HomeMy WebLinkAboutConditions of PermitCOND ITIO NS OF PERMIT BLCO-12-24-9012 GARCO PREMIER HANGERS ADDING A RESTROOM WITHIN THE HANGER GARFIELD COU NTY AIRPORT _ 375 CR 225 1) THE APPROVED PLANS ARE TO BE ON-SlrE FOR INSPECTIONS. 2) SANTTARY FACILITIES ARE REOUIRED TO BE PROVIDED FOR WORKERS. 3) A LIST OF REOUIRED INSPECTIONS WILL BE ATTACHED TO THE PLANS. THE STATE IS TO PERMIT AND APPROVE THE ELECTRICAL WORK. RMITS 4) ELECTRICAL CODE COMPLIANCE WILL BE DETERMINED BASED ON FIELD INSPECTIONS PERFORMED BY THE STATE ELECTRICAL INSPECTOR, (303) 869-3458. PLEASE HAVE THE INSPECTOR SIGN THE BUILDING CARD OR PROVIDE WRITTEN DOCUMENTATION OF THE INSPECTIONS. 5) THE ELECTRICAL CODE REOUIRES A SEPARATE ELECTRICAL PERMIT FOR LOW VOLTAGE FIRE ALARMS THAT HAS AN ALARM PANEL AND SEND A NOTIFICATION TO THE FIRE DISTRICT WHEN UNDER ALARM. A ROUGH-IN INSPECTION WITH THE STATE ELECTRICAL INSPECTOR IS REOUIRED (303)869-3458. PLEASE HAVE THE INSPECTOR SIGN THE BUILDING CARD OR PROVIDE WRITTEN DOCUMENTATION OF THE INSPECTION. 6) THE FIRE SPRINKLER AND ALARM ARE REOUIRED TO BE INSPECTED AND APPROVED BY THE LOCAL FIRE PROTECTION DISTRICT. PLEASE PROVIDE SHOP DRAWINGS TO THE FIRE DISTRICT FOR REVIEW AND SCHEDULE THE INSPECTIONS ACCORDINGLY. PLEASE HAVE THE FIRE MARSHAL SIGN THE INSPECTION CARD WHEN THE ROUGH INSPECTION IS APPROVED AND WHEN THE FINAL INSPECTION IS APPROVED. 7) COMBUSTTBLE MATERTAL tS LTM|TED rN TYPE IAND ryPE ll CONSTRUCTION. SEE IBC 603 FOR ALLOWED COMBUSTIBLE MATERIALS. 8) ALL EXTERIOR LIGHTING lS TO BE DOWNCAST AND SHIELDED. 9) THE WALLS SURROUNDING THE TOILET ARE TO BE NON-ABSORBENT FOR A HEIGHT OF 48" AND 2' PAST ON EACH SIDE OF THE TOILET. 1O)ALL ACCESSIBLE DOOR HARDWARE SHALL HAVE A SHAPE THAT IS EASY TO GRIP, tNCLUDING POCKET AND SLIDING DOORS. (ANSI A117.1 - 404.2'6) 1 1 )GRAB BAR BACKING lS TO BE lN PLACE FOR ALL TOILETS AT FRAMING INSPECTION n)TNEWOOD CALLED OUT FOR THE CETLTNG lS REOUIRED TO BE FIRE-RESlSlTlVE.