Cooling Equipment Summary Make LennoxTrade LENNOXCond ML18XC2-048-230A**Coil CK40DT-50/60C-01 AHRI refEfficiency 12.5 EER2,15.2 SEER2 Sensible coolino 32550 Btuh Latentcooling - 13950 BtuhTotalcoolino 46500 Btuh Actualair fldw 1400 cfm Air flow factor 0.043 cfm/Btuh Static pressure 0 in H2O Load sensible heat ratio 1.00 n 0.98 31871 Btuh -778 Btuh -642 Btuh0 Btuh 0 Btuh Simplified Averaoe 2 (Averag-e) Heatinq Coolinq Area (ft'?) 232t 2320- Volume (ff) 30589 30589 Air change's/hour 0.28 0.13 Equiv. AVF (cfm) 141 68 Heating Equipment Summary Lennox LENNOX EL297DF1 10XV60C-. Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 97 AFUE 110000 Btuh 80256 Btuh 67 1400 0.022 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed {+ y,:!p,t"tt:-!!:RighFSuite@ U niversal 2023 23.0.05 RSU60560 2024-Nov-18 15:11:29 Page2^+./aCCh....Wrightsoft HVAC\Project\2299 Elk Springs Dr.rup Calc = MJ8 Front Door faces: N ffi "i3l:;\?.,ifmary 1$f-ttto Job: Date: By: Plan: 2299 Elk Springs Reside,.. Nov 15,2024 lsaac Ross 'l'1106124 ect InformationPro For: Notes: Ek Sorinos Residence. Peoasus Custom Homes 2299 Elkbprings Dr., Gleniwood Springs, CO 81601 Weather: Rifle Garfield County AP, CO, US Winter Design Gonditions -2 Heating Summary Summer Design Conditions Outside db lnside db Design TD Structure Make Trade Model AHRI ref Ducts (R-6.0) Central vent (0 cfm) (none) Huri'ridification Pioino Equip-"ment load Method Construction quality Fireplaces Area (ft'z) Volume (ff) Air changes/hour Equiv. AVF (cfm) 46489 Btuh 10487 Btuh0 Btuh 72 74 Btuh 0 0 56977 93 'F75 'F 18 "F H 50% -44 grllb OF OF OF Btuh Btuh Outside db lnside db Desion TD Daily"range Relative humiditv Moisture differerice Structure Ducts (R-6.0) Centralvent (0 cfm) (none) Blower Use manufacturer's data Sensible Cooling Equipment Load Sizing lnfiltration Rate/swino multiolier Equipmenl sensible load Latent Cooling Equipment Load Sizing Structure -1695 BtuhDucts -667 Btuh Centralvent (0 cfm) 0 Btuh (none) eqdipmeht latent load 0 Btuh Equipment Total Load (Sen+Lat) Req. totalcapacity at 0.70 SHR 25625 Btuh 5403 Btuh0 Btuh 1707 Btuh n 0.98 31981 Btuh 31981 Btuh 3.8 ton 13.0 EER2,15.2 SEER2 32550 Btuh 13950 Btuh Simplified Averaoe 2 (Averag"e) "",,"l'dP Heatino 140r 20757 0.36 125 Heating Equipment Summary Lennox LENNOX EL297DF090XV60C-* 20757 0.17 60 97 AFUE 88000 Btuh 64204 Btuh 47 "F'1600 cfm 0.028 cfm/Btuh0 in H2O Make Trade Cond Coil AHRIref Gooling Equipment Summary Lennox LENNOX ML18XC2-048-2304** cK40DT-50/60C-01 Efficiency