HomeMy WebLinkAboutSpec SheetlUIETLSPAN"
c l{LJEElffco.patty
CF 7,2 INSUL
I N S U LATE D M ETAL. IJIIALL
WITH PUR FOAM CORE
The eF V.2 fnsu{-Rifu insulated mefs/ p$nel cornbir?es
s frsrlifrc${}! V"2 rfb panei with sn insalatetl e#re' Witt;
s Ssfd, ruf:Sed p&ffern, ffiis pome/ cf,€#f€s {T ffnrqffe
buildittg pra{i!e fi'iaf sfs;'lds *uf, ldssJ for trfi3t €offilTtercisl
*r industrfsl appf ieutian" The 7.2 lnsu!-Rih pune! rcn
Se rnsf*/ied ba{h vertieally and horiz*ntu{ly, ollowing
$,'chifecfs fl ex t tti I i{y with rle s i g n.
PRO DUCT SPECIFICATIONS
L0cr( & GR00vE
SYSTEI'
PAITIEL PROF!I-E
PANTT
I
I
$ll DT l{ . Nominal 36"
T H I C K ll ES S " 3", 4n Rib helght included in thlckness
LEIIGTH NON-DIRECTIONALEMBOSSED
8'-On to 32'-On Horizontal
8'-Oo to 4O''On Vertical
UNEMBOSSED
8'-On to 32'-Ou Hodzontal
8'-O" to rKl''O" Veftical
E X T E R I 0 R P B 0 F I L E' 7.2" on center rlb pattern, I t/z' tall, embossed
or unembossed
E XT E R I 0 R FA C E . G-90 galvanlzed or AZ-5O alumlnum-zlnc coated
steel in 26,24 and o22 Ga.
M TE R I 0 R P R0 FI L E' Mesa, nominal !6" deep, embossed or
unembossed
DESIGH FEATURES & BEf{EFITS
I N T E R I 0 R FA C E' G-90 galvanized or AZ-5o alumlnum-zlnc coated
steel ln 26,24 and 22 Ga,
C 0 R E ' Foamed-in-place, PUR Foam Core, zero ozone depleting
{zero ODP) Class l foam
J 0l ll T . Ofiset double tongue-and-groove wlth extended metal shelf
for positive face fasteninga
U.FACTORS At{D R-VAI.U ES*
u-FAeroR tET{,Jft'ft''"F} R-VALUE {h'ft2."F/B'rLt)
PTNELII'II'TFt 36"PANELWDIH:36"-----l-.;;--
lvr.Wre
4" | 0.04ir
350
15.2
23.3
'Bssed on Asfir't Cl36it and lhemol modeltng,
*not arallaHe ln unembossed
A Through fastenlng requfred 8t ponels ends
" Sweeplng pro{lle with unique shadow effects
. Utillzes concealed clips and elimlnates thermal short circults
" Easy dnd fast installatlon, wlth reduced constructlon labor costs
' lnterior dnd elderior applicatlons
. Can be used in conjuncllon wth other Metl-Span CFJolnt proflles of
the same thlckness
.Metl-Span: All-ln;One Fedorrnance
172O Lakepointe Drive, Sutle 1O1,'Lewisville, Texas 75057 tp) 87'585'9969 metlspan'conr
@ Metl-Span, e Nucor Company. Al rightb tesewed' Pilntsd in thi U.s'A
st<u# 307209991173
ASTM E84 Sutface Burning Characlerlstlcs of Euildlng
Materials
ASTM EI19 Flre Tests of Bulldlng Constructlon Matertals
FM 4880 Class 1 Flre Rating of lnsulated lfdall, Celllng
and RoofPanels
NFPA 259 Test Method for Potential Heat of Building
Materl6ls
NFPA 285.19 Evaluation of Fire Propagation
Chorocterlstlcc of Exterlor Non-Lood Beorlng
Wall Adsemblles
NFPA 286 Fire Tes'ts for Evaluating Contribution of Wall
and Celllng Finlsh to Roof Fire Growth
CANruLCSlOl Fire Endurance Tests of Building
Construclion and Materials
CANruLCSlOl Flre Endurance Tests of Bulldlng
Conslruction and Materlals
CANnJLC 5102 Surface Burning Characteristlcs of Building
Moterlals and Assembltes
CAN/ULC St34 Fire Test of Exterior Wall Assemblies
CANruLC SI38 Flre Gro,rrth of lnsulated Bulldlng Panels ln a
Fuil.Scale Room Conflguration
ASTM E72 Strength Tests of Panels for Bullding
Construcllon
ASTM E15S2 Structurdl Performance of Metal Roof
and Sldlng Systems by Unlform Statlc Alr
Pressure Dlferences
FM 488t Class I Exteriorwall Structural Perfonnance
ASTM C518 Steady-State Thermal Transmission
Propertles by Me6ns of the Heat-Flor Meter
Apparstus
ASrM C1363 Thermal Performance of Bulldlng Materials
and Envelope Assemblies
ac?lt Etodru I tvt LaoJ Rate of Alr Leakage Through Curtaln Wails
Under Specified Pressure Dtfrerences
/tcTM Ell2t Water Penetratlon cf Erterior Walls by
Uniform Static Air Pres€ure Differences
TESTING: CF 7 .2 INSUL-RIB INSULATED METAL WALL PANEI-
TESTi
A PPROYAL
TEST TIETI{OD TEST TITLE fTESU LT$
Flro lJc Flarne spread <25, smoke developed <45O
One hour non-load besrhg ratlng wth two layers of
TypeXGypsum
Veflcal or horlzontal installatlon
Product approved
E<teriorwall requires FM 4881 approval
Fotential heat sf foam plastic insulation contained in
the assembly tesled in accordance with NFPA 285
Panel assembly met the !'equlrements of the
stondod
Test speclmen met the crlteria of the IBC Section
803.1.2.1
Flre Canada One hour nonJoad bearlng flre rating wlth two
layers of Type X Gypsum
Meets 15 minute siayJn-place requirements
Meets the Natlonal Building Code of Canada
requlremenb
Complles wlh the flre-spread and heat-flux
limitations required bythe National Buildlng Code
cfCanada
Metthe crlteda ofthe standard
Struc{ural See Load Chart
See Load chart
See FM Wall Load Chart
Thermal
Ferlormance
K-Factor of OJ14 BTU.in/hr.ft2.'F at 35" F mean core
See Thermal Performance Guide
^tr
tJL-{--xla ttttttllottgta 'hht etd2 -.aA6J\vtvt lrilgtr, 9tzw l/it
Vertical or horizontal installaton
lfator lnflltratlon No uncontrolled leakege when tested to a slatic
pressure of20 p$
Vertical or horlzohtal tn$allauon
Speclal Approvat State oiFlorlda Product Approval for the State of Florida Product has State ofFlorida approval
Descrlpflons and specl{lcatlons contalned hereln were in effect at the time this publication was approved for printlng, ln a contlnulng efoft to
reflne and lmprove products, Metl-Span reserves the rlght to discontlnue producls at any tlme or change speclflcatlons andlor designs wlthout
incurrlng ohltgatlon, Ta ensure you harrc the latest infgrmatian avallable, please lnquire or vlslt orrr webslte at metlspan.com,