Loading...
HomeMy WebLinkAboutObservation of Installation1517 Blake avenue, suite 101 Glenwood Springs, CO 81601 970-945-8676  phone 970-945-2555  fax www.hceng.com An Employee-Owned Company March 21, 2024 Garfield County Environmental Health Department 195 14th St, Building A Rifle, CO 81650 RE: Lot 3 Highline Ranch 147 Mustang Mesa Trail, Rifle, Co 81650 OWTS Construction Approval Letter Permit Number SEPT-7619 I visited the construction site on 11/1/23 to review the installation of the onsite wastewater treatment system (OWTS) prior to backfilling the chambers. The contactor, J.Caliber Construction, had left the absorption field open for this site visit and wanted to backfill once the field could be reviewed by myself and the County inspector. The chambers were in place and the piping from the septic tank through the distribution box and to the end of the rows was completed. I was to make a follow up visit once the system was backfilled and the piping out of the house was completed and the distribution box could be tested for even flow. Civil Engineering Land Surveying I made a follow up visit on 2/13/25 to look at the final improvements to the system. The septic tank manways were in place. The cleanout outside the building was now in place as well as the caps on the outfall pipes of the distribution box to provide even flow. The septic field was also backfilled. A flow test was performed from the house sewer line and flow was coming out of the septic tank and evenly distributing to the 3 rows. The OWTS installation for 147 Mustang Mesa trail has been installed to the intent of the 9/12/22 OWTS design drawings and appears to be operating as designed. The only