Heating input Heating output Temoerature rise Actubl air flow Air flow factor Static pressure Space thermostat Efficiency Sensible coolino Latent cooling " Total coolino Actual air fldw Air flow factor Static pressure 46500 Btuh 1600 cfm 0.052 cfm/Btuh0 in H2O 1.00Load sensible heat ratio Boldlitalic values have heen manualty ovefiidden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. d* raerlaht*ott'' '-;*: -="--'* --; Right-Suite@ Universal 202323.0.05 RSU60560 2024-Nov-18 15:11:29 Page 3*,-,€6...Wrightsoft HVAC\ProjectU2gg Elk Springs Dr.rup Calc = MJ8 Front Door faces: N JiEon[ fiHlHllllttrrtrn AED Assessment Entire House 26+ilr0 Job: Date: By: Plan: 2299 Elk Springs Reside... Nov 15, 2024 lsaac Ross 11t06t24 Project lnformation For:Ek Springs Residence, Pegasus Custom Homes 2299 Elk Springs Dr., Glenwood Springs, CO 81601 Design Conditions Location: Rifle Garfield County AP, CO, US Elevation: 6896 ftLatitude: 40"N Outdoor: Drybulb ("F) Dailyrange ("F) Wetbulb ("F) Wind speed (mph) oolingc lndoor: lndoor temperature ('F) Design TD CF) Relative humidity (%) Moisture difference (gr/lb) lnfiltration: Heating 72 74 30 40.1 Cooling 75 18 50 -44.0Heating -2 15.0 9334 (H ) 58 7.5 Test for Adequate Exposure Diversity Fh.rlyGaziryld tuofDay 5, 0 402 / AED limil Maximum hourly glazing load exceeds average by 24.3%. House has adequate exposure diversity (AED), based on AED limit of 30%. AED excursion: 0 Btuh Botdlitatic values have been manuatly ovenidden tl* 31rteL.-l'*,91;Rig ht-Su ite@ U niversal 2023 23.0.O5 RSU60560 2024-Nov-18 15:11:29 Page 1,5 ,1CCtr Wrightsoft HvAc\Project\z2gg Elk Springs Dr.rup Calc = MJ8 Front Door faces: N Irfl AED Assessment Bedrooms AHU Job: 2299 Elk Springs Reside... Date: Nov'15,2024 By: lsaac Ross Plan: 11106124 ect lnformationPro For:Ek Springs Residence, Pegasus Custom Homes 2299Elk Springs Dr., Glenwood Springs, CO 81601 Design Gonditions Location: Rifle Garfield County AP, CO, US Elevation: 6896 ftLatitude: 40'N Outdoor: Drybulb ("F) Dailyrange ("F) Wetbulb ("F) Wind speed (mph) lndoor: lnd oor temperature ("F) Design TD ("F) Relative humidity (%) Moisture difference (gr/lb) lnfiltration: Heating 72 74 30 40.1 75 18 50 -44.0 Cooling Heating -2 15.0 93 34 (H ) 58 7.5 lingCoo Test for Adequate Exposure Divers FtulyClzing t oad 20, 18, 16, 14, 0 I Flour cfDay / AEDlimil Maximum hourly glazing load exceeds average by 25.5o/o. Zone has adequate exposure diversity (AED), based on AED limit of 30%. AED excursion: 0 Btuh Boldlitalic values have