HomeMy WebLinkAboutUpdated Floor plan for new garagePROPOSED ENTRY LEVEL PLAN A2.2 23'-9" 22'-10" +/-26'-11" 14'-0" CLR. 23'-9" 4'-10 1/2"4'-10 1/2" NEW GARAGE CONC. SLAB 2'-0" 2'-0" POLARIS RANGER 58 W x 110 L x 73 H, VERIFY 4'-0" 27'-9" 2'-8" EARTHROAMER 119 W x 360 L x 156 H 47'-9" 16'-4" 30 DEGREES, TYP. 5'-0" 31'-11" EARTHROAMER HD 119 W x 420 L x 158 H 46'-5" 8" 4 3/4" 3 1/4" 5 1/2" 2 1/2" 2 1/2" HSS5x COL. SEE STRUCT. HSS5x COL. SEE STRUCT. 2 1/2" 15'-4" CLR. FOC FOC 8"3'-6 1/2"8"3'-6 1/2" FOC FOC 5 1/2" +/-8'-1" BETWEEN STRUCT COLS. +/-41'-0" VERIFY EXISTING DRIVEWAY - EXISTING ENTRY - EXISTING GARAGE CONC. SLAB EXISTING ASPHALT PAVING EXISTING LANDSCAPE RETAINING WALL EXISTING PORTE-COCHERE - UP 2R EXISTING ENTRY PORCH - NEW 1:12 SLOPE RAMP, VERIFY EXACT LENGTH IN THE FIELD EXISTING CONCRETE WALK +/-4'-5 1/4" +/-12'-0" EXISTING +36" GUARDRAIL @ PORCH TYP. OPEN TO LIGHTWELL BELOW R=7 1/2" T=11" LEVEL LANDING3'-0"CLEAR +/-15'-0" VIF +/-4'-0" T. SLAB 100'-0 EXISTING MUDROOM - NEW GRASP RAIL @ EA. COLUMN EXISTING ELEC MAIN DISCONNECT PANEL EXISTING ELEC CONDUIT TO EXISTING DISCONNECT PANEL FIN. FLR. +/-105'-8 3/4 +/-4'-0" +/-9'-2" LANDINGRAMP FIN. FLR. +/-105'-8 3/4 EXIST DOOR EXIST OVERHEAD GARAGE DOOR EXIST OVERHEAD GARAGE DOOR NOTE: RELOCATE EXISTING WINDOW TO WEST FACADE OF NEW GARAGE ADDITION, SEE NEW FACADE ELEVATIONS - OWNER'S OPTION TO RETAIN EXISITNG WINDOW TO PROVIDE LINE OF SITE CONNECTION TO NEW GARAGE FROM EXISTING GARAGE, VERIFY IN THE FIELD SLOPE DOWN SLOPE DOWN SLOPE DOWN SLOPE SLAB DOWN TO DRAIN 1/8"MIN./FT., TYP., U.N.O. HOSE BIBB NOTE: PROVIDE FROST-FREE HOT/COLD HOSE BIBB, VERIFY EXACT LOCATION IN THE FIELD NOTE: PROVIDE 4" DIAMETER MIN. FLOOR DRAIN, IN NEW GARAGE SLAB, ROUTE UNDERGROUND IN RIGID PVC PIPE AND TERMINATE TO DAYLIGHT OR TO DRYWELL AS REQUIRED BY THE OWNER AND AS REQUIRED BY THE BUILDING INSPECTION REQUIREMENTS NOTE: ALIGN CENTER OF NEW EXTERIOR DOOR TO EXISTING DOOR DASHED LINE INDICATES LINE OF NEW/EXISTING OVERHANG ABOVE, TYP. RAKE AND EAVE OVERHANG DIMENSION, TYP., U.N.O. STEP DN. T. EXIST. SLAB +/-105'-6 1/2 VERIFY T. EXIST. SLAB +/-104'-3 1/2 VERIFY T. EXIST. SLAB +/-104'-3 1/2 VERIFY APPROXIMATE LOCATION OF EXISTING ATTIC ACCESS ABOVE APPROXIMATE LOCATION OF NEW 22"x30" ATTIC ACCESS ABOVE UP 10R T. EXIST. LANDING +/-105'-8 3/4 EXIST. 