HomeMy WebLinkAboutConditions of PermitCONDITIONS OF PERMIT B LR E- 12-24-9028 EDGAR ROJO New 2,040 sq ft stick-built single-family dwelling residence on crawl space (floor plan includes 1,680 sq ft 2-bedroom primary residence with an attached 360 sq ft 1-bedroom ADU on lower level) 1 ) ALL WORK SHALL COMply W|TH THE 201s INTERNATTONAL RESIDENTIAL CODE (l.R.C.)AND 2018 I NTERNATIONAL ENERGY CONSERVATION CODE (I.E.C.C.) 2) PROPOSED IMPROVEMENTS ARE SUBJECT TO ALL APPLICABLE ITEMS CONTAINED IN THE ATTACHED "GARFIELD COUNry BUILDING REOUIREMENTS". NUMBER REFERENCES NOTED ON PLANS REFER TO SPECIFIC ITEMS ON THIS LIST. 3) ELECTRICAL PERMITTING AND INSPECTIONS BY COLORADO STATE ELECTRIC BOARD. ELECTRICAL ROUGH-IN APPROVAL IS REQUIRED AT FRAME INSPECTION. ELECTRICAL FINALAPPROVAL IS REQUIRED FOR FINAL INSPECTION & CERTIFICATE OF OCCUPANCY. 4) ALL EXTERIOR LIGHTINC TO BE DOWNCAST AND SHIELDED. 5) WILDFIRE MITIGATION RECOMMENDATIONS: SHOULD COMPLY WITH WILDFIRE MITIGATION AND DEFENSIBLE SPACE RECOMMENDATIONS PER COLORADO STATE FOREST SERVICE AND LOCAL FIRE DISTRICT. PLEASE REFER TO THE GARFIELD COUNTY COMMUNIry DEVELOPMENT WEBSITE FOR ADDITIONAL I NFORMATION, 6) OPEN HOLE SOTLS REPORT rS REOUTRED AT FOOTTNG INSPECTTON AND PR|OR TO ANY CONCRETE POUR. PROVIDE COPY OF GEOTECHNICAL ENGINEERS REPORT TO THE BUILDING INSPECTOR. 2,000 PSF soil bearing. 7) BLOWER DOOR TEST tS REQU|RED. MUST SUBMIT BLOWER DOOR TEST REPORT TO GARFIELD COUNTY COMMUNITY DEVELOPMENT DEPT. OFFICE PRIOR TO SCHEDULING FINAL BUILDING INSPECTION / C.O. FINAL. S) SEPTIC SYSTEM REVIEWAPPROVALS: PRIOR TO BUILDING INSPECTION & CERTIFICATE OF OCCUPANCY PROVIDE FINAL APPROVAL/SIGN-OFF BY GARFIELD COUNTY'S PUBLIC HEALTH DEPT. 9) PRESCR|pTtVE PATH USTNG 2018 rECC TABLE R402.1.2 CHOSEN FOR ENERGY COMPLIANCE OF THIS HOME. MANUAL J REPORT ATTACHED FOR REFERENCE. ALL NEW HOMES TO HAVE WHOLE-HOUSE MECHANICAL VENTILATION SYSTEM INSTALLED (201s IRC TABLE m1507.3.3(1 )AND (2) SHOWN ON COVER SHEET. 10) 01/22/2025 MEETING BETWEEN OWNER AND GARFIELD COUNry PLANS EXAMINER: BEDROOM 3 / ADU _ SHOWN ON A.2.01 TO HAVE ONE-HOUR FIRE SEPARATION AND 20-MINUTE SELF-CLOSING DOOR AND INCLUDE FIRE-RESISTIVE FLOOR ASSEMBLIES IN FLOOR WALL AND ROOF ASSEMBLIES SHOWN BYARCHITECT OF RECORD ON A.5.01. LOWER LEVEL ADU OF 360 SO FT, INCLUDES SEPARATE CLOSET, BATHROOM, 1 BEDROOM / KITCHEN LIVING EFFICIENCY AND INDEPENDENT DOOR EXIT TO YARD. NO GAS-FIRED APPLIANCES CAN BE INSTALLED IN THE ADU BEDROOM LIVING SPACE. PROPOSED COOKTOP WILL BE ELECTRIC APPLIANCE AND INSTALLED PER MANUFACTURER'S INSTALLATION INSTRUCTIONS. ADU KITCHEN RANGEHOOD MUST BE SIDE. VENTED; VENT MUST NOT PENETRATE THE FIRE-RESISTIVE RATED ROOF ASSEMBLY. 1 1) TNASMUCH AS THE PROPOSED 360 SO FT LOWER LEVEL ADU lS WELL UNDER 1,200 SO FT MAXIMUM FOR ADU'S ALLOWED AS A USE BY RIGHT UNDER GARFIELD COUNTY LAND USE AND DEVELOPMENT CODE, AND INASMUCH AS PERMIT HOLDER REPRESENTS THE STRUCTURE SHALL REMAIN UNDER SINGLE- OWNERSHIP WITH NO FUTURE SUBDIVISION OR SPLIT OF THE LOT, NO FURTHER LAND USE CHANGE PERMIT WAS REOUESTED DURING THIS PERMIT REVIEW. IF AT SOME FUTURE POINT, CURRENT OR FUTURE OWNER SHOULD WISH TO CONSTRUCT AN ADU OR SECONDARY DWELLING ELSEWHERE ON THE PROPERTY, THEN OWNER MAY NEED TO DECOMMISSION / DELETE KITCHEN COOKING APPLIANCE FROM THE 360 SO FT ADU ANDi OR OBTAIN SEPARATE LAND USE CHANGE PERMITS FOR FUTURE BUILDING PLANS. 0 -r-- tl. hsto -.-f