been manuatly ovenidden tl* :t:lgl*P-If *,s n."u ire@ u niversat zozs zz.o.osRSU60o60 2024-Nov-18 15:11:29,g ,{CCl'...Wrightsoft HvAc\Project\22gg Elk Springs Dr.rup Calc = MJ8 Front Door faces: N Page2 r.rrr!.lrrarllll1 AED Assessment Living AHU r6+ilr0 Job: Date: By: Plan: 2299 Elk Springs Reside... Nov 15, 2024 lsaac Ross 11t06t24 Project lnformation For:Ek Springs Residence, Pegasus Custom Homes 2299 Elk Springs Dr., Glenwood Springs, CO 81601 Design Conditions Location: Rifle Garfield County AP, CO, US Elevation: 6896 ftLatitude: 40'NOutdoor: Heating Drybulb ('F) -2 Dailyrange ('F) Wetbulb ('F) Wind speed (mph) 15.0 Cooling 93 34 (H ) 58 lndoor: lndoor temperature ('F) Design TD CF) Relative humidity (%) Moisture difference (gr/lb) lnfiltration: Heating 72 74 30 40.1 Cooling 75 18 50 -44.0 7.5 Test for Adequate Exposure Diversity l-b,rV Glziru t od 0 8 Flou ofDay / AEDlimil Maximum hourly glazing load exceeds average by 24.0%. Zone has adequate exposure diversity (AED), based on AED limit of 30%. AED excursion: 0 Btuh Boldlitalic values have been manualty overridden df uvrlolrtrofit'I .;;; ,=-.^;;4.;..; Right-Suite@ Universal 202323.0.05 RSU60560 2024-Nov-1I 15,'lI:29 Page 3,glcctr ..Wrightsoft HvAc\Project\z2gg Elk Springs Dr.rup Calc = MJ8 Front Door faces: N Ji[lofrdr 4..-ra..hlhr- Right-J@ Worksheet Entire House Job: Date: 2299 Elk Springs Residence Nov 15, 2024 lsaac Ross 11t06t24 8$+flT0 Bv: Plan I 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area Entire House 470.0 ft 13,2 ft 4645.0 ft' Living AHU 130.0 ft't4.8 ft 1407.0 il2 Ty Construction number U-value (Bt uh/ft'?-'F Or HTM (Bt uh/ft') Area (ft') perimeter (ft)or Load (Btuh) Area (f t')or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool b 'l W L----G L----G L---G L---G L--.c L-.Glo Wl--ct^l_clO Wl-Gl+l-Gl-.cl_c L----clC W L-----G L----€lc P c c F F 12F-0sw 444-2ov 444-2ov 444-2ov 444-zov 4A4-2ov 444-?ov 11D0 12F-osw 10D-v 444-2ou 444-zou 11N0 12F-osw 444-zov 444-2ou 4A.4-2ou 444-zov 444-zov 444-2ov 444-2ou 12F-0sw 444-2ou 444-2ov 444-2ov 12F-0sw 178-34ml, 18A-38md 19C-13cstp 22F'Jt0tpl 0.065 0.350 0.350 0.350 0.350 0.470 0.470 0.390 0.065 0.350 0.350 0.350 0.350 0.065 0.350 0.350 0.350 0.350 0.350 0.350 0.350 0.065 0.350 0.350 0.470 0.065 0.027 0.029 0.065 o.210 3.51 25.90 25.90 25.90 25.90 0.00 0.00 28.86 4.25 25.90 25.90 25.90 0.00 4.73 25.90 25.90 25.90 25-90 25.90 25.90 25.90 3.96 25.90 25.90 0.00 4.81 2.00 1.52 1.37 0.00 0.53 12.40 12.40 12.40 12.40 0.00 0.00 8.72 0.64 25.49 36.42 