HomeMy WebLinkAboutLab Analysis-Well WaterClient:Over-the-Counter Customers Profile:Chemistry Testing Packages Sampled By:DAVID MULLENNEX Report To:DAVID MULLENNEX 132 RUSTY SPUR TR Rifle, CO 81650 Sample Summary Lab ID Sample ID Sample Type Method Date Collected Date Received Analyes Reported 2409190075 263-38 Water Anions, IC (EPA)09/18/2024 12:45 09/19/2024 12:37 3 2409190075 263-38 Water D 3739-83 09/18/2024 12:45 09/19/2024 12:37 1 2409190075 263-38 Water Dissolved solids, Gravimetric 09/18/2024 12:45 09/19/2024 12:37 1 2409190075 263-38 Water Metals, ICP-OES 09/18/2024 12:45 09/19/2024 12:37 5 2409190075 263-38 Water Metals, ICPMS (EPA)09/18/2024 12:45 09/19/2024 12:37 7 2409190075 263-38 Water NA 09/18/2024 12:45 09/19/2024 12:37 1 2409190075 263-38 Water Nitrate-Nitrite, FIA 09/18/2024 12:45 09/19/2024 12:37 1 2409190075 263-38 Water SM 2320 B 09/18/2024 12:45 09/19/2024 12:37 1 2409190075 263-38 Water SM 2510B 09/18/2024 12:45 09/19/2024 12:37 1 2409190075 263-38 Water SM 4500-H+B 09/18/2024 12:45 09/19/2024 12:37 1 2409190075 263-38 Water Total Coliform and E. coli P/A 09/18/2024 12:45 09/19/2024 12:37 2 Scientific Director Note: The samples were tested as received from the customer and the results in this report relate only to the samples tested. Unless otherwise indicated in this report, all test have been performed on site at the CDPHE laboratory. Analysis Report Colorado Department of Public Health and Environment 8100 Lowry Blvd. Denver, CO 80230 Tel: 303-692-3090 Fax: 303-344-9989 Workorder:4606106 Chemistry Testing Packages POWERED BY v.13.1.0 Report ID: Friday, November 1, 2024 12:44:21 PM 4606106-42232859 mg/L - milligrams per liter (ppm); ug/L micrograms per liter (ppb) MRL = Minimum Reporting Limit; BDL = Below Detection Limit; * = Comment applied "GL = Guideline Value; " "If you have any questions about how your results may impact your health, please contact Toxcall at 303-692-2606 or cdphe_toxcall@state.co.us" EPA provisional certification for methods 200.8,300.1, 504.1, 505, 524.2, 525.2, 531.2, 547, 548.1, 549.2, and 555. (EPA) - Method listed on EPA Safe Drinking Water Act (SDWA) accreditation. Visit https://cdphe.colorado.gov/laboratory-services/lab-accreditations to view certification status. Summary Workorder Comments HUMAN HEALTH Arsenic, Cadmium, Copper, Lead, Uranium, Fluoride concentrations are below EPA health-based standards. Iron, Manganese, Zinc, pH levels meet EPA aesthetic-based standards. Based on these results, it is strongly recommended that you use another source of water for drinking and cooking or treat this water to reduce the level of Coliform and Nitrate/Nitrite. The quality of the water would be improved if it was treated for Solids-Dissolved, Sulfate, and Chloride . Task Comments 2409190075 - 42224450 - INOC/17803 Analysis of EPA 300.0 was subcontracted to a local state certified drinking water laboratory (cert. ID CO00063) Analysis Report Colorado Department of Public Health and Environment 8100 Lowry Blvd. Denver, CO 80230 Tel: 303-692-3090 Fax: 303-344-9989 Workorder:4606106 Chemistry Testing Packages POWERED BY v.13.1.0 Report ID: Friday, November 1, 2024 12:44:21 PM 4606106-42232859 mg/L - milligrams per liter (ppm); ug/L micrograms per liter (ppb) MRL = Minimum Reporting Limit; BDL = Below