HomeMy WebLinkAboutDuct TestCreated with a trial version of Syncfusion PDF library or registered the wrong key Ck here to obtain the valid key. 17477-07rjec/ Retrotec rCloud Quality Assurance Report lecc Duct Test V PASS Your Result: 0.2 CFM/100 ft2 (3 CFM * 100 / 1562 ft2) Target < 3 CFM/100 ft2 Test Information Test Name 236 Limberpine Circle Test Date 2024-08-23 08:56 AM (PDT) Export id S1 WEOSLL Company Name Comfort Air Technician Name Zack Kingery Technician Email zack@comfortairco.com Building Information Address 236 Limberpine Circle,. City Parachute State CO Zip/postal Code 81635 Country United States Year Constructed Not availabte Elevation 4858 ftJ Address Verified? No _'i ' Building Latitude, Longitude Your'location has not been validated. GPS validation Tester location not verified Estimated Distance From Address 5`�\ Not available Test Equipment Fan Model Retrotec 300 Fan Serial Number 3XLFT01575 Pressure Gauge Model Retrotec DM32X Gauge Serial Number e` 500058 E� Environmental Conditions Pre -test Indoor Temperature 85 °F Pre -test Outdoor Temperature 85 OF Wind Speed Unknown Average Barometric Pressure 101.325 kPa Test Dimensions Conditioned Floor Area 1562 ft2 Volume 14058 W retry — Test Results Summary Test Type Flow Reference Pressure Time Averaging Induced Duct Pressure (includes baseline) Nominal Fan Flow Test Results Test Data Set 1 Flow Direction Gauge Location Retrotec rCloud lecc Duct Test 25 Pa 10 seconds -24.93 Pa 3.16CFM@25Pa Depressurize Outside Measured Pressure (Pa) -24.93 Fan Pressure [300 - 18] (Pa) 48.07 Flow (CFM) 3.16 r; re tro= Test Notes No notes entered. Retrotec rCloud Flow Equation Parameters - Factory Default Fan Model Retrotec 300 Fan Serial Number 3XLFT01575 Flow Equation Parameters - B1 Units Used For Flow Parameters in Equation CFM Fan pressure (FP) is the measured fan pressure when using a self -referenced fan or when the room pressure is negative. If using a fan which is not self -referenced, and the room pressure is positive, fan pressure is calculated by subtracting the measured room pressure from the absolute value of the fan pressure. If PrA is greater than 0 or fan is self -referencing: FP = IPrBi - PrA If PrA is less than 0 or fan is self -referencing: FP = PrB Flow calculations are not valid if fan pressure is less than either MF or (K2 x IRPI) FP = tan pressure, RF = room pressure Range N K K1 K2 K3 K4 MF Open 0.5010 28.9100 0.0000 0.4000 0.0000 1 20 74 0.5045 7.0770 0.0000 0.2500 0.0000 1 15 47 0.5000 3.2410 0.0000 0.1000 0.00w - 1 10 29 0.5020 1.1900 0.0000 0.2000 0.0000 1 20 18 0.4990 0.4570 0.0000 0.2500 00 1 25 11 0.4800 0.2080 0.0000 0.2500 `0>00 Q c1'.0000 1 25 7 0.5000 0.0718 0.0000 0.1100 0.0000 1 25 102 0.5900 10.7000 0.0000 0.400Q��� 0.0000 1 100 �G flow=(FP-RPxK1)"x(K+K3xFP)xK4 G5� .� Created with a trial version of Syncfusion PDF library o in vour aonlication. Click here to obtain the valid kev.