36.42 0.00 0.71 19.15 19.1 5 19.1 5 19.'t5 19.1 5 19.1 5 19.15 0.60 36.42 36.42 0.00 0.24 0.35 0.37 0.33 0.00 1239 74 29 77 84 18 12 40 2484 43 270 20 179 1239 27 58 40 193 75 94 108 2331 112 115 45 264 2809 3160 3727 918 905 0 0 0 0 0 0 40 1972 0 0 0 179 644 0 0 0 0 0 0 2059 0 0 0 264 2809 3160 3727 100 3175 1904 738 1994 2187 0 0 1 165 8387 1123 6993 518 0 3047 708 1511 1031 4994 1930 2437 2789 8163 2901 2978 0 1270 561 3 4811 5'122 0 478 912 353 955 1047 0 0 352 '1264 1 105 9833 728 0 459 524 1 11i 763 3694 1427 1 803 2062 1230 4079 41 88 n 64 975 1161 1225 0 322 0 29 0 84 0 0 40 1 056 0 170 20 0 421 27 0 0 193 0 0 108 11't 112 0 0 1 690 351 1407 0 169 0 0 0 0 0 0 40 doo 0 0 0 0 93 0 0 0 0 0 0 U 999 0 0 0 0 1 690 351 1407 0 81'l 0 738 0 2'187 0 0 1 165 4165 0 4403 5'18 0 448 708 0 4994 0 0 2789 4805 2901 0 0 0 JJI I 753 1934 0 122 0 353 0 1047 0 0 352 628 0 61 91 728 0 68 524 0 0 3694 0 0 2062 724 4079 0 0 0 586 182 463 0 6 c) AED excursion 0 0 Envelope loss/gain 77489 41797 36698 21803 12 a) Infiltration b) Room ventilation 16812 5675 1 936 1357 7900 1892 910 452 13 lnternal gains:Occupants @ Appliances/other 230 6 1 380 3800 460 2000 Subtotal (lines 6 to 1 3)99977 50271 46489 25625 1 1 4 5 Less external load Less transfer Redistribution Subtotal Duct loads 21%o 24o/o 0 0 0 99977 20703 0 0 0 50271 1170Q 23o/o 21o/o 0 0 0 46489 10487 0 0 0 25625 5403 Total room load Air required (cfm) 120680 3000 61971 331 1 56977 '1600 31028 1600 Calculations aooroved bv ACCA to ^*^ all reorriremenfs of Manual .l 8th Ecl {{J- wrloht3oft-'7 '- '- Right-Suite@ u niversal 2023 23.0.05 RSU60560 ...Wrightsoft HvAc\Project\2zg9 Elk Springs Dr.rup Calc = MJ8 Front Door faces: N 2024-Nou-18 15:11.29 Page 1 IrtPnsqfu m.a.Llltrb Right-J@ Worksheet Entire House Job: Date: 2299 Elk Springs Residence Nov 15,2024 lsaac Ross 11t06r24 t5+flilt Bv: Pfan 1 2 J 4 5 Room name Exposed wall Room height Room dimensions Room area Bedrooms AHU 240.0 ft 13.2 ft 2320.0 lt2 Unconditioned Gar 100,0 ft 11.0 ft 918.0 ft, Ty Construction number U-value (Bt uh/ft4'F Or HTM (Bt uh/ft') Area (f t')or perimeter (ft) Load (Btuh) Area (ft')or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool o 1 1 WL--G L--G t----c L----G L----c L----clo WL--r; t----G l------clo WlG t---c l-----€ L----c L----c L---ct^ vy l+t--€lC P c F F 12F-0sw 444-2ov 444-2ov 444-2ou 444-2ou 444-2ov 444-2ou 1 1D0 12F-osw 10D-v 444-2ov 444-2ov 11N0 12F-osw 444-2ov 444-2ov 4A.4-2ov 4A4-?ov 4I.4-zou 444-2ou 444-2ou 1 2F-Osw 444-zov 444-2ov 444-2ov 