HomeMy WebLinkAboutConditions of Permitc ON DIT N so FP ER MIT BLRE-O3-25-9 107 SIERRA OPERATING LLC ADDING NEW STAIRS OFF AN EXISTING DECK 160 RIVER GLEN ROAD CARBONDALE, CO 81623 1) THEAPPROVED P LANS ARE TO BE ON-SITE FOR INSPECTIONS. 2) SANITARY FAClLlrl ES ARE REOUIRED TO BE PROVIDED FOR WO RKERS 3) A LIST OF REOUIRE D INSPECTIONS WILL BE ATTACHED TO THE PLANS. THE STATE IS TO PERMIT AND APPROVE THE ELECTRICAL WORK RMITS 4) uNDERGROUND UTILITY LOCATES ls THE RESPONSIBILITY OF THE OWNER OR CONTRACTOR.BIIISTHECoLoRADoUTILITLOCATEHoTLINE. 5) ELECTRICAL CODE COMPLIANCE WILL BE DETERMINED BASED ON FIELD INSPECTIONS PERFORMED BY THE STATE ELECTRICAL INSPECTOR' (303) 869-3458 PLEASEHAVETHEINSPECTORSIGNTHEBUILDINGCARDoRPROVIDEWRITTEN DOCUMENTATION OF THE INSPECTIONS. 6) sAFEry GLAZING ls NoT DESIGNATED ON TH CHECKED DURING THE FRAMING AND FINAL E PLANS. SAFEry GLAZING WILL BE INSPECTION. TH E EXISTING THIS REOUIREMENT' (lBc 2406'4) zlnr-nruolNclSnroulnroATTHEBoTToMoFTHESTAIRS. 8) HANDRAIL AND GUARD IS REOUIRED FOR THE STAIRS' GENERIC HANDOUT ATTACHED. 9) THE RISERS ARE LIMITED TO 4" OPENING' 12/29/2016 5 Single FamilY Residential Uncovered Decks and Porches New or existing -2.'- light required v openguardrailsondecksmorethan30inchesaboveqradeorafloorbelowsh have members spaced d; iii;i;?ich-diameter spher-e cannot pass through' Handrail (see deiails below) all Landing same width as stairs Finished grade Guardrail Guardrail required if more than 30" Openings for required ouards on the sldes 6l stair treads shall notallow a4318" diameter sPhere to pass through. Stairwav Notes: i. -stlini,avi shall be not less than 36" in width' i: 5i;i*;i,;iiei strall be not greater thanT 3t4"' a. 5i;iil;i iieioJ snatt have i minimum run of 10"' ;. ih; ffiAth ot nun and the height of Riser shall not varv mo're than 3/8" in the entire run ol the stalr' s. Siairs are required to be illuminated' 6: 6J;; rrserJriermitted il opening is less than 4"' i. Xi""iiiit.oirels tnan 3/+'but iot more than 1 1/4"' ti"iiii""pi&ffi on stait*ays with solid risers' and less than 11". e. dJti;osite materials (example:Trex) may require 4 or more stringers 36'Mi 36" min height Deck Less than 6" dia. 34-38" above nosings 7 314" max. rise 10" min. run from nosing to nosing Open risers less than 4" Stair & Handrail SPecifications stair nosings for non circular handrails'cross section This handout was developed by the Colorado Chapter of the lnternational Code Council as a basic plan submittal under ilr0i5 lnternational Residential Code' lt is not intended to cover all circumstances. Check with your Department of Building Safety for additional requirements' UnaccePtable Handrails Type ll T 3t,,Lt4 131+ Wall or other surface 1 1iz" min. t 1 1lq" - 2" Gripable 1 1lq" - 231+" max. Type I 1-1lz" min Acceptable Handrail Details