HomeMy WebLinkAboutConditions of PermitCOND ITIONS OF PER MIT
BLRE-11-24-8989
JUDY SPASSER
New Primary Residential dwelling w/ attached garage
&
744 sq ft ADU over the 3rd bay of garage
699 Wood Deer Drive, Carbondale
Wooden Deer Subdivision, Lot B
1 ) ALL WORK SHALL COMPLY WITH THE 2015 INTERNATIONAL RESIDENTIAL CODE (I.R.C.) AND 2018
I NTERNATI ONAL EN ERGY CON SERVATION CODE ( I. E.C.C.)
2) PROPOSED IMPROVEMENTS ARE SUBJECT TO ALL APPLICABLE ITEMS CONTAINED IN THE
ATTACHED "GARFIELD COUNTY BUILDING REOUIREMENTS". NUMBER REFERENCES NOTED ON
PLANS REFER TO SPECIFIC ITEMS ON THIS LIST.
3) ELECTRTCAL pERMtTTtNG AND TNSPECTIONS BY COLORADO STATE ELECTRIC BOARD. ELECTRICAL
ROUGH-IN APPROVAL IS REOUIRED AT FRAME INSPECTION. ELECTRICAL FINALAPPROVAL IS
REOUIRED FOR FINAL INSPECTION & CERTIFICATE OF OCCUPANCY.
4) ALL EXTERIOR LIGHTING TO BE DOWNCAST AND SHIELDED.
5) WtLDFIRE MITIGATION REOUIREMENTS AS PER PLAT NOTE 'l : SHALL COMPLY WITH WILDFIRE
MITIGATION AND DEFENSIBLE SPACE RECOMMENDATIONS PER COLORADO STATE FOREST SERVICE
AND LOCAL FIRE DISTRICT. CONTRACTOR TO REFERENCE ALL WILDFIRE NOTES ON SP-1.
6) OPEN HOLE SOTLS REPORT tS REOUTRED AT FOOTTNG TNSPECTION AND PRIOR TO ANY CONCRETE
POUR. PROVIDE COPY OF GEOTECHNICAL ENGINEERS REPORT TO THE BUILDING INSPECTOR.
1.500 PSF soil bearing.
7) PRE-ENGTNEERED ROOF TRUSSES. HAVE ENGTNEERTNG FOR BUILDING INSPECTOR AT TIME OF
FRAME INSPECTION.
S) SEPTIC SYSTEM REVIEW / APPROVALS: PRIOR TO BUILDING INSPECTION & CERTIFICATE OF
OCCUPANCY PROVIDE FINAL APPROVAUSIGN-OFF FROM GARFIELD COUNTY'S PUBLIC HEALTH
DEPT.
9) RETAINING WALLS GREATER THAN 4-FT HEIGHT SHALL BE ENGINEERED AND SEALED BY A
COLORADO LICENSED DESIGN PROFESSIONAL.
1O) BLOWER DOOR TEST IS REOUIRED FOR EACH DWELLING UNIT. MUST SUBMIT TWO (2) BLOWER
DOOR TEST REPORTS TO GARFIELD COUNTY COMMUNITY DEVELOPMENT DEPT. OFFICE PRIOR TO
SCHEDULING FINAL BUILDING
1 1 ) PRESCR|pTtVE PATH USTNG 2018 tECC TABLE R402.1.2 lS CHOSEN FOR ENERGY COMPLIANCE OF
THIS HOME. MANUAL J REPORT ALSO ATTACHED FOR REFERENCE. ALL NEW HOMES TO HAVE
WHOLE-HOUSE MECHANICAL VENTILATION SYSTEM INSTALLED (2015 IRC TABLE M1507.3.3(.I)AND
(2)SHOWN ON COVER SHEET.
$
aI
$\
.\
d