12F-0sw 178-34m1 18A-38md 1 9C-1 3cstD 22B'-1Otpl 0.065 0.350 0.350 0.350 0.350 0.470 0.470 0.390 0.065 0.350 0.350 0.350 0.350 0.065 0.350 0.350 0.350 0.350 0.350 0.350 0.350 0.065 0.350 0.350 o.470 0.065 0.027 0.029 0.065 0.210 n n n n n n n n e s s s s s s s s Y 3.5'l 25.90 25.90 25.90 25.90 0.00 0.00 28.86 4.25 25.90 25.90 25.90 0.00 4.73 25.90 25.90 25.90 25.90 25.90 25.90 25.90 3.96 25.90 25.90 0.00 4.81 2.00 1.52 1.37 0.00 0.53 12.40 12.40 12.40 '12.40 0.00 0.00 8.72 0.64 25.49 36.42 36.42 0.00 0.71 '19.15 19.15 19.15 19.15 19.15 19.15 19.15 0.60 36.42 36.42 0.00 0.24 0.35 0.37 0.33 0.00 642 74 0 77 0 0 0 0 1021 43 100 0 0 807 0 58 40 0 75 94 0 813 0 115 0 264 't't19 1891 2320 0 492 0 0 0 0 0 0 0 878 0 0 U 0 540 0 0 0 0 0 0 0 698 0 0 0 264 11 19 1 891 2320 0 2364 1904 U 1994 U 0 0 0 4222 1123 2590 0 0 2599 0 1511 1 031 0 1 930 2437 0 3357 0 2978 0 1270 2235 4058 31 88 0 356 912 0 955 0 0 0 0 oJo 1 105 3642 0 0 392 0 1117 763 0 1427 1 803 0 506 0 41 88 0 64 388 979 763 0 275 0 0 0 0 18 12 0 407 0 0 0 179 11 0 0 0 0 0 0 0 407 0 45 0 0 9t8 0 918 245 0 0 0 0 0 0 0 229 0 0 0 179 11 U 0 0 0 0 0 0 362 0 0 0 0 0 918 0 100 0 0 0 0 0 0 U 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 U 0 0 0 0 0 0 0 0 0 U 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 6 c) AED excursion 0 0 Envelope loss/gain 40791 19995 U 0 12 a) b) lnfiltration Room ventilation 891 3 3784 1026 905 0 0 0 0 13 lnternal gains:Occupants @ Appliances/other 230 4 920 1 800 0 0 0 Subtotal (lines 6 to 13)53487 24646 0 0 1 I 4 5 Less external load Less transfer Redistribution Subtotal Duct loads 19o/o 27o/o 0 0 U 53487 10216 0 0 0 24646 6269 0v"0o/. 0 0 0 0 0 0 0 0 0 0 Total room load Air required (cfm) 63703 1400 3091 5 1400 0 0 0 0 Calculations aooroved bv ACCA to frr all renuiremenls of Manual .l 8th Fd Page2 4{J- wrtoht-oft-'- ' ' Right-Suite@ Universal 202323.0.05 RSU60560 ...Wrightsoft HvAc\Project\2zgg Elk Springs Dr.rup Calc - MJ8 Front Door faces: N 2024-Nov-18 15:11:29 JrEpft# lrt..taIHI- ts+fl?0 Right-J@ Worksheet Bedrooms AHU Job: Date: 2299 Elk Springs Residence Nov 15,2024 lsaac Ross 11t06t24 Bv: P[an: 1 2 4 6 Room name Exposed wall Room height Room dimensions Room area Bedrooms AHU 240.0 ft 13.2 ft 2320.0 ft2 Bed 1-2 Zone 126.0 ft 13.1 ft 1261.0 tt' Ty Construction number U-value (Bt uh/fta'F Or HTM (Bt uh/ft') Area (ft" )perimeter (ft)or Load (Btuh) Area (fr') perimeier (ft)or Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Gool b 1 1 Wl--c L---cL--€ L---G L----G t----clo