HomeMy WebLinkAboutInsulation CertificateHomeowner Name / Jobsite Name Home Address Installer / Contractor (sign) Company Name Date Builder (sign) Company Name Date Inspected By (sign if required) Date THERMAL PERFORMANCE—ATTIC BLOWING APPLICATION • In accordance with the chart above, you must install the minimum number of bags per 1,000 sq. ft. of net area for each R-Value listed. • The maximum net coverage must not exceed that specified for each R-Value. • The insulation must be installed at or above the specified installed thickness for each R-Value. • Failure to install the required minimum weight per sq. ft. of insulation at or above the initial installed thickness will result in reduced R-Value. • This product should not be mixed with other blown insulations or the thermal claims will become invalid. DANGER: RECESSED LIGHT FIXTURES—TO PREVENT OVERHEATING, DO NOT INSULATE ON TOP OR WITHIN 3" OF SUCH DEVICES. THIS WARNING DOES NOT APPLY TO TYPE IC LIGHT FIXTURES OR TO FLUORESCENT FIXTURES WITH THERMALLY PROTECTED BALLASTS. MINIMUM MAXIMUM NET SQ. FT. MINIMUM WEIGHT– MINIMUM MINIMUM R-VALUE BAGS PER 1000 SQ. FT. PER BAG COVERAGE POUNDS PER SQ. FT. INSTALLED THICkNESS SETTLED THICkNESS To obtain a Bags per Contents of bag Weight per sq. ft. of Installed insulation Minimum settled insulation thermal resistance 1000 sq. ft. shall not cover installed insulation shall shall not be less than: shall not be less than: (R) of: of net area: more than: (sq. ft.) not be less than: (lbs.) (in.) (in.) 60 31.4 31.9 0.972 22.00 22.00 49 25.2 39.7 0.780 18.50 18.50 44 22.4 44.6 0.695 16.75 16.75 38 19.1 52.5 0.591 14.50 14.50 30 14.9 67.1 0.462 11.75 11.75 26 12.8 77.9 0.398 10.25 10.25 22 10.8 92.9 0.334 8.75 8.75 19 9.3 107.4 0.289 7.75 7.75 13 6.2 161.7 0.192 5.25 5.25 11 5.3 190.5 0.163 4.50 4.50 Builders Statement InsulSafe® SP Fiber Glass Blowing Insulation R-VALUE THICkNESS NET AREA (SQ. FT.)INSULSAFE SP (4)NUMBER OF BAGS USED BATTS/ROLLS (4) CEILINGS WALLS FLOORS OPEN ATTIC APPLICATION CertainTeed Corporation P.O. Box 860 Valley Forge, PA 19482 ASK ABOUT OUR OTHER CERTAINTEED PRODUCTS AND SYSTEMS: Code No. 30-24-298, © 02/11 CertainTeed Corporation ExTERIOR: Roofing • Siding • WindoWS • fence • Railing • TRiM • decking • foundaTionS • PiPe INTERIOR: inSulaTion • gYPSuM • ceilingS Professional: 800-233-8990 Consumer: 800-782-8777 www.certainteed.com/insulation BLACK READ THIS BEFORE YOU BUY What you should know about R-Values. The chart shows the R-Value of this insulation. R means resistance to heat flow. The higher the R-Value, the greater the insulating power. Compare insulation R-Values before you buy. There are other factors to consider. The amount of insulation you need depends mainly on the climate you live in. Also, your fuel savings from insulation will depend upon the climate, the type and size of your house, the amount of insulation already in your house, and your fuel use patterns and family size. If you buy too much insulation, it will cost you more than what you’ll save on fuel. To get the marked R-Value, it is essential that this insulation be installed properly. R-VALUE MINIMUM BAGS PER 1000 SQ. FT. MAXIMUM NET SQ. FT. PER BAG COVERAGE MINIMUM WEIGHT– POUNDS PER SQ. FT. MINIMUM INSTALLED THICkNESS* MINIMUM SETTLED THICkNESS To obtain a thermal resistance (R) of: Bags per 1000 sq. ft. of net area: Contents of bag shall not cover more than: (sq. ft.) Weight per sq. ft. of installed insulation shall not be less than: (lbs.) Installed insulation shall not be less than: (in.) Minimum settled insulation shall not be less than: (in.) 60 31.4 31.9 0.972 22.00 22.00 49 25.2 39.7 0.780 18.50 18.50 44 22.4 44.6 0.695 16.75 16.75 38 19.1 52.5 0.591 14.50 14.50 30 14.9 67.1 0.462 11.75 11.75 26 12.8 77.9 0.398 10.25 10.25 22 10.8 92.9 0.334 8.75 8.75 19 9.3 107.4 0.289 7.75 7.75 13 6.2 161.7 0.192 5.25 5.25 11 5.3 190.5 0.163 4.50 4.50 COvErAGE ChArT—OPEN ATTIC APPLICATION The following thermal performances are achieved at the thicknesses, weights and coverages specified when insulation is installed with pneumatic equipment in a horizontal open blow application. R-Values are determined in accordance with ASTM C687 and C518. Complies with ASTM C764 as Type 1 pneumatic application. *Initial Installed Thickness testing per ASTM C1374 using Unisul VoluMatic III; 3rd gear; 14-inch gate opening; 150 ft. x 3-1/2-inch diameter internally corrugated blowing hose, 12- to 15-foot arc length. COvErAGE ChArT—CLOSEd CAvITy rETrOFIT (wALLS, FLOOrS, CEILINGS) APPLICATION The following thermal performances are achieved at the thicknesses, weights and coverages specified when insulation is installed with pneumatic equipment in sidewalls. Based on a design density of 1.6 pcf/25.6 Kg/m3. REQUIRED OR MINIMUM MAXIMUM NET SQ. FT. MINIMUM WEIGHT– INSTALLED R-VALUE BAGS PER 1000 SQ. FT. PER BAG COVERAGE POUNDS PER SQ. FT. THICkNESS To obtain a Bags per Contents of bag Weight per sq. ft. of Installed insulation thermal resistance 1000 sq. ft. shall not cover installed insulation shall shall not be less than: (R) of: of net area: more than: (sq. ft.) not be less than: (lbs.) (in.) 29 31.2 32.1 0.967 7.25 22 23.7 42.3 0.733 5.50 16 17.2 58.1 0.533 4.00 15 16.1 62.0 0.500 3.75 14 15.1 66.4 0.467 3.50 Manufacturer Insulation Fact Sheet InsulSafe® SP Fiber Glass Blowing Insulation