HomeMy WebLinkAboutConditions of PermitCONDITIONS OF PERMIT
BLRE-O1-25-9057
ROBERT & MARY SCHOOFS TRUST
New Single-family dwelling w/ attached garage
285 Hidden Valley Dr, GWS
SPRINGRIDGE RESERVE PUD, Phase 4, LotT 4
1) ALL WORK SHALL COMply W|TH THE 201s TNTERNATTONAL RESTDENTIAL CODE (l.R.C.)AND 2018
I NTERNATIONAL ENERGY CONSERVATION CODE (I.E.C.C.)
2) PROPOSED IMPROVEMENTS ARE SUBJECT TO ALL APPLICABLE ITEMS CONTAINED IN THE
ATTACHED "GARFIELD COUNry BUILDING REOUIREMENTS". NUMBER REFERENCES NOTED ON
PLANS REFER TO SPECIFIC ITEMS ON THIS LIST.
3) ELECTRTCAL pERMtTTtNG AND tNSpECTIONS BY COLORADO STATE ELECTRIC BOARD. ELECTRICAL
ROUGH-IN APPROVAL IS REOUIRED AT FRAME INSPECTION. ELECTRICAL FINAL APPROVAL IS
REOUIRED FOR FINAL INSPECTION & CERTIFICATE OF OCCUPANCY.
4) ALL EXTERIOR LIGHTING TO BE DOWNCAST AND SHIELDED.
5) WILDFIRE MITIGATION RECOMMENDATIONS: SHOULD COMPLY WITH WILDFIRE MITIGATION AND
DEFENSIBLE SPACE RECOMMENDATIONS PER COLORADO STATE FOREST SERVICE AND LOCAL FIRE
DISTRICT. PLEASE REFER TO THE GARFIELD COUNTY COMMUNIry DEVELOPMENT WEBSITE FOR
ADDITIONAL I NFORMATION.
6) OPEN HOLE SOTLS REPORT tS REOUTRED AT FOOTTNG TNSPECTTON AND PR|OR TO ANY CONCRETE
POUR. PROVIDE COPY OF GEOTECHNICAL ENGINEERS REPORT TO THE BUILDING INSPECTOR.
1,500 PSF soil bearing.
7) A LOT TMPROVEMENT CERT|FTCATE, SEALED BY A COLORADO LTCENSED SURVEYOR, lS REOUIRED AT
FOUNDATION INSPECTION TO VERIFY STRUCTURE _ INCLUDING PROPOSED ROOF OVERHANGS,
DECKS AND OTHER PROJECTIONS - IS IN COMPLIANCE WITH THE MINIMUM SETBACK AND/OR
BUILDING ENVELOPE REOUIREN4ENTS.
8) RESTDENTTAL DEStcN GRAPHTCALLY DEPTCTS FTNTSHED LIVING SPACE OF 2,290 SO FT PLUS 778 SO
FT ATTACHED GARAGE AND 166 SO FT COVER PATIO PROJECTIONS FOR TOTAL'FIRE AREA' = 3,234
SO FT. TOTAL'FIRE AREA' IS LESS THAN 3,600 SO FT. SUBMITTED DESIGN DOES NOT NEED TO BE
FIRE.SPRINKLERED PURSUANT TO SUBDIVISION RECORDED PLAT NOTES.
9) BLOWER DOOR TEST tS REQUTRED. MUST SUBMTT BLOWER DOOR TEST REPORT TO GARFIELD
COUNTY COMMUNITY DEVELOPMENT DEPT. OFFICE PRIOR TO SCHEDULING FINAL BUILDING
INSPECTION / C.O. FINAL.
10) PRESCR|pTtVE PATH USrNG 2018 rECC TABLE R402.1.2 rS CHOSEN FOR ENERGY COMPLIANCE OF
THIS HOME, MANUAL J REPORT ALSO ATTACHED FOR REFERENCE. ALL NEW HOMES TO HAVE
WHOLE-HOUSE MECHANICAL VENTILATION SYSTEM INSTALLED (201s IRC TABLE m1507.3.3(1)AND
(2)SHOWN ON COVER SHEET.
..e,I
hstt
-T
ss