HomeMy WebLinkAboutInstallation Observation Letter
5020 County Road 154
Glenwood Springs, CO 81601
phone: (970) 945-7988
fax: (970) 945-8454
email: kaglenwood@kumarusa.com
www.kumarusa.com
Office Locations: Denver (HQ), Parker, Colorado Springs, Fort Collins, Glenwood Springs, and Summit County, Colorado
January 17, 2025
Puma Paw, LLC
Attn: John Hildebrant
1793 County Road 219
Rifle, Colorado 81650
jhilderbrant42@gmail.com
Project No. 23-7-190.02
Subject: Certification of Onsite Wastewater Treatment System, Proposed Residence,
1793 County Road 219, Garfield County, Colorado
Dear John:
A representative of Kumar & Associates observed the installation of the Onsite Wastewater
Treatment System (OWTS) for the ADU at the subject site as required by the Garfield County
Environmental Health Department. Our observations and recommendations are presented in this
report. The services are supplemental to Kumar & Associates agreement for professional
services to you dated March 15, 2023.
We previously designed the OWTS for the Residence as submitted in our report dated July 17,
2023, Project No. 23-7-190.02. The system was designed for three bedrooms.
We performed our as-built evaluation on July 12 and 22, 2024. The OWTS components
observed included: sewer line, cleanout, septic tank, distribution box, effluent line and soil
treatment area (STA) and the locations of these components. The installation and locations of
the system components were verified as shown on Figure 1. Pictures of the OWTS components
made during the site visit are included with this report. The distance locations to the septic tank
shown on Figure 1 were made by taping.
The septic tank was changed from a Valley Precast 1,000-gallon, two-chamber tank to a
Norwesco 1,500-gallon, two-chamber tank. The Infiltrator Quick4 Plus standard chambers were
changed to Infiltrator H-20 chambers. The Tuf-tite 4-Hole distribution box was changed to a
concrete 8-hole distribution box. The changes are acceptable to us.
On July 12, 2024, an additional profile pit (Profile Pit 3) was excavated at the location shown
on Figure 1. The soils in Profile Pits were similar to the soils previously encountered in Profile
Pits 1 and 2. Below about 1 foot of organic topsoil, the soils consisted of Sandy Loam to the pit
depth of 8 feet. No Free water was encountered in the pit nor indications of seasonally high
groundwater were observed at the time of excavation.
It is our opinion that the OWTS was installed in general conformance with the above referenced
design.
Kumar & Associates
OWTS PHOTOGRAPH LOG
PROPOSED RESIDENCE
1793 COUNTY ROAD 219
GARFIELD COUNTY, COLORADO
Project No. 23-7-190.02
Photograph 1: Cleanout and
sewer line exiting building.
Photograph 2: Norwesco 1,500-
gallon, two-chamber septic tank.
OWTS PHOTOGRAPH LOG
PROPOSED RESIDENCE
1793 COUNTY ROAD 219
GARFIELD COUNTY, COLORADO
Project No. 23-7-190.02
Photograph 3: Norwesco 1,500-
gallon, two-chamber septic tank
nameplate.
Photograph 4: Effluent filter at
septic tank outlet
OWTS PHOTOGRAPH LOG
PROPOSED RESIDENCE
1793 COUNTY ROAD 219
GARFIELD COUNTY, COLORADO
Project No. 23-7-190.02
Photograph 5: Sewer line from
residence to septic tank.
Photograph 6: Effluent line
from septic tank to distribution
box.
OWTS PHOTOGRAPH LOG
PROPOSED RESIDENCE
1793 COUNTY ROAD 219
GARFIELD COUNTY, COLORADO
Project No. 23-7-190.02
Photograph 7: 8-hole concrete
distribution box.
Photograph 8: Soil treatment
area (STA)