4" DIA. RADON RISER EXIST DOOR EXIST 1/2 STOP PASS-THRU ELEVATOR EXIST WINDOW ABOVE 45 DEGREE WINDER TREAD NEW PAIR 42"x96" DOORS T. DRAIN +/-99'-9 VERIFY NEW WINDOW ABV. NEW WINDOW ABV. NEW WINDOW ABV. NEW WINDOW ABOVE NEW WINDOW ABOVE NEW WINDOW ABOVE 24" DIA.CMPRSR.VIF NOTE: NEW RAMP IS OPTIONAL, VERIFY CONSTRUCTION IN THE FIELD WITH THE OWNER 8" TILE CONC SLAB T. NEW SLAB PERIMETER +/-100'-0 MATCH EXIST. SLAB, TYP. EXISTWINDOWABOVE E/V OUTLET APPROXIMATE LOCATION OF FUTURE E/V CHARGING OUTLET +/-28'-6" EXISTING BUILDING FLOOR ELEVATION BUILDING ELEVATION 100'-0" = SITE ELEVATION 6086.58' VIF 36"x60" DBL HUNGN1C FACADE ORIENTATION'N' - NORTH'E' - EAST'S' - SOUTH'W' - WEST FLOOR LEVEL'1' - BASEMENT'2' - ENTRY LEVEL'3' - UPPER LEVEL WINDOW DESCRIPTIONSEE FACADE ELEVATIONFOR HANDING WINDOW SYMBOL 72"x96" SL GL DR TEMP GL 10N FACADE ORIENTATION'N' - NORTH'E' - EAST'S' - SOUTH'W' - WEST DOOR NUMBER'10-19' - BASEMENT'20-29' - ENTRY LEVEL'30-39' - UPPER LEVEL DOOR DESCRIPTIONSEE FACADE ELEVATIONFOR HANDING EXTERIORDOOR SYMBOL WINDOW IDENTITY TAGA,B,C, ETC. DOOR/WINDOW SYMBOL LEGEND 1 NOTE:FENESTRATION U-FACTOR,SEE BUILDING SECTIONS FOR MINIMUM U-FACTOR,TYP. SMOKE ALARM NOTES SMOKE ALARMS ARE REQUIRED TO BE LOCATED AT EACH STORY INCLUDING THE BASEMENT LEVEL (R314.3). 5. SMOKE ALARMS ARE REQUIRED TO BE LOCATED IN EACH SLEEPING ROOM (R314.3). 4. SMOKE ALARMS ARE REQUIRED TO BE WIRED TO THE PRIMARY POWER SOURCE AND HAVE BATTERY BACKUP. (R314.6) 3. SMOKE ALARMS ARE REQUIRED TO BE INTERCONNECTED SUCH THAT ACTUATION OF ONE WILL ACTUATE ALL SMOKE ALARMS. (R314.4) 2. SMOKE ALARM LOCATIONS - A SMOKE ALARM IS REQUIRED OUTSIDE OF EACH SEPARATE SLEEPING AREA. (R314.3) AN APPROVED CARBON MONOXIDE ALARM SHALL BE INSTALLED OUTSIDE OF EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS WHEN FUEL-FIRED APPLIANCES ARE INSTALLED AND WHEN THE DWELLING HAS AN ATTACHED GARAGE. (R315.3) 1. 4 OR MORE RISERS - STAIRS WITH 4 OR MORE RISERS ARE REQUIRED TO HAVE CONTINUOUS HANDRAILS (R311.7.8). 