Ted White
Garfield County Public Health
2014 Blake Ave.
Glenwood Springs, CO 81601
970-945-6614
RE Onsite Wastewater Treatment System Tank Replacement for Behlow Project located at 89
Fairway Ln., Glenwood Springs, CO 81601
On April 11,2024, K-Cronk Engineering, Inc. had a meeting with the owner of the property
mentioned above to discuss the Onsite Wastewater Treatment System servicing the existing five-
bedroom residence. According to the records obtained from Garfield County, the system consists
of a 1,25}-gallon aeration tank, followed by a 15'x15' seepage pit. The owner advised K-Cronk
Engineering, Inc. that the existing tank shows signs of damage and has been leaking over time and
requires replacement.
The existing tank must be pumped to remove as much waste as possible. The bottom, top, and
sides must be crushed in to ensure the tank neither floats nor fills with watet, and the remaining
void must be filled with gravel, sand, or compacted soil.
The owner may wish to add up to three bedrooms to their existing residence in the future. The
owner would like to plan for this expansion now and size the replacement tank so it may
accommodate the eight bedrooms. The existing seepage pit is not large enough to accommodate
anv exnansro and will need to be in full when the addition constructed.
To accommodate both the existing and future bedrooms, the following tank configuration is
proposed:
A 1,500-gallon, single compartment septic tank will be used as a settling tank for all solids. A non-
corrodible Orenco filter (model # FTW0436-28, or equivalent) shall be installed at the outlet tee
of the septic tank to limit the size of solids and sludge passing through. The filter must be accessible
for cleaning and replacement from the ground surface. A 1,000-gallon, single compartment septic
tank will be placed down-gradient of the 1,50O-gallon tank. The combined volume of these two
N
$
N=
tanks will provide a minimum of 48-hours retention time for sewage generated by the proposed
project.
The tanks are shown in the enclosed graphic. Installer mals adjust the location andlor orientation
as needed to existins site condi and offsets. The elevations of the existing septic
tank and effluent lines are currently unknown. Should existing conditions limit the feasibility of
replacing the tank while still maintaining gravity flow to the seepage pit, a pressurized system
mav be required. It is the owner's/installer's responsibility to inform this office of any issues
once the elevations have been determined.
LIMITS
This letter is a site-specific design for installation of a replacement tank and is applicable only for
the client for whom our work was performed.
The recommendations and design guidelines outlined in this letter are based on: 1) the proposed
site development and plot plan as furnished to K-Cronk Engineering, Inc. by the client, and 2) the
site conditions disclosed at the specific time of the site investigation of reference. K-Cronk
Engineering, Inc. assumes no liability for the accuracy or completeness of information furnished
by the client. Site conditions are subject to external environmental effects and may change over
time. Use of this plan under different site conditions is inappropriate. If it becomes apparent that
current site conditions vary from those anticipated, the design engineer and Garfield County should
be contacted to develop any required design modifications. K-Cronk Engineering, Inc. is not
responsible and accepts no liability for any variation in assumed design parameters.
The construction of all OWTS components must be done according to the currently adopted
OWTS regulations for Garfield County
K-Cronk Engineering, Inc. represents this letter has been prepared within the limits prescribed by
the owner and in accordance with the current accepted practice of professional engineering in the
area. No warranty or representation, either expressed or implied, is included or intended in this
report or in any of our contracts.
Seal
,e Crrt6
Kachayl Cronk, P.E
P.O, Box 140
Mack, CO 81525
9'.70-250-0572
Enc
Tank Replacement Plan
Garfield County Record
NITE
THE FELLEVING SETBACKS MUST BE MAINTA]NENI
SEPTICTANK STA
SPRINGS/VELLS
-
50/
LAKE/STREAM,/IRRIG! NiTCH-5Oi
INTERI'IITTENT IRR]G, DITCH-10/
SELID PIPEILINED DITCH
DIMESTIC VATER CISTERN
-
50'
D0MESTIC VATER LINE
-
10/
STRUCTURE V/CRAVLSPACE
-
5/
STRUCTURE V,/ECRAVLSPACE-5'
PRDPERTY LINE
-
10,
100'
50'
?5',
10'
100'
?5',
?0'
10'
10'
10'GATED PIPE
oreo oF --\ -/<reference \2z,/-/
i.r
\
opprox. location of
exlsting tank (to b
abondoned ln place)
e
opprox,
exlstlng
locotion of
seepo.g
uded in
e plt(not incI scope
of deslgn)
NDTE
INSTALLER MAY CHANGE
ERIENTATi[N/L!CAT]EN NF
TANKS AS NEEDED TE
MAINTAIN ELEVAT]IN AND
IFFSETS.
