HomeMy WebLinkAboutHigh Strenth Bolt Inspection ReportConklin Welding & Fabrication, INC.
1188 CR 116
Glenwood Springs, CO 81601
C: 231.629.6252
Inspection Report
Date of Inspection:07January2024
Project Name: McDermott Residence
Job Site Address: 5322 CR 243, New Castle, CO
Permit/Drawing#: BLRE-09-24-8897
Welding Contractor: Garcia's Welding
General Contractor: J Martinez and Co
Inspection Type: Periodic Weld Inspection
Inspection Narrative
Inspection Report:
Onsite inspection of previously welded connections. Inspection included column to base plate, web
stiffeners, intermittent MC channel to beam stiffener. Inspection also included verification of welder
qualification, welding process, joint prep, interpass clean and final visual inspection.
To the best of my knowledge all aspects of weld appear to comply with D1.1 2020
Inspector: Eric Conklin-CWI QC1 21052071
//���¢ n/V1Ry 1" b7
n�/ C 2 052 1
CC1 EXP. 5/1/2027
Page 1 of 1
Conklin Welding and Inspection, Inc. 1-15-2025
Glenwood Springs, CO 81601
ATTN: Mr. Eric Conklin
RE: 5322 CR 243
New Castle, CO
*Field Inspection
Dear Mr. Conklin,
As requested, structural steel special inspection was conducted per the IBC 2021
Edition - Chapter 17: Structural Tests and Special Inspection and the Garfield County
requirements. I arrived on -site at 9:30 AM. I met with Mr. Tyler Miles to review the
material to be inspected and project requirements.
High strength bolt inspection was conducted on the picture window frame on the
side of the residence. I observed all bolts for this frame that were specified to be
pretensioned. I observed Mr. Miles pretension procedure torquing the bolts to the proper
amount. I observed all bolts to be 3/4" ASTM A325 plain body bolts fitted with hardened
flat washer properly positioned under the turning surface of a heavy hex bolt. Upon
completion, I observed all bolts to be in compliance with project specifications and the
inspection criteria of the American Institute of Steel Construction (AISC) and the
Research Council on Structural Connections (RCSC).
Respectfully submitted,
Ak 4L�"'k�
Dan Bricker, CWI
AWS CWI #09052051W
Monument Steel Inspection
® Dani i L er
AWs C
Q X . 5/1/2027
Monument Steel Inspection, LLC 318.469.2279
PO Box 23388 monumentsteelinspectionlic22@gmail.com
Glade Park, CO 81523