Loading...
HomeMy WebLinkAboutHigh Strenth Bolt Inspection ReportConklin Welding & Fabrication, INC. 1188 CR 116 Glenwood Springs, CO 81601 C: 231.629.6252 Inspection Report Date of Inspection:07January2024 Project Name: McDermott Residence Job Site Address: 5322 CR 243, New Castle, CO Permit/Drawing#: BLRE-09-24-8897 Welding Contractor: Garcia's Welding General Contractor: J Martinez and Co Inspection Type: Periodic Weld Inspection Inspection Narrative Inspection Report: Onsite inspection of previously welded connections. Inspection included column to base plate, web stiffeners, intermittent MC channel to beam stiffener. Inspection also included verification of welder qualification, welding process, joint prep, interpass clean and final visual inspection. To the best of my knowledge all aspects of weld appear to comply with D1.1 2020 Inspector: Eric Conklin-CWI QC1 21052071 //���¢ n/V1Ry 1" b7 n�/ C 2 052 1 CC1 EXP. 5/1/2027 Page 1 of 1 Conklin Welding and Inspection, Inc. 1-15-2025 Glenwood Springs, CO 81601 ATTN: Mr. Eric Conklin RE: 5322 CR 243 New Castle, CO *Field Inspection Dear Mr. Conklin, As requested, structural steel special inspection was conducted per the IBC 2021 Edition - Chapter 17: Structural Tests and Special Inspection and the Garfield County requirements. I arrived on -site at 9:30 AM. I met with Mr. Tyler Miles to review the material to be inspected and project requirements. High strength bolt inspection was conducted on the picture window frame on the side of the residence. I observed all bolts for this frame that were specified to be pretensioned. I observed Mr. Miles pretension procedure torquing the bolts to the proper amount. I observed all bolts to be 3/4" ASTM A325 plain body bolts fitted with hardened flat washer properly positioned under the turning surface of a heavy hex bolt. Upon completion, I observed all bolts to be in compliance with project specifications and the inspection criteria of the American Institute of Steel Construction (AISC) and the Research Council on Structural Connections (RCSC). Respectfully submitted, Ak 4L�"'k� Dan Bricker, CWI AWS CWI #09052051W Monument Steel Inspection ® Dani i L er AWs C Q X . 5/1/2027 Monument Steel Inspection, LLC 318.469.2279 PO Box 23388 monumentsteelinspectionlic22@gmail.com Glade Park, CO 81523