4. SPACE UNDER STAIRS - ENCLOSED USEABLE SPACE UNDER STAIRS SHALL BE PROVIDED WITH 1/2" GYP. BD. ON UNDERNEATH SIDE OF WALL AND SOFFITS (R302.7). FIRE STOP STAIRS AT STRINGERS (R302.11) 5. STAIRWAY MINIMUM HEADROOM REQUIREMENT IS 6'-8" CLEAR (R311.7.2).6. GUARDRAILS FOR BALCONIES, ELEVATED DECKS AND STAIR LANDINGS THAT ARE MORE THAN 30" ABOVE GRADE OR FLOOR BELOW SHALL BE A MINIMUM OF 36" HEIGHT. CLEARANCE BETWEEN INTERMEDIATE PICKETS MUST BE SUCH THAT A 4" DIAMETER SPHERE CANNOT PASS THROUGH (R312). 7. 1.) PROVIDE "JELD-WEN", OR APPROVED EQUAL ALUMINUM-CLAD WOOD WINDOWS WITH U=0.30 OR LESS. 2.) CONFIRM ALL WINDOW SIZES PER OWNERSHIP SELECTIONS UNLESS NOTED OTHERWISE. 3.) THE WINDOW IMAGERY REPRESENTS SIZE AND TYPE ONLY. THE DIVIDED LITE(S) ARE TBD BY OWNER. 4.) SEE THE ELEVATIONS FOR OPERATION. 5.) FIELD VERIFY ALL ROUGH OPENINGS. 6.) SLIDER DOORS SPECIFIC PER CLIENT SELECTION. 7.) CONCUR PER MANUFACTURER INSTALLATIONS AND SPECIFICATIONS FOR DOOR AND WINDOW PLACEMENTS. 8.) GLAZING IN HAZARDOUS LOCATIONS IS REQUIRED TO BE GLAZED WITH SAFETY MATERIAL. (R308.3 AND R308.4). 9.) WINDOWS LOCATED MORE THAN 72" ABOVE THE GRADE BELOW AND LESS THAN 24" ABOVE THE FLOOR MUST BE PROVIDED WITH FALL PREVENTION DEVICES THAT COMPLY WITH ASTM F 2090 OR HAVE A MAXIMUM OPNEING OF 4 INCHES. (R312.2.1) WHERE WINDOW OPERATING CONTROL DEVCIES (WOCD'S) ARE UTILIZED, SUCH DEVICES SHALL MEET ASTM F2090-10 STANDARD SPECIFICATION FOR WINDOW FALL PREVENTION DEVICES WITH EMERGENCY ESCAPE (EGRESS) RELEASE MECHANISMS. 10.) EGRESS DOORS - ALL EGRESS DOORS SHALL BE READILY OPENABLE FROM THE SIDE FROM WHICH EGRESS IS TO BE MADE WITHOUT THE USE OF A KEY OR SPECIAL KNOWLEDGE OR EFFORT (R311.1). DOOR AND WINDOW GENERAL NOTES FURNITURE SHOWN ARE NOT INCLUDED IN THE CONTRACT (NIC) AND WHERE INDICATED ARE FOR COORDINATION OF ELECTRICAL REQUIREMENTS ONLY. FURNITURE, INTERIOR ACCESSORIES & BUILT-INS 1. AT CLOSETS WHERE A SHELF AND POLE (SH & P) ARE INDICATED, THE INSTALLATION SHALL BE LIMITED TO ONE (1) SHELF AND ONE (1) POLE MOUNTED AT +66" ABOVE THE FINISHED FLOOR, TYP., U.N.O. 2. BUILT-INS WHERE SHOWN ARE NOT INCLUDED IN THE CONTRACT (NIC) AND WHERE INDICATED ARE FOR COORDINATION OF ELECTRICAL REQUIREMENTS ONLY. 3. CONTINUOUS HANDRAIL - A CONTINUOUS HANDRAIL WITH RETURNS @ +34" TO 38" ABOVE THE FINISHED STAIR NOSINGS IS REQUIRED ALONG THE STAIRWAY PER 311.7.8 HANDRAIL GRIP CROSS-SECTIONAL DMENSIONS TO BE 1 1/4" TO 