Loading...
HomeMy WebLinkAboutConditions of PermitCONDITIONS OF PERMIT BLRE-06-24-8723 T&MEnterpriseLLC New Single-family dwelling on crawl / partially finish / unfinished basement 6534 CR 331, Silt-240111200218 1) ALL WORK SHALL COMPLY WITH THE 2015 TNTERNATTONAL RESTDENTTAL CODE (l.R.C.)AND 2018 r NTERNATTONAL EN ERGY CONSERVATTON CODE ( t. E.C.C.) 2) PROPOSED IMPROVEMENTS ARE SUBJECT TO ALL APPLICABLE ITEMS CONTAINED IN THE ATTACHED "GARFIELD COUNTY BUILDING REOUIREMENTS". NUMBER REFERENCES NOTED ON PLANS REFER TO SPECIFIC ITEMS ON THIS LIST. 3) ELECTRICAL PERMITTING AND INSPECTIONS BY COLORADO STATE ELECTRIC BOARD. ELECTRICAL ROUGH-IN APPROVAL IS REOUIRED AT FRAME INSPECTION. ELECTRICAL FINAL APPROVAL IS REOUIRED FOR FINAL INSPECTION & CERTIFICATE OF OCCUPANCY. 4) ALL EXTERTOR L|GHT|NG TO BE DOWNCAST AND SHtELDED. 5) WILDFIRE MITIGATION RECOMMENDATIONS: SHOULD COMPLY WITH WILDFIRE MITIGATION AND DEFENSIBLE SPACE RECOMMENDATIONS PER COLORADO STATE FOREST SERVICE AND LOCAL FIRE DISTRICT. PLEASE REFER TO THE GARFIELD COUNTY COMMUNITY DEVELOPMENT WEBSITE FOR ADDITIONAL I N FORMATION. 6) OPEN HOLE SOILS REPORT IS REOUIRED AT FOOTING INSPECTION AND PRIOR TO ANY CONCRETE POUR. PROVIDE COPY OF GEOTECHNICAL ENGINEERS REPORT TO THE BUILDING INSPECTOR. 1,500 PSF soil bearing. PROVIDE COMPACTION REPORT FOR STRUCTURAL FILL 7) ICF MANUFACTURERS INSTALLATION SPECS MUST BE ON SITE AT FOUNDATION INSPECTION. B) THERMAL BARRIER AT ICF FOUNDATIONS. PROVIDE THERMAL BARRIER AT INSIDE FACE OF ICF FOUNDATION WALLS PER IRC SECTION R316.4. READ ALLEGUARD R3O ICF PRODUCT DATAAND ICC-ES EVALUATION REPORT ESR-1269 STAPLED TO FTELD COpy. pER ES REPORT CONDIIONS (AND OWNER FEB 182025 LETTER REPRESENTING NO APPLIANCES IN CRAWL SPACE -- CRAWL SPACE ICF FOUNDATION WALLS MAY NOT REOUTRE COVERTNG). F|ELD VERTFY AS-BU|LT S|TE CONSTRUCTTON. 9) FEBRUARY 18, 2025 OWNER LETTER CONVEYS UNFINISHED BASEMENT AT THIS TIME. ENSURE BASEMENT EGRESS OPENING ADJACENT TO FUTURE'BAR'AND 'RECREATION' LIVING SPACE COMPLIES WITH 2015 IRC SECTION R310. 4FT X2 FT WINDOW OPENING SHEET 2 OF B NON-COMPLIA.NT FOR EMERGENCY ESCAPE AND RESCUE. FIELD VERIFY AS-BUILT ASSEMBLY. 1O)FIRE PROTECTION OF FLOORS ABOVE CRAWL SPACE MUST COMPLYWITH 2015IRC SECTION R302.13. 1 1)FIRE PROTECTION OF FLOORS ABOVE UNFINISHED BASEMENTS MUST COMPLY WITH 2015IRC SECTION R302.13. 12)LOG STRUCTURES: ALL STRUCTURAL LOGS SHALL BE DESIGNED BY A COLORADO LICENSED ARCHITECT OR ENGINEER, AND THE ARCHITECT OR ENGINEER SHALL INSPECT LOGS AFTER COMPLETION OF FRAMING TO CERTIFY THE SIZE, OUALIry AND SPECIES OF LOGS COMPLY WITH ORIGINAL DESIGN REOUIREMENTS, PROVIDE COPY OF REPORT FOR INSPECTOR REVIEW AT FRAME INSPECTION. 13)SEE BASEMENT WALL DETA|LS. 5/8" ANCHOR BOLTS SpECtFtED 14)ENGINEER NOTES, PAGE B OF 8. PLUMBING RISERS REOUIRE SLIP JOINT IN WALLS 15)PROPANE FUEL ryPE SPECIFIED, BASEMENT MECHANICAL ROOM. SEE ATTACHED PROPANE GUIDE. 16)PRE-ENGINEERED ROOF TRUSSES. HAVE ENGINEERING FOR BUILDING INSPECTOR AT FRAME INSPECTION. 17)SEPTIC SYSTEM REVIEW / APPROVALS: PRIOR TO BUILDING INSPECTION & CERTIFICATE OF OCCUPANCY PROVIDE FINAL APPROVAL/SIGN-OFF FROM GARFIELD COUNTY'S PUBLIC HEALTH DEPT. 1B)BLOWER DOOR TEST IS REOUIRED. MUST SUBMIT BLOWER DOOR TEST REPORT TO GARFIELD COUNry COMMUNIry DEVELOPMENT OFFICE PRIOR TO SCHEDULING FINAL BUILDING INSPECTION / C.O. FINAL. 19)PRESCRIPTIVE PATH USING 2O1B IECC TABLE R402.1.2 IS CHOSEN FOR ENERGY COMPLIANCE OF THIS HOME. MANUAL J REPORT SCANNED INTO LASERFICHE. ALL NEW HOMES TO HAVE WHOLE-HOUSE MECHANICAL VENTILATION SYSTEM INSTALLED (2015 IRC TABLE m1507.3.3(1)AND (2) SHOWN ON COVER SHEET. .{ $ N -s N R