Loading...
HomeMy WebLinkAboutConditions of PermitCONDITIONS OF PERMIT BLRE-01-25-9065 REIDER LIVING TRUST New 1,84O sq ft single-family dwelling unit with an 1 ,1O4 sq ft UNCONDITIONED unfinished basement & UNCONDITIONED 480 sq ft crawl space (Adjacent Private Use Garage Storage Shop issued under separate permit BLRE-10-24-8972) 37 49 CR 301, Parachute Morrisania Ranch, Tract 18 - 2407 02300004 1 ) ALL WORK SHALL COMPLY WITH THE 201 5 INTERNATIONAL RESIDENTIAL CODE (I.R.C.) AND 2018 TNTERNATTONAL ENERGY CONSERVATTON CODE (r.E.C.C.) 2) PROPOSED IMPROVEMENTS ARE SUBJECT TO ALL APPLICABLE ITEMS CONTAINED IN THE ATTACH ED "GARFI ELD COU NTY BU I LDI NG REOU I REM ENTS". NU M BER REFERENCES NOTED ON PLANS REFER TO SPECIFIC ITEMS ON THIS LIST. 3) ELECTRICAL PERMITTING AND INSPECTIONS BY COLORADO STATE ELECTRIC BOARD. ELECTRICAL ROUGH-IN APPROVAL IS REOUIRED AT FRAME INSPECTION. ELECTRICAL FINAL APPROVAL IS REOUIRED FOR FINAL INSPECTION & CERTIFICATE OF OCCUPANCY. 4) ALL EXTERTOR LTGHTTNG TO BE DOWNCAST AND SH|ELDED. 5) WILDFIRE MITIGATION RECOMMENDATIONS: SHOULD COMPLY WITH WILDFIRE MITIGATION AND DEFENSIBLE SPACE RECOMMENDATIONS PER COLORADO STATE FOREST SERVICE AND LOCAL FIRE DISTRICT. PLEASE REFER TO THE GARFIELD COUNTY COM M U N ITY DEVELOPM ENT WEBSITE FOR ADDITIONAL I NFORMATION. 6) OPEN HOLE SOILS REPORT IS REOUIRED AT FOOTING INSPECTION AND PRIOR TO ANY CONCRETE POUR. PROVIDE COPY OF GEOTECHNICAL ENGINEERS REPORT TO THE BUILDING INSPECTOR. 1,500 PSF soil bearing. 7) PRE-ENGINEERED ROOF TRUSSES. HAVE ENGINEERING FOR BUILDING INSPECTOR AT TIME OF FRAME INSPECTION. 8) ALL HIGH STRENGTH BOLTING AND FIELD WELDING REOUIRES SPECIAL INSPECTOR. PROVIDE APPROVAL REPORT AT FRAMING INSPECTION. 9) SEPTIC SYSTEM REVIEW / APPROVALS: PRIOR TO BUILDING INSPECTION & CERTIFICATE OF OCCUPANCY PROVIDE FINAL APPROVAUSIGN-OFF FROM GARFIELD COUNry'S PUBLIC HEALTH DEPT. 10) FIRE-RATED WALL DETAIL, SHEET 5 / 6 may (or may not) BE ADEOUATE FOR AS-BUILT PRIVATE USE GARAGE /HOUSE OCCUPANCY SEPARATION. BASED UPON AS-BUILT CONDITIONS AND PROPOSED USES UNDER ISSUED PERMIT BLRE-10-24-8972 -- GARFIELD COUNTY BUILDING INSPECTION DEPARTMENT RETAIN PRIVILEGE TO REOUIRE OWNER TO OBTAIN DEFERRED DETAILS FOR FIRE-SEPARATION STAMPED BY A COLORADO LICENSED ARCHITECT. OWNER BUILDER IS ENCOURAGED TO DISCUSS PROPOSED FIRE- ASSEMBLY DETAIL WITH BUILDING INSPECTOR AT FRAMING INSPECTION. 11) 256 SO FT SECOND FLOOR ',LOFT' ON SHEET 5 / 5 MUST NOT BE USED A5 A FUTURE BEDROOM; SECOND STORY HABITABLE LIVING SPACE CONTAINS NO EMERGENCY ESCAPE & RESCUE OPENING TO YARDS (2015 IRC SECTION R31O) 12) BLOWER DOOR TEST IS REOUIRED. MUST SUBMIT BLOWER DOOR TEST REPORTTO GARFIELD COUNTY COMMUNIry DEVELOPMENT DEPT. OFFICE PRIOR TO SCHEDULING FINAL BUILDING INSPECTION / C.O. FINAL. 13) PRESCRIPTIVE PATH USING 2O1B IECC TABLE R402.1.2 IS IMPLIED BY OWNER BUILDER. HEAT CALCS/ MANUAL J REPORT ATTACHED FOR REFERENCE. ALL NEW HOMES TO HAVE wHoLE-HOUSE MECHANICAL VENTTLATTON SYSTEM TNSTALLED (2015 tRC TABLE m1507.3.3(1)AND (2) SHOWN ON COVER SHEET. 14) THIS SINGLE-FAMILY RESIDENCE WITH UNFINISHED BASEMENT HAS BEEN PROCESSED FOR PRIVATE RESIDENTIAL USE (WITH A PRIVATE USE ONLY GARAGE UNDER SEPARATE PERMIT BLRE-10-24-8972). ANY FUTURE CHANGES IN BUILDING STRUCTURE USE(S)AND OCCUPANCY - SHALL FIRST BE SUBJECT TO NEW APPLICATION REVIEW AND EXAMINED FOR FULL COMPLIANCE WITH LAND USE REGULATIONS / ZONING AND/OR BUILDING CODES IN EFFECT AT TIME OF FUTURE WORK. {tt \.. -\\ -\