WL--J; L----ct---cL-D WL-GL+ l-----c L---c l-----c L----€lC W L----c l-----clC P c c F F 12F-osw 444-2ou 444-2ov 444-2ou 444-2ov 444-2ov 444-2ov 11D0 1 2F-0sw 1oD-v 444-2ov 4A.4-2ov 1 1N0 'l2F-osw 444-zov 444-2ov 444-2ov 444-zov 444-2ov 444-2ov 444-2ov 12F-0sw 444-2ou 444-2ou 444-2ou 12F-osw 1 7B-34m1 18A-38md '19C-13cstp 22B.10lpl 0.065 0.350 0.350 0.350 0.350 0.470 0.470 0.390 0.065 0.350 0.350 0.350 0.350 0.065 0.350 0.350 0.350 0.350 0.350 0.350 0.350 0.065 0.350 0.350 0,470 0.065 0.027 0.029 0.065 0.210 4.81 25.90 0.00 25.90 0.00 0.00 0.00 0.00 4.81 25.90 25.90 0.00 0.00 4.8'l 0.00 25.90 25.90 0.00 25.90 25.90 0.00 4.81 0.00 25.90 0.00 4.81 2.00 2.'t5 1 .37 0.00 0.72 12.40 0.00 12.40 0.00 0.00 0.00 0.00 0.72 25.49 36.42 0.00 0.00 0.72 0.00 19.15 19.15 0.00 19.15 19.15 0.00 0.72 0.00 36.42 0.00 0.24 0.35 o.52 0.33 0.00 642 74 0 77 0 0 0 0 1021 43 100 0 0 807 0 58 40 0 75 94 0 813 0 115 0 264 111F 1891 2320 0 492 0 0 0 0 0 0 0 878 0 0 0 0 540 0 0 0 0 0 0 0 698 0 0 0 264 '111! 1891 2320 0 2364 1 904 0 1994 0 0 0 0 4222 1123 2590 0 0 2599 0 1511 '1031 0 1 930 2437 0 3357 0 2978 0 1270 zzJa 4058 31 88 0 356 I't2 0 955 0 0 0 0 oJo 1 105 3642 0 0 392 0 1117 763 0 1427 1 803 0 506 0 4188 0 64 388 979 763 0 246 53 0 0 0 0 0 0 307 0 0 0 0 411 0 23 0 0 75 0 0 429 0 264 269 1516 1261 0 193 0 0 0 0 0 0 0 307 0 U 0 0 313 0 0 0 0 0 U 0 314 0 0 0 264 269 1 516 1261 0 928 1360 0 0 0 0 0 0 1477 0 0 0 0 1504 0 604 0 ,0 1930 0 0 1 510 0 2978 0 1270 537 3253 1733 0 140 651 0 0 0 0 0 0 222 0 0 0 0 227 0 447 0 0 1427 0 0 228 0 41 88 0 64 93 785 415 0 6 c) AED excursion 0 3379 Envelope loss/gain 4079'l I OOO4 19085 12266 12 a) lnfiltration b) Room ventilation 891 3 3784 1026 905 3779 1892 435 452 IJ lnternal gains:Occupants @ Appliances/other 230 4 920 1 800 460 900 Subtotal (lines 6 to 1 3)53487 24646 24755 14514 14 15 Less external load Less transfer Redistribution Sublotal Duct loads 19Yo 27o/o 0 0 53487 10216 0 0 0 24646 6269 23o/o 29o/o 0 0 0 24755 5778 0 0 0 14514 4210 Total room load Air required (cfm) 63703 '1400 3091 5 1400 30534 67'l 18723 805 Calculations aooroved bv ACCA to ,*" all reorriremenls of Manrral .l 8lh F.l Page 3 -dJ- wrlolrt-oft-' Right-Suite@ U niversal 2023 23.0.05 RSU60560 ...Wrightsoft HvAc\Project\22gg Elk Springs Dr.rup Calc = MJ8 Front Door faces: N 2024-Nov-18 15:11:29 JatPffi*r l.rtrarl.lbrllt$+uilt Right-J@ Worksheet Bedrooms AHU Job: Date 22SS Elk Springs Residence Nov 15, 2024 lsaac Ross 't1to6t24 Bv: P[an: 1 2 4 Room name Exposed wall Room height Room dimensions