\
b'
, ,ih,
1,000 gotton, singte
conpontnent
septic tonk
1,500 gotton,
con portnenttic tanksepefftuent fltten
N!TE
THE EXISTING TANK MUST BE
PUMPED TE REMIVE AS MUCH
VASTE AS POSSIBLE. THE BETTDM,
TEP, ANI SIDES I4UST BE
CRUSHED IN TE ENSURE THE TANK
NEITHER FLIATS NlR FILLS VITH
\./ATER, AND THE REMAINING VDIN
MUST BE FILLED VITH GRAVEL,
SAND, [R CEMPACTED S!]L,
out exlstlng
nesidence
NOTE
CALL 811 FNR UTILITY LECATES
i
APRIL 16, 2OA4
SCALE' 1'=20'NI]RTH
PRDJECT
FAIRVAY LANE
-02-032
LAYEUT PLAN
.ill
a f" "e;b This does not constitute
a buildins or use permit..1
!
GARFIELD COUNTY DEPARTMENT OF ENVIRONMENTAL HEALTH
2o1A Blaks Avenue
Glonwood Springs, Colorado 81001
PErcHAIVEO - FET ONLY
INDIVIDUAL SEWAGE DISPOSAL PERMIT Ht s6$
Ken llalby
, !r-
Owner
32 ?nd Flll sSystem Location
own€r
'",
illll
rti[ti
li:l
rii'..
iil'
rlrt:
lll. r
l:,1.
ilJr!
iil:i
ilt,,
iiilril'i.
ti&
ir[
lilf 'l
liir
iE:
lil
:ilr:'
riii,!.
tlir.
t!L,l
:r:ir '
ii'
;Ji
Itill
:fl
Ii!...
i'i",
lill!,,,
liiirr
il|,r
iiii
'l':
!!,i
i'ir:
.ri
,!:
i!,.
i'i,:
ti
:,ii
iii'
lrii
iii
i:l
;:!.
l
!l:i
;:t.j
lilrr
rii
*,
iir'
rli,
::i
ltii
ri!;
i:,,
I
ri,lr'i
,:ii,
,i:,
:
':,
::..
::
Llcensed Contractor
' Conditional Construction approval is hereby granted for a 1.250 gal I on
Septic Tank or X Aerated treatment unit'
Absorption area (or diapersal area) computed as lollows:
Perc rats of one inch in - 5 minutes requires a minimum of of absorption area oer bedroom.
a totarof =- ;rt. of absorption arsa,
125 cn It.
Therefore the no. of bedrooms 5 x I ?5 sq. ft, minimum requirement =
May wesussest I 14' square and '15' deep DEHP FIELD (l2r of
Date Anrll ?2. 1976 lnspector
FINAL APPROVAL OF SYSTEM:
No system shall be deemed to be in compliance with the Sewage Oisposal Laws until the assembled syslem is approved prior tocovsr.
ing any part.
. 4+ ffi^nucleanout to within 12" of tinal grado or aer€ted access ports above grade.
a*6.-Proper materials and assembly.
- 4 *Trade name of septic tank C-T-?:,
&/
Adequate absorption (or dispersal) area.
Adequate compliance with permit requirements,
Adequate compliance with County and $tate regulations/requirements.
Other
&z--
Date 4*E -2b lnspector
RETAIN WITH RECEIPT RECORDS AT CONSTRUCTION SITE
ICONDITIONS:
1. All installation .nust comply with all requirements of the County lndividual $ewage Disposal Regulations, adopted pursuant lo 8u'
thority granted in 66-44'4, CRS 1963, amended 66'3'14, CRS 1963,
2, This permit is valid only for connection to $tructures which have lully complied with County Zoning and building requirements.
Connection to or use with any dwelting or structures not approved by the building and Zoning office shall automatically be a viola'
tion of a requirement of the permit and cause for both ligal action and revocation of the permit.
3. Section 111,3,24 requiros any person who constructs, $lters, or installs an individuat $€wage disposal system in a manner which ln'
volves a knowing and materi6l variation from the terms or spoci{ications contained in the application of permit commits a Class l,
Petty Offense ($500.00|ine - 6 months in jail or both. ,
Buitding Official - Permit White Copy Applicant - Green Copy Dspt. - Pink Copy
aggregrte nd leach llne).