2". OPENINGS IN STAIRWAY HANDRAIL & GUARDRAIL - THE MAXIMUM SIZE OF OPENING IN THE HANDRAIL/GUARDRAIL ON THE OPEN SIDE OF A STAIRWAY IS 4 3/8 INCHES, 4" ELSEWHERE PER 312.1.3 MINIMUM STAIR DIMENSIONS - MAXIMUM RISER 7 3/4"; MINIMUM TREAD 10"; MINIMUM STAIR WIDTH 36" (R311.7.5.1 & R311.7.5.2). SEE PLAN FOR SPECIFIC DIMENSIONS. STAIRWAY NOTES 1. 2. 3. 1 . BUILDING THERMAL ENVELOPE THE PERIMETER OF THE BUILDING THERMAL ENVELOPE IS DEFINED BY THE PERIMETER EXTERIOR WALL TYP., U.N.O. 2 . THE BUILDING PERIMETER WALLS, INCLUDING PERIMETER CRAWLSPACE WALLS; PERIMETER WALLS AGINST UNEXCAVATED AREAS (RETAINING WALLS); CATHEDRAL CEILINGS; ATTIC CEILINGS; AND CONDITIONED FLOORS OVER NON-CONDITIONED SPACE WILL BE INSULATED TO THE INSULATION STANDARDS IDENTIFIED ON THE BUILDING SECTIONS, TYP., U.N.O. 3.THE BUILDING PERIMETER WALLS, ARE FRAMED OF 2x6 STUDS @ 16" O.C., TYP., U.N.O. 10S 10W 10N 10E N1B N1C N1A E1A NOTE: RELOCATED EXISTING WINDOW, VERIFY EXACT ROUGH OPENING DIMENSIONS IN THE FIELD PRIOR TO FRAMING THE OPENING, SEE NEW FACADE ELEVATIONS. EXIST. 2-30"x30" VERIFY 24"x36" FX 24"x36" FX 24"x36" FX NEW 36"x80"SOLID COREEXTERIOR DOOR NEW 36"x80" DOOR 6'-8" 3 1/2" NEW TLT. RM. TILE 12" NOTE: PROVIDE WALL-HUNG, GAS FIRED ON DEMAND HOT WATER HEATER WTR HTR FAU GAS-FIREDBOILER24"x24"VIF 8'-5 1/2" NEW ENCLOSED STORAGE ROOM TILE NEW MECH ROOM VINYL NOTE: NEW MECH. ROOM, TOILET ROOM AND STORAGE ROOM FLOORS ARE CONSTRUCTED OVER A NEW CRAWLSPACE FOR EASE OF PLUMBNG INSTALLATION 15'-10 1/2" 7'-9" NEW 36"x80" SALOON DOOR NEW ELEC SUB-PANEL EXIST. POST REMOVED +/-12'-8" VERIFY FG FG TILECONC SLAB T. PLY. 99-10 7/8 T. CONC. 99'-9 3/4 15'-10 1/2" E2AE2BE2C 24"x36" FX 24"x36" FX 24"x36" FX 4 1/2" +/-10'-9 3/4" VIF 23'-9" +/-2'-2" WINDOW R.O. VIF +/-10'-9 3/4" VIF 4 1/2" FAU BELOW +/-9'-10 1/2"GRID LINE GRID LINE OPEN TO NEW GARAGE BELOW NEW STORAGE LOFT - LINE OF +/- 3'-9" HEAD CLEARANCE T. PLY. 109'-1 3/4 NOTE: BALOON FRAME SOUTH WALL OF NEW STORAGE LOFT, DO NOT BEAR WEST END OF THE WALL ON THE EXISTING GARAGE WALL BELOW, SEE STRUCT. DWGS 12'-8 1/2" DUCT SOFFIT - REMOVABLE INSULATED ATTIC ACCESS HATCH, 22"x30" MIN., ACCESS TO NEW OVERFRAMED ATTIC NEW OVERFRAMED ATTIC AT EXISTING GARAGE ROOF, SEE ROOF PLAN LINE OF EXISTING GARAGE