Detection Limit; * = Comment applied "GL = Guideline Value; " "If you have any questions about how your results may impact your health, please contact Toxcall at 303-692-2606 or cdphe_toxcall@state.co.us" EPA provisional certification for methods 200.8,300.1, 504.1, 505, 524.2, 525.2, 531.2, 547, 548.1, 549.2, and 555. (EPA) - Method listed on EPA Safe Drinking Water Act (SDWA) accreditation. Visit https://cdphe.colorado.gov/laboratory-services/lab-accreditations to view certification status. Sample Results Lab ID:2409190075 Sample ID:263-38 Date Collected:09/18/2024 12:45 Date Received:09/19/2024 12:37 Sample Type:Water Description: Collection Site:WELL HYDRANT 132 RUSTY SPUR TR RIFLE CO 81650 Site Description: WELL HYDRANT 132 RUSTY SPUR TR RIFLE CO 81650 Parameter Results Units MRL GL DF Prepared Analyzed Qual EPA 9223B (Total Coliform and E. coli P/A) COLIFORM P/A PRESENT 1 09/20/2024 11:25 09/20/2024 11:25 * A COLIFORM P/A result of "PRESENT" indicates an unsafe sample, greater than or equal to 1 Coliform per 100mL. E. COLI P/A ABSENT 1 09/20/2024 11:25 09/20/2024 11:25 * An E.COLI P/A result of "ABSENT" indicates that E.coli was NOT DETECTED. ICP Total Water Metals (Metals, ICP-OES) Calcium 97.3 mg/L 0.1 1 10/05/2024 03:24 10/09/2024 11:49 Iron 0.169 mg/L 0.002 .3 1 10/05/2024 03:24 10/09/2024 11:49 Magnesium 19.3 mg/L 0.02 1 10/05/2024 03:24 10/09/2024 11:49 Sodium 1360 mg/L 4 20 10/16/2024 13:06 10/17/2024 10:11 ICP-MS Total Water Metals (Metals, ICPMS (EPA)) Arsenic 0.00247 mg/L 0.001 .01 1 10/02/2024 13:02 10/10/2024 17:27 Cadmium <0.001 mg/L 0.001 .005 1 10/02/2024 13:02 10/10/2024 17:27 Copper 5.27 ug/L 1 1300 1 10/02/2024 13:02 10/10/2024 17:27 Lead <1 ug/L 1 15 1 10/02/2024 13:02 10/10/2024 17:27 Manganese 18.4 ug/L 1 50 1 10/15/2024 18:25 10/16/2024 11:08 Uranium 0.00968 mg/L 0.001 .03 1 10/02/2024 13:02 10/10/2024 17:27 Zinc 21.7 ug/L 5 5000 1 10/15/2024 18:25 10/16/2024 11:08 * Q - Spike recovery below quality control acceptance limits due to possible matrix interference. All other quality control standards acceptable. Inorganic Anions (Anions, IC (EPA)) Fluoride 2.62 mg/L 0.5 1 10/12/2024 12:00 10/12/2024 12:00 Chloride 1370 mg/L 0.5 250 1 10/12/2024 12:00 10/12/2024 12:00 * Chloride result exceeds the National Secondary Drinking Water Standards limit. Potential symptoms include salty tastes, corroded pipes, fixtures, and appliances, blackening and pitting of stainless steel. Sulfate 1450 mg/L 0.25 250 1 10/12/2024 12:00 10/12/2024 12:00 * Sulfate result exceeds the National Secondary Drinking Water Standards limit. Potential symptoms include bitter medicinal taste, scaly deposits, corrosion, laxative effects, rotten egg odor from hydrogen sulfide gas formation. Analysis Report Colorado Department of Public Health and Environment 8100 Lowry Blvd. Denver, CO 80230 Tel: 303-692-3090 Fax: 303-344-9989 Workorder:4606106 Chemistry Testing Packages POWERED BY v.13.1.0 Report ID: Friday, November 1, 2024 12:44:21 PM 4606106-42232859 mg/L - milligrams per liter (ppm); ug/L micrograms per liter (ppb) MRL = Minimum Reporting Limit; BDL = Below Detection Limit; * = Comment applied "GL = Guideline Value; " "If you have any questions about how your results may impact your health, please contact Toxcall at 303-692-2606 or