HomeMy WebLinkAboutConditions of PermitCONDITION 50 F PERMIT BLCO-02-25-9095 THUNDER RIVER MARKET INTERIOR KITCHEN REMODEL 6818 HIGHWAY 82 PARCEL NUMBER: 239501 400139 1) THE APPROVED PLANS ARE TO BE ON-SlrE FOR INSPECTIONS. 2) SANTTARY FACILITIES ARE REOUIRED TO BE PROVIDED FOR WORKERS. 3) A LIST OF REOUIRED INSPECTIONS WILL BE ATTACHED TO THE PLANS. THE STATE IS TO PERMIT AND APPROVE THE ELECTRICAL WORK. RMITS 4) ELECTRICAL CODE COMPLIANCE WILL BE DETERMINED BASED ON FIELD INSPECTIONS PERFORMED BY THE STATE ELECTRICAL INSPECTOR, (303) 869-3458. PLEASE HAVE THE INSPECTOR SIGN THE BUILDING CARD OR PROVIDE WRITTEN DOCUMENTATION OF THE INSPECTIONS. 5) ALL ACCESSIBLE DOOR HARDWARE SHALL HAVE A SHAPE THAT IS EASY TO GRIP, INCLUDING POCKET AND SLIDING DOORS. (ANSI A117.1 - 404.2.6) 6) ALL FOOD SERVICE FACILITIES ARE TO BE LICENSED AND APPROVED BY GARFIELD COUNTY ENVIRONMENTAL HEALTH DEPARTMENT. PROVIDE APPROPRIATE APPROVAL PRIOR TO SERVING THE PUBLIC. 7) THE PROPOSAL FROM "HOODBUtLDER" lS INDICATING FLEX DUCT FOR THE MAKE- UP AIR. THE 1015 IMC SECTION 506.3.1.2 STATES SPECIFIC SECTIONS OF CHAPTER 6 REOUIRING METAL DUCT MATERAIL WITHIN 18" OF THE HOOD. 8) TYPTCAL HOOD INSPECTIONS: WELD INSPECTION, THE CONTRACTOR IS TO PROVIDE A HALOGEN OR 1OO- WATT LIGHT. ALL WELDS ARE TO BE CHECKED WITH THE LIGHT TO VERIFY THERE ARE NO LEAKS. IF LAPPED JOINTS ARE USED, A SMOKE TEST WILL BE REOUIRED. CLEANOUT LOCATIONS WILL BE VERIFIED AT THAT TIME. FIRE WRAP INSULATION. ryPICAL 2 LAYER SYSTEM ALLTAPING AND STRAPPING TO BE IN PLACE FOR THE INSPECTION. PICTURES OF THE FIRST WRAP LAYER IS PERMITTED. HOOD FINAL: THE HOOD IS TO COME ON AUTOMATICALLY WHEN IT SENCES HEAT. THE FIRE-SUPPRESSION INSTALLER ON-SITE, THEY REPLACE THE SUPRESSION TANK WITH AN AIR TANK FOR THE TEST. THE HOOD IS PUT UNDER ALARM, THE CAPS ON SUPPRESSION DISCHARGE, THE HOOD a a a Hood Builders lnc. 5925 E Evans Ave Suite 215 DENVER, CO 80222 +-13037777720 main.hoodbuilder@gmail.com dtFlmdBUILNER Estimate ADDRESS THUNDER nrVeA nlnnxrr 6818 CO-82 GLENWOOD SPRINGS co 81 601 NATHAN 719-415-7278 NATHANJARELLANO@GMAIL.COM zAcH@TCFUELS.COM family of Nationwide cornpanies SHIP TO THUNDER RIVER MARKET 681B CO-82 GLENWOOD SPRINGS co 81 601 NATHAN 719-415-7278 NATHANJARELLANO@ ZACH@TCFUELS.COM FSTIMATE # HBB2739A SALES REP .,oEL - 720-372-6729 ITTM # HB1.) HOOD, EXHAUST FAN, AND MAU PACKAGE HBz.) DUCT WORK HBs") FrRE SUPPRESSION INSTALLATION HB4.) ELECTRTCAL INTERLOCKING HB5.) ENGTNEERTNG DRAWINGS AND PERMIT PROCESS Fr86.) ROOFING HB7.) FIRE WRAP DEMO HB8.) STATNLESS STEEL WALL FLASHING AUTOMATIC GAS VALVE SHUT OFF DATE j O2l1gl2125 EXPINANON DATE 03t19t2025 DESCRIPTION Hoods, Exhaust Fans, and a MAU and install 13' x 4' Stainless Steel and a Heated Make Up Air Unit. (U Furnish , Exhaust Fan, NFPA RATT 35,930.00 11,990.00 1 5,500.00 9,500.00 1 5,000.00 1 3,630.00 2,000.00 550.00 850.00 AMOUN-T 35,930.00 18,540.00 11,990.00 5,500.00 9,500.00 5,000.00 3,630.00 2,000.00 2,750.00 QTY 1 1 1 008,540. complaint) Furnish and lnstall 1 uct Work, MUA Duct work,2 flat pieces, straight path to the :a,.$ln gl6!$tory H8lldind, Furnish and lnstall Complete UL300 Compliant Fire Suppression System lnstallation Chemical Bottle, Control Head, CO2, PullStation, Chemical Line, and Fusible Link line Furnish and installControl Panel. Electrical Connections for Hood, MAU, Microswitch Assembly, and allsafety interlocks per NFPA and UL sequence requirement (Not including the wiring to the units and the Electrical Panel). Mechanical, Electrical, and Fire System Drawings including Permitting Process will be done by Customer and the inspections will be done by Contractor. Roof penetration and Roof patch (cold Patch) for ducts penetration point. Furnish and install Two layers of Fire Wrap for the Grease Ducts. Removal of existing 6'type 2 hood. 5 Sheets of stainless steel all flashing installed behind the hood. Provided by the customer. 5 Furnish and install the automatic gas shut off valve 850.00