.':
aerated treatment un
ji--. -.--r..g -rrra. i &.r.^rdi. -lJiiilrrrrrgrt..
' -9tr9Fees Paid $-.?S'
oa*4-.>eINDIVIDUAL SEWAGE DISPOSAL SYSTEMS APPLICATION
" NofiFIcATIoN 0F pRoposED DIscHARcE T0 l,tATERs 0F THE srATE
INDIVIDUAL HOME sEI^IAGE TREATf."IENT SYSTEM
J
0wner:
Hail Address:City:
NFORMTION RTGARDING PROJECT SUBMITTED FOR REVIEI.J
p, .{ftat.phone ' t<{8_
with respect to surrounding areas,
potabl e water wel I s , soi'l percol a-
LI ty or Town
of Size
Aer a t on Unit Capacity 4r2-
Attach separate sheets or report showing enti
topography of area, habitable buildings, loca
tion test holes, soil profiles in test holes.
'1. Location of faci'l
tegal Description
2. No. of Bedrooms
I ty: Cou
Septic Tan Capac.'i
re area
tion of
4
3. Source of Domestic Water: Public (nane):
Private: Well
--_
Depth 0ther *-'--_ Dep to first ground water table
Is facility within boundaries of a city/town or sanitation district?&).rc -
Distance to nearest sewer system:
4
5 ?
Have you attempted to arrange a connection with the system?
If rejected, what was the reason?
6.
7. Name, addressr ihd telephone of person who made soil absorption tests:
8. Name,dress, and telephone of person responsib'le for design of the system:
Rate of absorption in test holes shown on the 'location map, in minutes per inch of
drop in water Jevel after holes have been soaked for ?4 hours:
9 Express
mernber o
they may
acknowl e
the
desi
dged
ssion-is.hereby granted for the inspection of the above property by anyGarfield County Environmental Health Department and/or such persons asgnate. Any withdrawal of this permission shall be in wrlting.and receipt
by the County Environmental Health Department.
10.Ih
Gar
inc
ave been given an opportunity to read the Individual Dlsposal Systems Regulations offield County and I hereby agree to comply with all terms, conditions and requirements
Iuded therein.
a
2
(T0 BE RTTURNED T0 HEALTH DEPT.)
gn e
PLEASE DRAI.I AN ACCURATE MAP TO YOUR PROPERTY
a
I
\t ll
?
ts [l-
l.-,4:"..fa
k tTroIlft tf fT,ft /,
Wu,fl"n
0
J^,r 9 L
INDI BELOW THE LOCATION OF Y BUILDII.IGS I^IATER PPLY AND DISTRI-
(T0 BE RETURNED T0 HEALTII DEPT. )
Be$low Prciect
89 FairwaY lane
Glenwood SPrings, CO BI60I
Parcel No. 239 5 -OZI -02-032
The onsite wastewater treatment system of reference was inspected on May 16,2024' The
system was found to conform with the plans and specifications set forth in the engineered
sewage disposal system design for the aforementioned property prepafed on May 16,2024'
Swimming pools, ponds, or other water features were not included in the submitted or approved
design. Sitta* oiOWTS components from property lines and easements are based on
infoimation provided by owner or owner's repreientative- .Soil cap and final grading.associated
with any OWTS oomponents are not included in this certification. Copies of the engineered plan
are on file at the Mesa County Building Department or may be obtained from the undersigned
design engineer.
K-CROATT(P.O. Bo.t r4o
:Ustft, CO
g7o,z5tt,o17z f ft a ch att l. a. cr rnl h @ o u tlo ok. L'. o,r t
Ce*ificate of Inspection 8c Acceptance
May 16,2024
E
Seal
Cronk, P.E.
P.O, Box 140
Mack, CO 81525
970-250-0572
A fl\
6il40 =
Noter Property [nes oregneoter thon 100'frot'r
solt treotnent oreo unless
otherwlse hoted
Noter Exlstlng septlc tonkros renoved, not
obondoned
of cleslgn
7,4',
cleon
out {
ru
1,000 gotlon
septlc tonk
I
1,500
(
!,{\o
-t
o!.a.o5no
t_
septlc tonk
renoved
BEHLI]V PRBJECT
89 FAIRVAY LANE
a395-0a1-02-032
ASBUILT I'RAVIN6
MAY 16, 20e4
SCALET 1'=20'NORTH