WALL BELOW, TYP. 1/2" CLR. 39'-7 1/2" EQ. EQ. VENTED ATTIC - EQ. EQ.EQ. +/-6'-7" VIF +/-3'-7" VIF +/-4'-2" VIF PROPOSED STORAGE LOFT PLAN @ 1/4"= 1'-0"NORTH PROPOSED ENTRY LEVEL PLAN @ 1/4"= 1'-0"NORTH EXIST. POST REMOVED EXIST. POST REMOVED EXIST. POST REMOVED 4'-0" CONC. LANDING STEP DN. +/-2 1/4" +/-12'-5 1/2" +/-12'-0"5 1/2" 22x30 crawlspace access MECH. ROOM DUCTS ARE ROUTED UP THROUGH THE FLOOR OF THE STORAGE ROOM ABOVE AND THEN ARE ROUTED HORIZONTALLY THROUGH THE EAST/WEST SOFFIT AT THE CEILING OF THE NEW GARAGE, VERIFY EXACT DUCT ROUTING IN THE FIELD NEW 36"x80" SOLID CORE DOOR, 45 MINUTE LABEL, SELF CLOSER 8 1/2" 1'-3"+/-2'-1 1/2"6'-1" 45 DEGREES 1 1/2" 3 1/2"3" 5 1/2" 3'-8 1/2" +/-4 1/2" NEW 36"x80" SOLID CORE DOOR EQ. EQ. 3 1/2" 3 1/2" 1" CLR. BETWEEN WALLS NOTE: NEW WALLS ARE INSULATED TO REDUCE SOUND TRANSFERENCE TO EXISTING WALLS 11 1/2" 3 1/2" 5 1/2" TILE VINYL NOTE: T. PLY. FLOOR ELEV TO ACCOMODATE THINSET CERAMIC TILE (+/- 1/2" THK.) OVER, 1/8" THK. ANTI-FRACTURE MEMBRANE OVER 1/2" THK. HARDI BACKER BOARD OVER STRUCT PLY. FLOOR SHTG., TYP. 5'-10 1/2" 6'-0" N2G 24"x36" FX ABOVE 6'-0" 6'-0" 6'-0" 6'-0" 6'-0" N2F 24"x36" FX ABOVE N2E 24"x36" FX ABOVE N2D 24"x36" FX ABOVE N2C 24"x36" FX ABOVE 24"x36" FX ABOVE N2B N2A 24"x36" FX ABOVE NOTE: EXIST. +/- 1/2" EXTERIOR STRUCT. SHEATHING TO REMAIN, SEE C/A4.2 NEWBI-FOLDGARAGE DOOR172"x 192 1/4"(14'-4"x16'-2 1/4") 2 A3.1 STL COL/ WALL CONN.4 4 PWRWALL 3 CAB. PWRWALL 3 CAB. PWRWALL 3 CAB. NOTE:POWERWALL CABINETS - VERIFY EXACT LOCATION AND QUANTITY OF CABINETS w/ THE SOLAR SUBCONTRACTOR 5 24-0424 A2.2 date: remarks: job no: 24-0424 drawn by: xx checked by: xx date printed:xx 2 4 80 GLENW OOD SPRINGS 815 Blake Avenue Glenwood Springs, CO 81601 Phone (970) 947-9014 Fax (970) 947-9137 Palomino Design-Build PC www.palominodesignbuild.com Copyright Palomino Design-Build PC Architecture Development Construction Kennedy Residence Addition and Alterations 2074 CR 109 Glenwood Springs, Colorado 81601 03-01-24 Permit Submit Delta 1 Window ID 03-14-24 Delta 2 Env. Health Corr. 04-03-24 Delta 3 Env. Health Corr. 04-04-24 Delta 4 Toilet Rm 05-29-24 Delta 5 Powerwall Cabs 09-05-24 B D A A4.1 D C A4.2 A A4.1 B A4.1 B A4.1 C A4.2 A 2 7 3 5 1 C 4 6 BA C D A4.2 D A4.2