Loading...
HomeMy WebLinkAboutBlower Door TestFrom: Chris Taylor chris@confluencearchitecture.cam Subject: 567 Saddle Back Rd. Final blower door Bate: Jan 21, 2025 at 3:38:16PM To: Rafael Medina rafael@peak3aspen.com Rafael, Attached is the blower door report and invoice from today's test. Let me know if you have any questions. Cheers, Chris Taylor architecture â– sustoina architecture â– sustainabiIity IIRIVillegu Rnad g410 Carbondale. En 61623 971IH63.9720 wwvenon0uencearchilecWre cmn 1101 Village Road 9L-I1) Earhondale. Co 8I623 979.963.9720 www.tanflumtoorchitecture.cem Residential Air Infiltration Test Report Test date: 1/21/2025 Project name: Gammlll Address: 567 Saddleback Road Garfield Code: 20181ECC Conditioned volume: 53,237 Attic: Vaulted/ non -vented Crawlspace: conditioned/ non -vented Garage: excluded Measured airflow: 1,516 Temperature; Inside: 60 Temperature; Outside: 7 Elevation: 6,054 Corrected airflow: 1,416 20151ECC maximum allowed leakage rate: 3.0 Tested air leakage rate: 1.6 Test code compliance: PASS Cubic Feet CFM50 Cubic Feet per Minute at 50 Pascal CFMW Cubic Feet per Minute at 50 Pascal ACH50 Air Changes Per Hour at 50 Pascal ACH50 Air Changes Per Hour at 50 Pascal