HomeMy WebLinkAboutConditions of PermitCONDITIONS OF PER MIT
BLRE-02-25-9082
Rimledge A3, LLC
New Single-family dwelling w/ attached garage
5651 CR 100, Carbondale
Pennig, Lot A-3 - 2391 19400051
1) ALL WORK SHALL COMply W|TH THE 201s TNTERNATTONAL RESIDENTIAL CODE (r.R.C.)AND 2018
I NTERNATIONAL EN ERGY CONSERVATION CODE (I.E.C.C.)
2) PROPOSED IMPROVEMENTS ARE SUBJECT TO ALL APPLICABLE ITEMS CONTAINED IN THE
ATTACHED "GARFIELD COUNry BUILDING REQUIREMENTS". NUMBER REFERENCES NOTED ON
PLANS REFER TO SPECIFIC ITEMS ON THIS LIST.
3) ELECTRTCAL pERM|TTTNG AND TNSPECTTONS BY COLORADO STATE ELECTRIC BOARD. ELECTRICAL
ROUGH-IN APPROVAL IS REOUIRED AT FRAME INSPECTION. ELECTRICAL FINAL APPROVAL IS
REOUIRED FOR FINAL INSPECTION & CERTIFICATE OF OCCUPANCY.
4) ALL EXTERIOR LIGHTING TO BE DOWNCAST AND SHIELDED.
s) WILDFIRE MITIGATION RECOMMENDATIONS: SHOULD COMPLY WITH WILDFIRE MITIGATION AND
DEFENSIBLE SPACE RECOMMENDATIONS PER COLORADO STATE FOREST SERVICE AND LOCAL FIRE
DISTRICT. PLEASE REFER TO THE GARFIELD COUNry COMMUNIry DEVELOPMENTWEBSITE FOR
ADDITIONAL I NFORMATION.
6) OPEN HOLE SOTLS REPORT rS REOUTRED AT FOOTING INSPECTION AND PR|OR TO ANY CONCRETE
POUR. PROVIDE COPY OF GEOTECHNICAL ENGINEERS REPORT TO THE BUILDING INSPECTOR.
1,500 PSF soil bearing 36 inches minimum frost depth per Structural Engineer S.0.01
7) PRE-ENGTNEERED ROOF TRUSSES. HAVE ENGTNEERING FOR BUTLDTNG TNSPECTOR AT TIME OF
FRAME INSPECTION.
B) ALL HtcH STRENGTH BOLTTNG AND FTELD WELDING REOUTRES SPECTAL INSPECTOR. PROVIDE
APPROVAL REPORT AT FRAMING INSPECTION.
9) SEPTIC SYSTEM REVIEW / APPROVALS: PRIOR TO BUILDING INSPECTION & CERTIFICATE OF
OCCUPANCY PROVIDE FINAL APPROVAVSIGN-OFF FROM GARFIELD COUNry'S PUBLIC HEALTH
DEPT.
1 0) BLOWER DOOR TEST tS REOUTRED. MUST SUBMTT BLOWER DOOR TEST REPORT TO GARFIELD
COUNry COMMUNIry DEVELOPMENT DEPT. OFFICE PRIOR TO SCHEDULING FINAL BUILDING
INSPECTION / C.O. FINAL
'l 'l) pREScRtpTtvE PATH usrNG 2018 rEcc TABLE R402.1.2 CHOSEN FOR ENERGY COMPLIANCE OF THIS
HOME. MANUAL J REPORT ATTACHED FOR REFERENCE. ALL NEW HOMES TO HAVE WHOLE-HOUSE
MECHANICAL VENTILATION SYSTEM INSTALLED (2015 IRC TABLE m1507.3.3(1)AND (2) SHOWN ON
COVER SHEET.
$