HomeMy WebLinkAboutConditions of PermitCONDITION 50 F PERMIT
BLCO-02-25-9095
THUNDER RIVER MARKET
INTERIOR KITCHEN REMODEL
6818 HIGHWAY 82
PARCEL NUMBER: 239501 400139
1) THE APPROVED PLANS ARE TO BE ON-SlrE FOR INSPECTIONS.
2) SANTTARY FACILITIES ARE REOUIRED TO BE PROVIDED FOR WORKERS.
3) A LIST OF REOUIRED INSPECTIONS WILL BE ATTACHED TO THE PLANS. THE STATE
IS TO PERMIT AND APPROVE THE ELECTRICAL WORK.
RMITS
4) ELECTRICAL CODE COMPLIANCE WILL BE DETERMINED BASED ON FIELD
INSPECTIONS PERFORMED BY THE STATE ELECTRICAL INSPECTOR, (303) 869-3458.
PLEASE HAVE THE INSPECTOR SIGN THE BUILDING CARD OR PROVIDE WRITTEN
DOCUMENTATION OF THE INSPECTIONS.
5) ALL ACCESSIBLE DOOR HARDWARE SHALL HAVE A SHAPE THAT IS EASY TO GRIP,
INCLUDING POCKET AND SLIDING DOORS. (ANSI A117.1 - 404.2.6)
6) ALL FOOD SERVICE FACILITIES ARE TO BE LICENSED AND APPROVED BY GARFIELD
COUNTY ENVIRONMENTAL HEALTH DEPARTMENT. PROVIDE APPROPRIATE
APPROVAL PRIOR TO SERVING THE PUBLIC.
7) THE PROPOSAL FROM "HOODBUtLDER" lS INDICATING FLEX DUCT FOR THE MAKE-
UP AIR. THE 1015 IMC SECTION 506.3.1.2 STATES SPECIFIC SECTIONS OF CHAPTER
6 REOUIRING METAL DUCT MATERAIL WITHIN 18" OF THE HOOD.
8) TYPTCAL HOOD INSPECTIONS:
WELD INSPECTION, THE CONTRACTOR IS TO PROVIDE A HALOGEN OR 1OO-
WATT LIGHT. ALL WELDS ARE TO BE CHECKED WITH THE LIGHT TO VERIFY
THERE ARE NO LEAKS. IF LAPPED JOINTS ARE USED, A SMOKE TEST WILL BE
REOUIRED. CLEANOUT LOCATIONS WILL BE VERIFIED AT THAT TIME.
FIRE WRAP INSULATION. ryPICAL 2 LAYER SYSTEM ALLTAPING AND
STRAPPING TO BE IN PLACE FOR THE INSPECTION. PICTURES OF THE FIRST
WRAP LAYER IS PERMITTED.
HOOD FINAL: THE HOOD IS TO COME ON AUTOMATICALLY WHEN IT
SENCES HEAT. THE FIRE-SUPPRESSION INSTALLER ON-SITE, THEY REPLACE
THE SUPRESSION TANK WITH AN AIR TANK FOR THE TEST. THE HOOD IS
PUT UNDER ALARM, THE CAPS ON SUPPRESSION DISCHARGE, THE HOOD
a
a
a
Hood Builders lnc.
5925 E Evans Ave Suite 215
DENVER, CO 80222
+-13037777720
main.hoodbuilder@gmail.com
dtFlmdBUILNER
Estimate
ADDRESS
THUNDER nrVeA nlnnxrr
6818 CO-82 GLENWOOD SPRINGS
co 81 601
NATHAN 719-415-7278
NATHANJARELLANO@GMAIL.COM
zAcH@TCFUELS.COM
family of Nationwide cornpanies
SHIP TO
THUNDER RIVER MARKET
681B CO-82 GLENWOOD SPRINGS
co 81 601
NATHAN 719-415-7278
NATHANJARELLANO@
ZACH@TCFUELS.COM
FSTIMATE #
HBB2739A
SALES REP
.,oEL - 720-372-6729
ITTM #
HB1.) HOOD,
EXHAUST FAN, AND
MAU PACKAGE
HBz.) DUCT WORK
HBs") FrRE
SUPPRESSION
INSTALLATION
HB4.) ELECTRTCAL
INTERLOCKING
HB5.) ENGTNEERTNG
DRAWINGS AND
PERMIT PROCESS
Fr86.) ROOFING
HB7.) FIRE WRAP
DEMO
HB8.) STATNLESS
STEEL WALL
FLASHING
AUTOMATIC GAS
VALVE SHUT OFF
DATE
j O2l1gl2125
EXPINANON DATE
03t19t2025
DESCRIPTION
Hoods, Exhaust Fans, and a MAU
and install 13' x 4' Stainless Steel
and a Heated Make Up Air Unit. (U
Furnish
, Exhaust Fan,
NFPA
RATT
35,930.00
11,990.00
1 5,500.00
9,500.00
1 5,000.00
1 3,630.00
2,000.00
550.00
850.00
AMOUN-T
35,930.00
18,540.00
11,990.00
5,500.00
9,500.00
5,000.00
3,630.00
2,000.00
2,750.00
QTY
1
1 1 008,540.
complaint)
Furnish and lnstall 1 uct Work, MUA Duct
work,2 flat pieces,
straight path to the
:a,.$ln gl6!$tory H8lldind,
Furnish and lnstall Complete UL300 Compliant Fire
Suppression System lnstallation Chemical Bottle,
Control Head, CO2, PullStation, Chemical Line, and
Fusible Link line
Furnish and installControl Panel. Electrical
Connections for Hood, MAU, Microswitch Assembly,
and allsafety interlocks per NFPA and UL sequence
requirement (Not including the wiring to the units and
the Electrical Panel).
Mechanical, Electrical, and Fire System Drawings
including Permitting Process will be done by Customer
and the inspections will be done by Contractor.
Roof penetration and Roof patch (cold Patch) for ducts
penetration point.
Furnish and install Two layers of Fire Wrap for the
Grease Ducts.
Removal of existing 6'type 2 hood.
5 Sheets of stainless steel all flashing installed behind
the hood. Provided by the customer.
5
Furnish and install the automatic gas shut off valve 850.00