HomeMy WebLinkAboutConditions of Permit'l
l
1
I
i
CONDITIONS OF PERMIT
BLRE-03-25-9 117
LAPIS CAPITAL LLC
New Single-family dwelling w/ attached garage
247 Stonefly Dr, Carbondale
CORYELL RANCH, LOT 3
1) ALL WORK SHALL COMPLY WITH THE 2015 INTERNATIONAL RESIDENTIAL CODE (I.R.C.)AND 2018
I NTERNATIONAL EN ERGY CONSERVATION CODE (I.E.C.C.)
2) PROPOSED IMPROVEMENTS ARE SUBJECT TO ALL APPLICABLE ITEIVS CONTAINED IN THE
ATTACHED "GARFIELD COUNTY BUILDING REOUIREMENTS". NUMBER REFERENCES NOTED ON
PLANS REFER TO SPECIFIC ITEMS ON THIS LIST.
3) ELECTRTCAL PERMtTTtNG AND tNSPECTIONS BY COLORADO STATE ELECTRTC BOARD. ELECTRICAL
ROUGH.IN APPROVAL IS REOUIRED AT FRAME INSPECTION. ELECTRICAL FINAL APPROVAL IS
REOUIRED FOR FINAL INSPECTION & CERTIFICATE OF OCCUPANCY.
4) ALL EXTERIOR LIGHTING TO BE DOWNCAST AND SHIELDED.
5) WILDFIRE MITIGATION RECOMMENDATIONS: SHOULD COMPLY WITH WILDFIRE MITIGATION AND
DEFENSIBLE SPACE RECOMMENDATIONS PER COLORADO STATE FOREST SERVICE AND LOCAL FIRE
DISTRICT. PLEASE REFER TO THE GARFIELD COUNTY COMMUNITY DEVELOPMENT WEBSITE FOR
ADDITIONAL IN FORMATION.
6) OPEN HOLE SOTLS REPORT tS REOUTRED AT FOOTING INSPECTION AND PRIOR TO ANY CONCRETE
POUR. PROVIDE COPY OF GEOTECHNICAL ENGINEERS REPORT TO THE BUILDING INSPECTOR.
2,500 PSF soil bearing.
7) PRE-ENGINEERED ROOF TRUSSES. HAVE ENGINEERING FOR BUILDING INSPECTOR AT TIME OF
FRAME INSPECTION.
8) A LOT TMPROVEMENT CERT|FICATE, SEALED BYA COLORADO LTCENSED SURVEYOR, tS REOUTRED AT
FOUNDATION INSPECTION TO VERIFY STRUCTURE IS IN COMPLIANCE WITH MINIMUM SETBACK
REOUIREMENTS / BUILDING ENVELOPE.
9) ANY CONSTRUCTION ACTIVIry THAT CHANGES THE BASIC CHARACTER OR TOPOGRAPHY OF THE
NATURAL LAND LOCATED IN THE 1OO-YEAR FLOODPLAIN MUST FIRST OBTAIN A'FLOODPLAIN
DEVELOPMENT PERMIT' THROUGH GARFIELD COUNTY'S PLANNING DEPT.
10) FIRE-AREA OVER 6,200 SO FT: FIRE-SPRINKLER PERMIT APPLICATION, SPRINKLER PLAN REVIEW AND
ROUGH-IN / FINAL SPRINKLER INSPECTIONS THROUGH CARBONDALE & RURAL FIRE PROTECTION
DISTRICT. CONTACT KARL OLIVER 970-963.2491.
1 1) PLUMBTNG CONTRACTOR SEE P3-1. rF GLYCOL FrRE-SPRINKLER SYSTEM, THEN REDUCED PRESSURE
(R.P.) BACKFLOW PREVENTION DEVICE IS ryPICAL.
12) BLOWERDOORTESTTSREOUTRED. MUSTSUBMTTBLOWERDOORTESTREPORTTOGARFTELD
COUNry COMMUNIry DEVELOPMENT DEPT. OFFICE PRIOR TO SCHEDULING FINAL BUILDING
INSPECTION / C.O. FINAL.
13) PRESCRIPTIVE PATH USING 2018 IECC TABLE R402.1.2 IS CHOSEN FOR ENERGY COMPLIANCE OF
THIS HOME. SEE STAMPED ENGINEERED M.E.P. PLANS STAPLED TO FIELD COPY. ALL NEW HOMES
TO HAVE WHOLE-HOUSE MECHANICAL VENTILATION SYSTEM INSTALLED (2015 IRC TABLE
m'1507.3.3(1)AND (2) SHOWN ON COVER SHEET.