HomeMy WebLinkAboutConditions of Permitc N D o s F PE M
BtM F-O 3-25-9 1 02 ( Ma n ufactu red Residence)
SEPT-o3-25-9103 (OWTS permit record)BLRE-O3 -25-9104 ("it.-uuitt sarase /covered patio /foundation / unfinished basement)
TOM & NAOMI LAIDLAW
New Manufactured Home praced on permanent foundation --
Unfinished Basement;
site-built attached garage and wark-out covered patio
37836 River Frontage Rd, New Castle
21 81 05300294
MANUFACTURED HOUSES ARE REGULATED & |NSPECTED By coLoRADO DEpr. oF HOUSTNG (C.D.O.H.)AND ALt FACrORY-BUILT RESIDENTIAI srRucruREs rrsralGo rN GARFTETD couNTy MUsr MEETC.D.O.H. GUIDELINES FOR MANUFACTURE EruO TiISTIT.IATION ATTHE JOB SITE.(2o1 8 lEcc 'BtowER DooR TEsrlNG' oltt pnerulses nrren ilvsrA'ATroN sHALLro'r Appry FoR
As cu R R E Nr E N E RGy .o" r.,o" #i#
"+fl
: :t".:?5#3t ; ro r. u= *illl rH E FAcro Ry)
BUILDING FOUNDATION, SITE-BUILTATTACHED GARAGE, AND WALK-OUT COVERED PATIO SHALLCOMPLY WITH 20.I5 I.R.C., AND VNTUTNCiURER'S INSTALLATLOTV REOUIREMENTS.REFER TO PLAN ATTACHMENTS FOR GARFIELD COUNry'S EUILDINC REQUIREMENTS ANDMANUFACTURER'S I NSTALLATION REOUIREMENTS.
wILDFIRE MlrlGAT|oN RECOMMENoartoNs, sHouLD coMply wtrH wtLDFtRE MtlcATtoN ANDDEFENSIBLE SPACE RECOMMENDATIONS COLORADO STATE FOREST SERVICE AND LOCAL FIRE
ijJllJdii$:Elfii^!fiJfi trr canrreLJcouNry corvvurvrrv DEVELo'MENT wEeirre ron
ALL PLUMBING AND GAS PIPING CONNECTIONS MUST BE PERFORMED BYA COLORADO LICENSED
ii!Jr?t,5;,fl)D
ALL ELECTRTCAL coNNrC'o^rs MUSr BE prnronvro ByA coLoRADo LT6ENSED
ALL EXTERIOR LiGHTING TO BE DOWNCASTAI\JD SHiELDED.PROPANE FUEL
'"PE:
SEE PR.PANE GUIDE STAPLED To FIELD coPY.CONTRACTOR / OWNER REP STATES LOT OWNERS INTEND TO HAVE AN UNFINISHED BASEMENT ATBUILDING FINAL / CERTIFICATE OT OCCUPNNCY. SEE LOWER FLOOR PLAN A2B DATED 03-24-2025,AND ALL ACCOMPANYING GARFIET-o couNrv BASEMENT srarvE. sEpARATE BUTLDTNG
'ERMrriii't[tJi".[iri** REVTEW / orHER re ei s'a* APPL' pnron io FrNrsHrNG FUT,RE sAsrve Nr
1)
2)
3)
4)
art
s
s)
6)
7)
8) PRE-ENGINEERED ROOF TRUSSES FOR SITE.BUILT GARAGE STRUCTURE. HAVE ENGINEERING FORBUILDING INSPECTOR AT TIME OF FRAME INSPECTION.9) PRIOR TO FINAL BUILDING INSPECTIOIV A CCNIFICATE OF OCCUPANCY, PROVIDE BUILDINGINSPECTOR WITH FINAL APPROVAL / SIGN-OFF FROM GARFIELD COUNry'S PUBLIC HEALTHDEPARTMENT FoR INSTALLATIoN oF THE oN-srrE wesrewaiER TREATMENT sysrEM.1O) GARFIELD COUNry BUILDING DEPT. INSPECTIONS TO INCLUDE THE FOLLOWING:A. FOOTINGS DESIGNED AT 1,500 PSF, VERIFY 36 INCH V V VUV FROST DEPTH & UFERGROUNDINSTALLED' oPEN HoLE solLS REpoRT REouTRED ar rrnii FoorNG rNspECT,oN. TNCLUDECOMPACTION REPORT FOR STRUCTURAL FILL.B. FOUNDATION
C. SEPTIC SYSTEM CONNECTIOND, PLUMBING/GAS
E. SITE FRAMING, STAIRS, HANDRAILS PER STRUCTURAL ENGINEERS PLANS AND FIELD COPY.F. FINAL INSPECTION & CERTIFICATE OF OCCUPANCY*
"NorE: GARFIELD couNTY REouIRES c.D.o.H. TNSTALLATToN rNSrcNrA To BE AFFT^ED pRroRTO FINAL BUILDING INSPECTION & CERTIFICATE OF OCCUPANCY