Room area Master Zone '114.O ft 13.3 fr 1059.0 fr Ty Construction number U-value (Bt uh/ft4 " F Or HTM (Bt uh/ft'z) Area (f t, )or perimeter (ft) Load (Btuh) Areaor perimeter Load Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 'l 1 WL--G L---€ L----c L----c t----G L---Glo W t----c l-----c l-----clo WL--G t---€ l-----c L---G t----G L-----clC W L-----c L---€lC P c c F F 12F-0sw 444-2ov 444-2ov 444-2ov 444-2ov 444-2ou 4A.4-zou 11D0 12F-osw 1oD-v 444-2ov 4A.4-2ov 1 1N0 1 2F-osw 444-2ov 4A.4-2ov 4F.4-2ov 4F,4-2ov 4A.4-2ov 4F.4-2ov 4A.4-2ov 12F-0sw 444-2ov 444-2ov 444-2ov 'l2F-0sw 178-34m1 184-38md 'l9C-13cstp 228-1otpl 0.065 0.350 0.350 0.350 0.350 0.470 0.470 0.390 0.065 0.350 0.350 0.350 0.350 0.065 0.350 0.350 0.350 0.350 0.350 0.350 0.350 0.065 0.350 0.350 0.470 0.065 0.027 0.029 0.065 o.210 4.81 25.90 0.00 25.90 0.00 0.00 0.00 0.00 4.81 25.90 25.90 0.00 0.00 4.81 0.00 25.90 25.90 0.00 25.90 25.90 0.00 4.81 0.00 25.90 0.00 4.81 2.00 2.15 '1.37 0.00 0.72 12.40 0.00 12.40 0.00 0.00 0.00 0_00 0.72 25.49 36.42 U.UU 0.00 o.72 0.00 19.15 19.15 0.00 19.15 19.15 0.00 0.72 0.00 36.42 0.00 0.24 0.35 0.52 0.33 0.00 397 2'l 0 77 0 0 0 0 714 43 100 0 0 397 0 35 40 U 0 94 0 384 0 0 0 0 850 375 1 059 0 too 0 0 0 0 0 0 0 571 U 0 0 0 228 0 0 0 0 U U 0 384 0 0 0 0 850 375 1 059 0 1436 544 0 1994 0 0 0 0 2745 1123 2590 0 0 1095 0 906 1 031 0 0 2437 0 1847 0 0 0 0 1698 805 1455 0 216 260 0 955 0 0 0 0 414 1 '105 3642 0 n 165 n 670 763 0 0 1 803 0 278 U U 0 0 295 194 348 0 6 c) AED excursion 3764 Envelope loss/gain 2't706 14872 '12 a) lnfiltration b) Room ventilation 5134 1892 591 452 IJ lnternal gains:Occupants @ Appliances/other 230 460 900 Subtotal (lines 6 to 1 3)28732 17275 14 15 Less external Ioad Less transfer Redistribution Subtotal Duct loads 15o/o 22o/o 0 0 0 28732 4438 0 0 0 17275 3825 Total room load Air required (cfm) 33169 729 2110C 907 Calculations approved bv ACCA to ^#" all reorrirements of Manrral .l 8th Fd -t{a- wrldlrt-oft-' " " - "' Right-suite@ Universal 202323.0.05 RSU60560 ...Wrightsoft HVAC\ProjectU2gg Elk Springs Dr.rup Calc = MJB Front Door faces: N 2024-Nov-18 15:11:29 Page 4 ,| 2 J 4 Room name Exposed wall Room height Room dimensions Room area Living AHU 130.0 ft 14.8 ft 1407.O tt2 Kitch/living Zone 130.0 ft heaUcool 1.0 x 1407.0 ft 14.8 ft 1407.0 ft2 Ty Construction number U-value (Bt uh/ftL'F Or HTM (Bt uh/ft'z) Area (f r)or perimeler (ft) Load (Btuh) Area (ft')or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool o 1 1 WL--G L---c L----€ L----c