HomeMy WebLinkAboutInsulation Certificate
Insulation Certificate
The following insulation was installed by Mountain Peak Insulation LLP:
R-60 hybrid system to all ceilings (6.0 inches) of foam and R-19 unfaced batt insulation
R-30 hybrid system to all 2x6 exterior walls (2.5 inches) of foam and R-13 unfaced batt
insulation without sip panels
Spray foam any holes cut out on sip panels
R-49 Blow in Blanket insulation to lower level ceiling Packed in for better sound reduction
R-30 unfaced batt insulation to 2x8 interior walls
R-21 unfaced batt insulation to garage common wall with 6 mil vapor barrier
R-19 unfaced batt insulation to 2x6 designated interior sound insulation
R-11 unfaced batt insulation to designated 2x4 interior sound walls
R-19 unfaced batt insulation to interior walls in garage area for sound and stairs
Fire foam penetrations, doors and windows
Declarations: I hereby certify that the above insulation was installed in the building at the above location in
Conformance with the current Energy Efficiency standards for the residential building Energy Code
Mountain Peak Insulation LLP.
Mountain Peak Insulation
1113 County Rd. 331
Silt CO. 81652
Tony Chavez
970-366-9824
mountainpeakinsulation@yahoo.com
Builder Info:
Tara Dikides
760-271-5961
tdakides@gmail.com
1212 Panorama Dr
Carbondale CO 81623
Job site:
1212 Panorama Dr
Carbondale CO 81623
Date:03/03/2025