cdphe_toxcall@state.co.us" EPA provisional certification for methods 200.8,300.1, 504.1, 505, 524.2, 525.2, 531.2, 547, 548.1, 549.2, and 555. (EPA) - Method listed on EPA Safe Drinking Water Act (SDWA) accreditation. Visit https://cdphe.colorado.gov/laboratory-services/lab-accreditations to view certification status. Sample Results Inorganics (D 3739-83) Corrosivity -0.633 1 10/17/2024 05:12 10/17/2024 05:12 * The Corrosivity Index is < -0.5, which indicates that the water is considered aggressive and may deteriorate plumbing. A temperature of 15 degrees Celsius (59 degrees Fahrenheit) has been assumed for the calculation of Corrosivity. Corrosivity is temperature dependent and will increase with an increase in water temperature. Inorganics (Dissolved solids, Gravimetric) Dissolved Solids 4700 mg/L 10 500 1 09/20/2024 13:20 09/20/2024 13:20 * Total Dissolved Solids result exceeds the National Secondary Drinking Water standards limit. Potential symptoms include hardness or scaly deposits, sediment, cloudy or colored water, odor, staining, salty or bitter taste. Inorganics (Metals, ICP-OES) Hardness by SM 2340B 323 mg/L as CaCO3 1 80 1 10/05/2024 03:24 10/09/2024 11:49 * The hardness result indicates hard water. Potential symptoms include scaly residues and soap scum, decreased cleaning action of soaps and detergents. Inorganics (NA) Sodium Adsorption Ratio 32.9 mg/L 1 10/28/2024 06:43 10/28/2024 06:43 * A Sodium Adsorption Rate (SAR) of >25: Generally unsuitable for irrigation use. Inorganics (Nitrate-Nitrite, FIA) Nitrate-Nitrite (N)148 mg/L as N 0.05 10 10 09/24/2024 11:43 09/24/2024 11:43 * Nitrate-Nitrite (as Nitrogen) result exceeds the Maximum Contamination Limit. Infants below the age of six months who drink water containing Nitrate-Nitrite in excess of the MCL could become seriously ill and, if untreated, may die. Potential health effects include shortness of breath and blue-baby syndrome. Inorganics (SM 2320 B) Alkalinity Total 160 mg/L as CaCO3 20 1 09/26/2024 13:23 09/26/2024 13:23 Inorganics (SM 2510B) Conductivity 7000 us/cm 10 1 09/26/2024 13:23 09/26/2024 13:23 Inorganics (SM 4500-H+B) pH 7.03 Units 0.1 8.5 1 09/26/2024 13:23 09/26/2024 13:23 * pH Holding Time: This test is considered out of holding time due to pH being a field test. TL 9/27/24 Additional Information NON-SDWIS Free Chlorine (mg/L) Total Chlorine (mg/L) Collection Temp (C) Temp at Receipt (C)3.3 Water Type NEW WELL Analysis Report Colorado Department of Public Health and Environment 8100 Lowry Blvd. Denver, CO 80230 Tel: 303-692-3090 Fax: 303-344-9989 Workorder:4606106 Chemistry Testing Packages POWERED BY v.13.1.0 Report ID: Friday, November 1, 2024 12:44:21 PM 4606106-42232859 mg/L - milligrams per liter (ppm); ug/L micrograms per liter (ppb) MRL = Minimum Reporting Limit; BDL = Below Detection Limit; * = Comment applied "GL = Guideline Value; " "If you have any questions about how your results may impact your health, please contact Toxcall at 303-692-2606 or cdphe_toxcall@state.co.us" EPA provisional certification for methods 200.8,300.1, 504.1, 505, 524.2, 525.2, 531.2, 547, 548.1, 549.2, and 555. (EPA) - Method listed on EPA Safe Drinking Water Act (SDWA) accreditation. Visit https://cdphe.colorado.gov/laboratory-services/lab-accreditations to view certification status.