Blower Door Test
Testing Company: Name:C5 Energy Inspections Address:2215 Rosewood Ln Grand Junction, COLORADO 81505 Phone: 970-250-1352 C5EnergyInspections.com Technician: Name:Brian Chesney Credentials:BPI Certified ID #5068969 Email:c5energygj@gmail.com Building Information: Project ID:325 Eagle Ridge Dr. parachute Address:325 Eagle Ridge Drive Parachute, Colorado 81635 Geo-Tag Data:Latitude: 39.444266 Longitude: -108.032298 Timestamp: 2024-12-30 11:18:22 Customer Information: Name: Address: Measured Leakage:2.74 ACH50 Leakage Target:3.00 ACH50 Compliance with Leakage Target:Pass Test ID:Blower door Purpose of Test:IECC 12/15 Env. Leakage Measured CFM50:806.5 Effective Leakage Area: 44.4 in² Building Volume:17,676.0 ft³Enclosure Surface Area: 0.0 ft² Coefficient (C):63.4 Exponent (n): 0.650 (assumed) Test Standard:RESNET 380 One-Point Test Mode: Depressurize Test Characteristics:Indoor Temp: 42 °F Altitude: 5,354.0 ft Outdoor Temp: 42 °F Time Average Period: 10 seconds Test Date and Time:2024-12-30 11:48:23 10% Adjustment Applied: No Envelope Leakage Test Test Readings: Target (Pa)Bldg (Pa)Adj Bldg (Pa)Fan (Pa)Flow (cfm)Config Baseline 0.4 -50.0 -52.0 -52.4 -193.4 823.9 Ring B Test Equipment: Flow Device:Model 3 110V Fan Pressure Gauge:DG1000 Serial #: 13229 Calibration Date: 2024-08-27 Deviations from Standard: None Comments: None Envelope Leakage Test Page 2 of 2Report by TEC Auto Test 1.10.0 (145), © 2024 The Energy Conservatory, Inc.