HomeMy WebLinkAboutFire Sprinkler Final Inspection ReportGlenwood Springs Fire Department 806 Cooper Ave Glenwood Springs, CO 81601 Phone: (970) 384-6480 Construction - Commercial Fire Sprinkler Final Inspection Report Inspection Status Inspected by Completed at Completed Estevan Sandoval 01/02/2025 14:00:00 Business Name: --Date/Time of Inspection: 01/02/2025 14:00:00 Address: 603 DRY PARK RD, GLENWOOD SPRINGS, CO, 81601 Inspected by: Estevan Sandoval Suite/Unit: --Inspection Status: Completed Inspection Number: GSFD-2025-0000009 EXPLANATION OF PERIODIC FIRE INSPECTION REPORT AND YOUR RESPONSIBILITIES AS BUSINESS OWNER, MANAGER OR DESIGNATED REPRESENTATIVE ORDER TO COMPLY: City Ordinances and General Statutes charge the Fire Code Official with the responsibility of protecting the people and properties from the ravages of fire. This is accomplished by an organized program of inspections, and enforcement of Codes, Statutes, and Standards intended to minimize the community's fire loss. If there are any questions or needs for assistance with the correction of the violations, don't hesitate to contact The Glenwood Springs Fire Marshals Office at fire.prevention@cogs.us Inspection Condition: Pass ITEM: Is sprinkler system in a ready condition for the inspection? Pass ITEM: Is the occupancy in a ready condition for the inspection? Sprinkler Components: 1 / 3 Inspection #GSFD-2025-0000009 Pass ITEM: Static water pressure at the riser is sufficient for the system per plans Pass ITEM: A water-flow switch is installed on the riser above the check valve and main drain. Pass ITEM: A spare sprinkler head box with head and ITV wrench is installed near the riser. Pass ITEM: Sprinkler heads are installed per plans, per NFPA standards, and provide required protection per MFC and NFPA Pass ITEM: Are sprinkler heads clear of paint and debris? Pass ITEM: Are sprinkler head trim plates in place? Pass ITEM: Is the hydraulic plate installed with correct information? Functionality: Pass ITEM: Does the monitored water-flow pressure switch activate horn & strobe and/or FA system in a timely fashion? REMARK: 18 seconds 2 / 3 Inspection #GSFD-2025-0000009 Pass ITEM: Is the main control valve left in the open position? Pass ITEM: Are sprinkler system information/maintenance form provided? Additional Notes: Pass ITEM: Verify fire sprinkler fitter's license Inspection Signatures Inspector Signature __________________________ Estevan Sandoval -- -- 970-977-7040 steve.sandoval@cogs.us Powered by TCPDF (www.tcpdf.org) 3 / 3 Inspection #GSFD-2025-0000009