HomeMy WebLinkAboutConditions of Permitc ON DIT N so FP ER MIT
BLRE-O3-25-9 107
SIERRA OPERATING LLC
ADDING NEW STAIRS OFF AN EXISTING DECK
160 RIVER GLEN ROAD
CARBONDALE, CO 81623
1) THEAPPROVED P LANS ARE TO BE ON-SITE FOR INSPECTIONS.
2) SANITARY FAClLlrl ES ARE REOUIRED TO BE PROVIDED FOR WO RKERS
3) A LIST OF REOUIRE D INSPECTIONS WILL BE ATTACHED TO THE PLANS. THE STATE
IS TO PERMIT AND APPROVE THE ELECTRICAL WORK
RMITS
4) uNDERGROUND UTILITY LOCATES ls THE RESPONSIBILITY OF THE OWNER OR
CONTRACTOR.BIIISTHECoLoRADoUTILITLOCATEHoTLINE.
5) ELECTRICAL CODE COMPLIANCE WILL BE DETERMINED BASED ON FIELD
INSPECTIONS PERFORMED BY THE STATE ELECTRICAL INSPECTOR' (303) 869-3458
PLEASEHAVETHEINSPECTORSIGNTHEBUILDINGCARDoRPROVIDEWRITTEN
DOCUMENTATION OF THE INSPECTIONS.
6) sAFEry GLAZING ls NoT DESIGNATED ON TH
CHECKED DURING THE FRAMING AND FINAL
E PLANS. SAFEry GLAZING WILL BE
INSPECTION. TH E EXISTING
THIS REOUIREMENT' (lBc 2406'4)
zlnr-nruolNclSnroulnroATTHEBoTToMoFTHESTAIRS.
8) HANDRAIL AND GUARD IS REOUIRED FOR THE STAIRS' GENERIC HANDOUT
ATTACHED.
9) THE RISERS ARE LIMITED TO 4" OPENING'
12/29/2016
5
Single FamilY Residential Uncovered Decks and Porches
New or existing -2.'-
light required v openguardrailsondecksmorethan30inchesaboveqradeorafloorbelowsh
have members spaced d; iii;i;?ich-diameter spher-e cannot pass through'
Handrail (see deiails below)
all
Landing same
width as stairs
Finished grade
Guardrail
Guardrail required if
more than 30"
Openings for required
ouards on the sldes
6l stair treads shall
notallow a4318"
diameter sPhere to
pass through.
Stairwav Notes:
i. -stlini,avi shall be not less than 36" in width'
i: 5i;i*;i,;iiei strall be not greater thanT 3t4"'
a. 5i;iil;i iieioJ snatt have i minimum run of 10"'
;. ih; ffiAth ot nun and the height of Riser shall not
varv mo're than 3/8" in the entire run ol the stalr'
s. Siairs are required to be illuminated'
6: 6J;; rrserJriermitted il opening is less than 4"'
i. Xi""iiiit.oirels tnan 3/+'but iot more than 1 1/4"' ti"iiii""pi&ffi on stait*ays with solid risers' and
less than 11".
e. dJti;osite materials (example:Trex) may require 4
or more stringers
36'Mi
36" min
height
Deck
Less than
6" dia.
34-38" above
nosings
7 314" max. rise
10" min. run
from nosing
to nosing
Open risers
less than 4"
Stair & Handrail SPecifications
stair nosings
for non circular handrails'cross section
This handout was developed by the Colorado Chapter of the
lnternational Code Council as a basic plan submittal under
ilr0i5 lnternational Residential Code' lt is not intended
to cover all circumstances. Check with your Department
of Building Safety for additional requirements'
UnaccePtable Handrails
Type ll
T 3t,,Lt4
131+
Wall or other surface
1 1iz" min.
t 1 1lq" - 2" Gripable
1 1lq" - 231+" max.
Type I
1-1lz" min
Acceptable Handrail Details