Loading...
HomeMy WebLinkAboutConditions of PermitcoNDlilo NS OF PERMIT BLRE -12-24-90 40 MR. DREW TAYLOR 168 sq ft Residential Addition includes interior / exterior renovations to original 1984 single-family residence 310 Flying Fish Rd, Carbondale - 239132200032 1) ALL WORK SHALL COMPLY WITH THE 2015 INTERNATIONAL RESIDENTIAL CODE (I.R.C.)AND 2018 I NTERNATIONAL EN ERGY CONSERVATION CODE ( I.E.C.C.) 2) PROPOSED IMPROVEMENTS ARE SUBJECT TO ALL APPLICABLE ITEMS CONTAINED IN THE ATTACHED "GARFIELD COUNTY BUILDING REOUIREMENTS". NUMBER REFERENCES NOTED ON PLANS REFER TO SPECIFIC ITEMS ON THIS LIST. 3) ELECTRICAL PERMITTING AND INSPECTIONS BY COLORADO STATE ELECTRIC BOARD. ELECTRICAL ROUGH-IN APPROVAL IS REOUIRED AT FRAME INSPECTION. ELECTRICAL FINAL APPROVAL IS REOUIRED FOR FINAL INSPECTION & CERTIFICATE OF OCCUPANCY. 4) ALL EXTERIOR LIGHTING TO BE DOWNCAST AND SHIELDED. 5) WILDFIRE MITIGATION RECOMMENDATIONS: SHOULD COMPLY WITH WILDFIRE MITIGATION AND DEFENSIBLE SPACE REOUIREMENTS OF THE COLORADO STATE FOREST SERVICE AND LOCAL FIRE DISTRICT. SEE GARFIELD COUNTY COMMUNIry DEVELOPMENT DEPARTMENT WEBSITE FOR FURTHER INFORMATION. 6) OPEN HOLE SOTLS REPORT REOUTRED AT FrRST FOOTTNG TNSPECTTON ,2,500 PSF SOIL BEARING CAPACIry. COMPACTION REPORT /FANY STRUCTURAL FILL PERTAINS. 7) NEW CMU CRAWL SPACE FOUNDATTON. MUST NOT GROUT CMU UNT|L FrRST INSPECTED BY GARFIELD COUNTY BUILDING INSPECTOR. HAVE REBAR COURSES, BOND BEAMS READY TO INSPECT. FOR ANY PARTIAL INSPECTION i INSTALLATION PHASING NEEDS PLEASE HAVE GENERAL CONTRACTOR COORDINATE WITH BUILDING INSPECTOR DURING THE PRE-CONSTRUCTION MEETING AND/OR FIRST FOUNDATION INSPECTION. 8) DEMOLTTTON OF tNTER|OR OR STRUCTURAL (WATER DAMAGED) FRAME CONDITIONS MAY HAVE COMMENCED PRIOR TO THIS BUILDING PLAN REVIEW / PERMIT ISSUANCE. IT SHALL REMAIN PRIVILEGE OF GARFIELD COUNTY BUILDING INSPECTOR -- BASED UPON OBSERVED AS-BUILT FIELD CONDITIONS -- TO REOUIRE PROPERry OWNER / BUILDER TO REMIT WET STAMPED DETAILS PREPARED BY MILLARD STRUCTURAL ENGINEERING. 9) BEDROOM 2 ',EXtSTtNG LOFT', NOT APPROVED FOR USE AS A BEDROOM OR HABITABLE LIVING -- LOFT IS NON-HABITABLE STORAGE ONLY. 10) NO CONSTRUCTTON PARKTNG / STAGTNG AREA OVER SEPTTC TANK / LEACH FIELD. 1 1) WORK UNDER THtS PERMtT tS LtMITED TO THE STNGLE-FAMTLY RESIDENCE ONLY. NO WORK lS PROPOSED TO ANY OTHER STRUCTURE ON THE LOT, SEPARATE BUILDING PERMITS AND/OR LAND USE CHANGE PERMITS WILL APPLY WITH NEW CONSTRUCTION OR CHANGE IN OCCUPANCY ON THE PROPERry. NEW WORK SHALL BE IN ACCORDANCE WITH BUILDING CODES AND LAND USE REGULATIONS IN EFFECT AT TIME OF FUTURE WORK. CURRENT / FUTURE LOT OWNERS ADVISED TO VIEW HISTORIC PERMITS: 01383, 1980 EXEMPTION, PERMIT 3030, PERMIT 3868. 121 02.06.2025 CONDtTtON FROM GARFIELD COUNTY PUBLIC HEAITH: The connection from the detached garage to the OWTS shall be disconnected/abandoned before scheduling final building inspection for the main 3-bedroom residence. lf the applicant desires to leave this connection in place, the applicant shall apply for a Garfield County Alteration OWTS permit and obtain the services of a qualified OWTS professionalto design an OWTS for the total number of bedrooms and meets current Garfield County OWTS Regulations. $ "* $ N