t----cL--Glo W L---c t----.c l----clo Wl-.Gl< t----c L----6 L----€ L-----clc W L-----G t----clC P c c F F 12F-osw 444-2ov 444-2ov 444-2ov 4F.4-2ov 4A.4-2ov 444-2ov tlD0 '12F-osw 10D-v 444-2ov 444-2ov 1 1N0 12F-osw 4p.4-2ov 444-2ov 444-2ov 444-2ov 444-2ov 444-zov 444-2ov 12F-0sw 444-2ou 444-2ou 444-2ov 12F-Osw 178-34m1 18A-38md 1 9C-1 3cstD 228-10tpl 0.065 0.350 0.350 0.350 0.350 0.470 0.470 0.390 0.065 0.350 0.350 0.350 0.350 0.065 0.350 0.350 0.350 0.350 0.350 0.350 0.350 0.065 0.350 0.350 0,470 0.065 0.027 0.029 0.065 0.2'10 4.81 0.00 25.90 0.00 25.90 0.00 0.00 28.86 4.81 0.00 25.90 25.90 0.00 4.81 25.90 0.00 0.00 25.90 0.00 0.00 25.90 4.81 25.90 0.00 0.00 0.00 2.00 2.15 1.37 0.00 0.72 0.00 12.40 0.00 12.40 0.00 0.00 8.72 0.72 0.00 36.42 36.42 0.00 0.72 19.1 5 0.00 0.00 19.'15 0.00 0.00 19.'t 5 0.72 36.42 0.00 0.00 0.00 0.35 0.52 0.33 0.00 322 0 29 0 84 0 0 40 1 056 U 't70 20 0 42',1 27 0 0 193 0 0 108 111i 112 0 0 0 1690 351 1407 0 '169 0 0 0 0 0 0 40 866 0 0 0 0 93 0 0 0 0 0 U 0 ooo 0 0 0 0 1 690 351 1407 0 811 0 738 0 2187 0 0 1 165 4165 n 4403 518 0 448 708 0 0 4994 n n 2789 4805 290'l 0 0 0 3377 753 1934 0 122 0 353 0 1047 0 0 352 628 0 61 91 728 0 68 524 0 0 3694 0 U 2062 724 4079 0 0 0 586 182 463 0 322 0 29 0 84 0 0 40 1 056 0 170 20 0 421 27 0 0 193 0 0 108 111' '112 U U 0 1690 351 1407 0 169 0 0 0 0 0 0 40 ooo 0 0 0 0 93 0 0 0 0 0 0 0 999 0 0 0 0 1690 351 1407 0 811 0 738 0 2187 0 0 1 165 4165 0 4403 5'18 0 448 708 0 0 4994 0 0 2789 4805 2901 U U 0 3377 753 1 934 0 122 0 353 0 1047 0 n 352 628 0 61 91 728 0 68 524 0 0 3694 0 0 2062 724 4079 0 0 U 586 182 463 0 c) AED excursion 0 0 Envelope loss/gain 36698 21 803 36698 21803 12 a) lnfiltration b) Room ventilation 7900 1892 910 452 7900 1892 910 452 IJ lnternal gains:Occupants @ Appliances/other 230 2 460 2000 460 2000 Subtotal (lines 6 to 1 3)46489 25625 46489 25625 I 1 4 5 Less external load Less transfer Redistribution Subtotal Duct loads 23%21o/o 0 0 0 46489 10487 0 0 0 25625 5403 23Yo 21o/o 0 0 0 46489 10487 0 0 0 25625 5403 Total room load Air required (cfm) 56977 1600 31028 1 600 56977 1600 31 028 1 600 Jtilen[ #rrL.brkhlllrBtE+flt0 Right-J@ Worksheet Living AHU Job: Date: 2299 Elk Springs Residence Nov 15, 2024 lsaac Ross 11t06t24 Bv: P[an Calculations aoDroved bv ACCA to meet all requirements of Manual J 8th Ed. ^#^ -dJ- wraotrt-oft-' " 7 ' ' - Rig ht-Su ite@ U niv ersal 2023 23 .0.05 RSU6 0560 ...Wrightsoft HvAc\Project\22gg Elk Springs Dr.rup Galc = MJ8 Front Door faces: N 2024-Nou-18 15:11.29 Page 5